Search results for "Lens implantation"
showing 10 items of 140 documents
Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lens
2007
To assess visual results after symmetrical bilateral implantation of a distance-dominant bifocal diffractive intraocular lens (IOL).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Fifty patients had bilateral implantation of a distance-dominant diffractive bifocal 447D IOL (Acri.Tec GmbH) in a prospective study. Monocular and binocular best corrected distance visual acuities and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 6-month postoperative visit, the mean binocular best corrected distance acuity and…
Long-term follow-up of a multifocal apodized diffractive intraocular lens after cataract surgery.
2007
Purpose To report the long-term performance of the AcrySof ReSTOR SA60D3 intraocular lens (IOL) after cataract surgery. Setting University Hospital Maastricht, Maastricht, The Netherlands. Methods This prospective clinical trial comprised 44 eyes (22 consecutive patients) having cataract surgery with implantation of the ReSTOR IOL. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected near visual acuity, best distance-corrected near visual acuity, spectacle dependence, undesired visual symptoms, patient satisfaction, and incidence of posterior capsule opacification were analyzed 6 months and 3 years postoperatively. Results The mean u…
Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens
2005
Purpose To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindi…
Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator
2013
To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…
Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens
2009
Purpose To determine whether the difference in optic quality between 2 types of phakic intraocular lenses (pIOLs) affects visual quality. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Before implantation of a pIOL for myopia, all eyes had an examination including corrected (CDVA) and uncorrected (UDVA) distance visual acuity testing, corneal endothelial cell count (ECC), and intraocular pressure (IOP) measurement. The postoperative outcomes, determined at least 1 year after surgery, were CDVA; UDVA; contrast sensitivity function under photopic, mesopic, and mesopic with glare conditions; ECC; IOP; keratometry (Scheimpflug photography); and total ocular aberratio…
Fixed Mydriatic Pupil Associated with an Intraocular Pressure Rise as a Complication of the Implant of a Phakic Refractive Lens (PRL)
2013
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in o…
Impact of the line of sight on toric phakic intraocular lenses for hyperopia
2003
We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.
Collagen copolymer posterior chamber phakic intraocular lens for hyperopia correction: three-year follow-up.
2013
Purpose To assess the efficacy, predictability, safety, and stability of the Visian V3 Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) for moderate to high hyperopia. Setting Private clinic, Oviedo, Spain. Design Prospective nonrandomized clinical study. Methods The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, manifest refraction, endothelial cell density, intraocular pressure (IOP), central vault, and adverse events were evaluated for 3 years postoperatively. Results The study comprised 73 eyes of 44 patients. The mean spherical equivalent decreased from +4.84 diopters (D) ± 1.6 (SD) (range +1.00 to +7.75 D) preoperatively to −0.13 ± 0.39 …
Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.
2007
Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…
Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.
2005
To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…