Search results for "Lens"

showing 10 items of 948 documents

Sutureless ciliary sulcus supported intraocular lens with transiridal anchoring haptics.

2003

We report a technique for implanting intraocular lenses (IOLs) in the ciliary sulcus in eyes without capsule support. The IOL design allows it to be implanted without fixation sutures. The lens was implanted in 3 aphakic eyes without capsule support.

AdultMalemedicine.medical_specialtyCiliary sulcusgenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAphakia PostcataractProsthesis DesignFixation (surgical)Ciliary bodyLens Implantation IntraocularOphthalmologymedicineHumansAgedLenses Intraocularbusiness.industryCiliary BodySuture TechniquesCapsuleeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureIntraocular lensesSurgeryFemalesense organsbusinessJournal of cataract and refractive surgery
researchProduct

Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.

2006

ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…

AdultMalemedicine.medical_specialtyCorneal endotheliumBiometrygenetic structuresScheimpflug principleIrisAnterior surfacePhakic intraocular lensRefraction Ocularlaw.inventionLens Implantation IntraocularlawAnterior Eye SegmentCorneaOphthalmologyLens CrystallinemedicineMyopiaPhotographyHumansIris (anatomy)Retrospective StudiesLenses Intraocularbusiness.industrySuture Techniqueseye diseasesLens (optics)Ophthalmologymedicine.anatomical_structureSurgeryFemalesense organsbusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Effects of intraocular cefotaxime on the human corneal endothelium

2001

Abstract Purpose To ascertain whether 0.4 mL of cefotaxime 0.25% applied intracamerally causes toxic alteration of the human corneal endothelium. Methods In this prospective randomized masked study, 66 patients had cataract extraction using phacoemulsification, a frown incision, and implantation of a poly(methyl methacrylate) intraocular lens. This was followed by intraocular injection of 0.4 mL of cefotaxime 0.25% or balanced salt solution (BSS®). Contact specular microscopy and photography were performed preoperatively and 1 to 4 days and 3 months postoperatively. Results In the cefotaxime group, the mean endothelial cell count was 2729 cells/mm 2 ± 474 (SD) preoperatively, 2520 ± 462 cel…

AdultMalemedicine.medical_specialtyCorneal endotheliumCefotaximeAnterior Chambermedicine.medical_treatmentCell CountIntraocular lensBalanced salt solutionCefotaximeDouble-Blind MethodLens Implantation IntraocularCorneaOphthalmologymedicineHumansProspective StudiesAgedCell SizeAntibacterial agentAged 80 and overEndophthalmitisPhacoemulsificationbusiness.industryEndothelium CornealPhacoemulsificationMiddle AgedSensory SystemsCephalosporinsEndothelial stem cellOphthalmologymedicine.anatomical_structureFemaleSurgerysense organsbusinessmedicine.drugJournal of Cataract and Refractive Surgery
researchProduct

Corneal Biomechanical Parameters With Corneoscleral Contact Lenses in Post-Laser In Situ Keratomileusis Eyes

2018

Objective: To evaluate corneal biomechanical parameters wearing corneoscleral contact lenses (CScL) in patients with irregular corneas after laser in situ keratomileusis (LASIK). Methods: Data from patients fitted with CScL because of corneal surface irregularities after complicated LASIK surgery were selected by two eye clinics. Previously and after 1 year of CScL fitting, corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc), and central corneal thickness were evaluated. In addition, visual acuity, subjective comfort, and wearing time CScL were reported. Results: The study comprised 27 eyes. Statistically significant differences were fo…

AdultMalemedicine.medical_specialtyIntraocular pressureCorneal Wavefront AberrationVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityCorneal resistance factorKeratomileusisLASIKCorneaCorneal hysteresis03 medical and health sciences0302 clinical medicineOphthalmologyMyopiamedicineHumansIn patientCorneal surfaceRefractive surgeryIntraocular PressureRetrospective Studiesbusiness.industryLASIKCorneal hysteresisContact Lenses Hydrophiliceye diseasesBiomechanical PhenomenaScleraOphthalmologymedicine.anatomical_structureCorneoscleral contact lensesPatient Satisfaction030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessSclera030217 neurology & neurosurgery
researchProduct

Refractive lens exchange with an array multifocal intraocular lens.

2002

ABSTRACT PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeRefraction Ocularlaw.inventionPostoperative ComplicationsLens Implantation IntraocularlawOphthalmologymedicineMyopiaHumansProspective StudiesIntraocular PressureLenses IntraocularClear lens extractionbusiness.industryMultifocal intraocular lensMiddle AgedRefractioneye diseasesSurgeryLens (optics)OphthalmologyHyperopiaTreatment OutcomePatient SatisfactionSurgeryFemalesense organsmedicine.symptomSafetybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Iris-fixated toric phakic intraocular lens: Three-year follow-up

2006

Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAstigmatismRefraction OcularPhakic intraocular lensOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineHumansMedicineProspective StudiesIntraoperative ComplicationsIntraocular PressureDioptremedicine.diagnostic_testbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresOphthalmoscopyToric lensOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

A 12-month Prospective Study of Tear Osmolarity in Contact Lens Wearers Refitted with Daily Disposable Soft Contact Lenses

2020

SIGNIFICANCE Tear osmolarity has been reported as one of the best diagnostic tests for dry eye disease and its management. Contact lens wear is thought to influence tear homeostasis. Understanding how regular wear of contact lenses and their type affect tear osmolarity is important. PURPOSE The purpose of this study was to assess changes in tear osmolarity and ocular symptoms over a period of 12 months following refitting contact lens wearers with daily disposable contact lenses. METHODS Fifty subjects aged (mean ± SD) 26 ± 4 years were refitted with either silicone-hydrogel (delefilcon A, SiHy, n = 34) or hydrogel (omafilcon A, Hy, n = 16) daily disposable soft contact lenses. Study includ…

AdultMalemedicine.medical_specialtyLower scorelaw.inventionYoung Adult03 medical and health sciences0302 clinical medicinelawProsthesis FittingSurveys and QuestionnairesOphthalmologymedicineHumansOcular Surface Disease IndexProspective StudiesDisposable EquipmentProspective cohort studybusiness.industryOsmolar ConcentrationHydrogelsContact Lenses HydrophilicTear osmolarityeye diseasesLens (optics)Contact lensOphthalmologyTearsTime course030221 ophthalmology & optometryDry Eye SyndromesFemaleDaily disposablesense organsbusiness030217 neurology & neurosurgeryOptometryOptometry and Vision Science
researchProduct

Assessment of corneal thickness and tear meniscus during contact-lens wear

2014

To assess the effect of seven different daily disposable contact lenses upon corneal thickness, as well as upon tear meniscus volume, by using optical coherence tomography (OCT).Thirty-four young healthy subjects wore seven different types of daily disposable soft contact lenses, each for a period of 12h: Delefilcon A, Nelfilcon A, Omafilcon A, Filcon II3, Narafilcon A, Etafilcon A and Hilafilcon B. Central and mid-peripheral corneal thickness and lower tear meniscus volume (TMV) were measured using an OCT device during contact-lens wear at 4-h intervals throughout a 12-h period. Measurements were also recorded without any contact lenses being worn during a day.In the no-lens scenario a sma…

AdultMalemedicine.medical_specialtyMaterials sciencegenetic structuresSurface PropertiesCorneaYoung AdultOptical coherence tomographyOphthalmologyCorneaMyopiamedicineHumansmedicine.diagnostic_testHealthy subjectsGeneral MedicineContact Lenses Hydrophiliceye diseasesContact lensOphthalmologyTear meniscusmedicine.anatomical_structureTearsTearsFemaleDaily disposablesense organsTomography Optical CoherenceOptometryContact Lens and Anterior Eye
researchProduct

Comparison of partial coherence interferometry and ultrasound for anterior segment biometry.

2008

To assess the performance of a partial coherence interferometry (PCI)-based device for the determination of anterior segment biometry.Clinica Centrofama, Cartagena, Murcia, Spain.Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects.Twenty-one eyes (16 subjec…

AdultMalemedicine.medical_specialtyMydriaticsMaterials scienceBiometrygenetic structuresLightAnterior ChamberDiagnostic Techniques OphthalmologicalEyeCorneaLens thicknessOphthalmologyLens CrystallinemedicineHumansBody Weights and Measuresbusiness.industryUltrasoundReproducibility of ResultsCycloplegiaPupileye diseasesSensory SystemsSurgeryOphthalmologyInterferometrySoundPartial coherence interferometrySurgeryFemalesense organsmedicine.symptombusinessPartial coherenceJournal of cataract and refractive surgery
researchProduct

Meibomian glands structure in daily disposable soft contact lens wearers: a one‐year follow‐up study

2020

Purpose To assess the impact of daily disposable soft contact lenses on meibomian gland morphology over a period of 12 months. Methods Forty-one subjects (33 experienced and 8 neophytes) were fitted with either silicone-hydrogel or hydrogel daily contact lenses. The study protocol included four visits: baseline, day-2 for contact lens fit and follow-up measurements, as well as after 6 and 12 months of lens wear. Non-contact infrared meibography images were acquired with Keratograph 5M topographer (www.oculus.de) and analysed with an automated method, which objectively estimates the area of gland atrophy, gland length and width, number of glands and gland irregularity. Protocol at follow-up …

AdultMalemedicine.medical_specialtyOne year follow upMeibomian glandlaw.inventionYoung Adult03 medical and health sciences0302 clinical medicineAtrophylawOphthalmologyHumansMedicineOcular Surface Disease IndexProspective StudiesVision Ocularbusiness.industryOsmolar ConcentrationMeibomian GlandsContact Lenses Hydrophilicmedicine.diseaseeye diseasesSensory SystemsLens (optics)Contact lensOphthalmologymedicine.anatomical_structurePatient SatisfactionTears030221 ophthalmology & optometryFemaleDaily disposablesense organsbusinessEarly phase030217 neurology & neurosurgeryFollow-Up StudiesOptometryOphthalmic and Physiological Optics
researchProduct