Search results for "Lens"

showing 10 items of 948 documents

Chromatic and Spherical Aberration Correction Using Time-Dependent Acceleration and Lens Fields

2003

PhysicsLens (optics)Spherical aberrationAccelerationOpticslawbusiness.industryChromatic scalebusinessInstrumentationlaw.inventionMicroscopy and Microanalysis
researchProduct

In vitro optical quality differences between multifocal apodized diffractive intraocular lenses.

2013

Purpose To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifocal IOL with 3 main foci (trifocal IOL) were evaluated. The optical quality was quantified using the modulation transfer function (MTF) at 7 focal points and for 3.0 mm and 4.5 mm apertures. The through-focus MTF at 10 focal points of the IOLs was also recorded. Results For the 0.0 D and −2.5 D focal points, the bifocal IOL showed the highest MTF values for pupil sizes as well as …

PhysicsLenses IntraocularFocal pointOptics and Photonicsbusiness.industryApertureProsthesis DesignSensory SystemsOptical qualityOphthalmologyOpticsCardinal pointApodizationIntraocular lensesOptical transfer functionSurgeryVisual FieldsbusinessDioptreVision OcularJournal of cataract and refractive surgery
researchProduct

Modulation transfer function of a toric intraocular lens: evaluation of the changes produced by rotation and tilt.

2011

PURPOSE: To evaluate the changes in optical quality when toric intraocular lenses (IOL) are rotated or tilted and to demonstrate that IOL rotation produces an increasing effect of aberrations. METHODS: Modulation transfer function (MTF) and average modulation were used to analyze the image quality of a toric IOL. The axis of the toric IOL was rotated 5°, 10°, 15°, 20°, 25°, and 30° in successive MTF measurements. The tilt values were 0° to 5°, in increments of 1°, plus a tilt of 15°. Pupil diameters of 3 and 5 mm were used. RESULTS: The MTF decay due to aberrations was more sensitive to rotation than tilt. The main decrement in the average modulation, of approximately 50% in both pupils, o…

PhysicsLenses IntraocularOptics and PhotonicsCorneal Wavefront AberrationRotationbusiness.industrymedicine.medical_treatmentIntraocular lensModels TheoreticalRotationArtificial Lens Implant MigrationOptical qualityExponential functionOphthalmologyTilt (optics)OpticsIntraocular lensesModulationOptical transfer functionmedicineHumansSurgerybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

In vitro power profiles of multifocal simultaneous vision contact lenses.

2013

Abstract Purpose To evaluate the power profile of multifocal contact lenses (CLs) using a new technology based on quantitative deflectometry. Methods The Nimo TR1504 was used to analyze the power distribution of multifocal CLs. The CLs under study were: Air Optix Aqua Multifocal Low, Medium and High Addition and Focus Progressives. Three lenses of each model were considered. Results All multifocal CLs showed a power profile characterized by a change toward more positive power values when aperture sizes become smaller. The near refractive addition of the lenses under study was +2.61 D, +1.44 D, +1.30 D and +0.30 D for the Focus Progressives, the Air Optix Aqua Multifocal High, Medium Add and…

PhysicsLightbusiness.industryApertureContact LensesOptical powerGeneral MedicinePresbyopiaEquipment Designmedicine.diseaseDistance correctionlaw.inventionPower (physics)Lens (optics)Equipment Failure AnalysisOphthalmologyRefractometryOpticslawmedicineScattering RadiationbusinessFocus (optics)OptometryNominal power (photovoltaic)Contact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Reconfigurable Shack-Hartmann sensor without moving elements.

2010

We demonstrate wavefront sensing with variable measurement sensitivity and dynamic range by means of a programmable microlens array implemented onto an off-the-shelf twisted nematic liquid crystal display operating as a phase-only spatial light modulator. Electronic control of the optical power of a liquid lens inserted at the aperture stop of a telecentric relay system allows sensing reconfigurability without moving components. Results of laboratory experiments show the ability of the setup to detect both smooth and highly aberrated wavefronts with adequate sensitivity.

PhysicsMicrolensWavefrontLiquid-crystal displaySpatial light modulatorbusiness.industryDynamic rangeAstrophysics::Instrumentation and Methods for AstrophysicsPhysics::OpticsReconfigurabilityOptical powerAtomic and Molecular Physics and Opticslaw.inventionOpticslawImage sensorbusinessOptics letters
researchProduct

Optical module for single-shot quantitative phase imaging based on the transport of intensity equation with field of view multiplexing

2021

We present a cost-effective, simple, and robust method that enables single-shot quantitative phase imaging (QPI) based on the transport of intensity equation (TIE) using an add-on optical module that can be assembled into the exit port of any regular microscope. The module integrates a beamsplitter (BS) cube (placed in a non-conventional way) for duplicating the output image onto the digital sensor (field of view – FOV – multiplexing), a Stokes lens (SL) for astigmatism compensation (introduced by the BS cube), and an optical quality glass plate over one of the FOV halves for defocusing generation (needed for single-shot TIE algorithm). Altogether, the system provides two laterally separate…

PhysicsMicroscopeImage qualitybusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONPhase (waves)Field of viewÒpticaOptometriaMultiplexingAtomic and Molecular Physics and Opticslaw.inventionLens (optics)OpticslawbusinessPhase retrievalBeam splitter
researchProduct

Common-path phase-shifting digital holographic microscopy: A way to quantitative phase imaging and superresolution

2008

We present an experimental setup useful for complex amplitude evaluation and phase image quantification of three-dimensional (3-D) samples in digital holographic microscopy (DHM). It is based on a common-path interferometric configuration performed by dividing the input plane in two contiguous regions and by placing a translation grating near to the Fourier plane. Then, complex amplitude distribution of the sample under test is recovered with phase-shifting standard method obtained by moving the grating using a linear motion stage. Some experimental results of an USAF resolution test are presented for different numerical aperture (NA) microscope lenses. In a second part, the proposed setup …

PhysicsMicroscopebusiness.industryFourier opticsHolographyGratingAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.inventionNumerical apertureLens (optics)OpticslawDigital holographic microscopyElectrical and Electronic EngineeringPhysical and Theoretical ChemistrybusinessImage resolutionOptics Communications
researchProduct

Characterization of a compact low-cost Stokes lens for astigmatism compensation in optical instruments

2020

Variable power cross-cylinder lenses (or Stokes lenses) have been widely known in the literature for decades. In this paper, we describe how to build a low-cost Stokes lens and discuss its calibration and its application to two significant cases. The construction is in virtue of a phoropter’s Risley prism mount for assembling a couple of equal but opposite sign cylindrical lenses (we have selected ± 1.50 D). Thus, variable astigmatic power is achieved by relative rotation of the lenses in opposite directions, and the resulting astigmatic axis is defined by the global rotation of the device. Calibration measurements are performed using an automatic lensmeter (Topcon CL-300) and an aberromete…

PhysicsMicroscopebusiness.industryOptical instrumentAstigmatismDigital microscopemedicine.disease01 natural sciencesAtomic and Molecular Physics and Opticslaw.invention010309 opticsLens (optics)Opticslaw0103 physical sciencesCalibrationmedicinePrismPhoropterElectrical and Electronic EngineeringbusinessEngineering (miscellaneous)Applied Optics
researchProduct

Superresolution digital holographic microscopy for three-dimensional samples.

2009

An approach that allows superresolution imaging of three-dimensional (3-D) samples by numerical refocusing is presented in the field of digital holographic microscopy. Based on the object's spectrum shift produced by tilted illumination, we present a time multiplexing superresolved approach to overcome the Abbe's diffraction limit. The proposed approach uses a microscope in a Mach-Zehnder interferometric architecture with the particularity that the output plane does not coincide with the image plane. Thus, a set of off-axis non-image plane holograms are sequentially recorded for every tilted beam used in the illumination stage. After that and by using simple digital post-processing and nume…

PhysicsMicroscopyMicroscopebusiness.industryHolographyPhysics::OpticsReproducibility of ResultsSignal Processing Computer-AssistedEquipment DesignImage planeImage EnhancementSensitivity and SpecificityAtomic and Molecular Physics and Opticslaw.inventionLens (optics)Equipment Failure AnalysisInterferometryOpticsImaging Three-DimensionallawMicroscopyDigital holographic microscopybusinessDigital holographyOptics express
researchProduct

Extinction law classification and lens redshift estimate by means of the principal component analysis

2007

Aims. We propose a method based on the Principal Component Analysis (PCA) to classify and estimate the redshift of an extinction law in a distant gravitational lens galaxy. Such extinction laws are very poorly known and an efficient method to characterize them is badly needed. Methods. We first compute the principal axes of an exhaustive collection of redshifted theoretical extinction laws. Then, we project on these new axes the extinction law we wish to classify. The position of its projection among those redshifted extinction laws from the collection allows us to characterize it and to estimate its redshift. Results. Monte Carlo simulations show that the method is efficient and relatively…

PhysicsMonte Carlo methodAstronomy and AstrophysicsAstrophysics::Cosmology and Extragalactic AstrophysicsAstrophysicsRedshiftGalaxyGravitational lensSpace and Planetary ScienceExtinction (optical mineralogy)LawPrincipal component analysisProjection (set theory)Principal axis theoremAstronomy & Astrophysics
researchProduct