Search results for "Lens"
showing 10 items of 948 documents
3D digitization of transparent objects by polalization techniques in IR & by triangulation in UV
2011
Two non-conventional methods for the 3D digitization of transparent objects via non-contact measurement are reported in this thesis. 3D digitization is a well acknowledged technique for opaque objects and various commercial solutions based on different measurement approaches are available in the market offering different types of resolution at different prices. Since these techniques require a diffused or lambertian surface, their application to transparent surfaces fails. Indeed, rays reflected by the transparent surface are perturbed by diverse inter-reflections induced by the refractive properties of the object. Therefore, in industrial applications like quality control, the transparent …
The effect of fractal contact lenses on peripheral refraction in myopic model eyes.
2014
Purpose: To test multizone contact lenses in model eyes: Fractal Contact Lenses (FCLs), designed to induce myopic peripheral refractive error (PRE). Methods: Zemax ray-tracing software was employed to simulate myopic and accommodation-dependent model eyes fitted with FCLs. PRE, defined in terms of mean sphere M and 90–180 astigmatism J180, was computed at different peripheral positions, ranging from 0 to 35 in steps of 5, and for different pupil diameters (PDs). Simulated visual performance and changes in the PRE were also analyzed for contact lens decentration and model eye accommodation. For comparison purposes, the same simulations were performed with another commercially available conta…
Phake Intraokularlinsen
2004
Phakic intraocular lenses (PIOLs), which are located closer to the eye's nodal points than the anterior corneal surface, can provide superior optical quality for higher corrections because of retention of normal prolate corneal asphericity and larger effective optical zones. Improvements in the material and design of phakic intraocular lenses and their insertion devices combined with advances in the understanding of the anatomical and physiological interactions of the PIOLs with intraocular structures, have increased safety and efficacy. Safety of these implants over the long term remains a concern, but in several situations PIOLs are the refractive correction of choice. The purpose of this…
Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism.
2020
Aim To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens (IOL) in eyes with low degrees of corneal astigmatism. Methods Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL (FineVision PODFT, PhysIOL s.a., Liege, Belgium) were enrolled. Phacoemulsification with femtosecond laser, capsular tension ring insertion and intraoperative aberrometry were performed in all cases. All IOLs used showed a cylinder power of 1.00 D. Main outcome measures were refractive error and corrected-distance visual acuity (CDVA) and uncorrected-distance visual acuity (UDVA) values. Eyes were evaluated at 4mo post-su…
Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes
2008
Contrast Test chart at distance and near under 3 luminance levels (85.0 cd/m 2 , 5.0 cd/m 2 , and 2.5 cd/m 2 ) before and after RLE with bilateral AcrySof ReSTOR IOL implantation in 30 hyperopic eyes with presbyopia and low astigmatism (%1.0 diopter). Results after surgery were compared with those before surgery. RESULTS: Six months postoperatively, the mean residual spherical equivalent refractive error was 0.21 diopter G 0.19 (SD). The best corrected distance and near visual acuities were comparable to those before surgery. For distance vision, the safety index was 1.02 and the efficacy index was 0.91. For near vision, the values were 1.04 and 1.02, respectively. There were no statistical…
Modelling genetic regulation of growth and form in a branching sponge
2008
We present a mathematical model of the genetic regulation controlling skeletogenesis and the influence of the physical environment on a branching sponge with accretive growth (e.g.Haliclona oculataorLubomirskia baikalensis). From previous work, it is known that high concentrations of silicate induce spicule formation and upregulate thesilicateingene. The upregulation of this gene activates locally the production of spicules in the sponge and the deposition of the skeleton. Furthermore, it is known that the expression of the geneIroquoisinduces the formation of an aquiferous system, consisting of exhalant and inhalant pores. We propose a model of the regulatory network controlling the separa…
Surgical management of acute angle-closure glaucoma after toric implantable contact lens implantation
2006
A case of pupillary block after implantation of an implantable contact lens (ICL) is reported, and surgical management and prevention are discussed. In a myopic patient, the best corrected visual acuity in the right eye was 20/50 with -15.50 -3.00 x 175. After uneventful implantation of an ICL, painful acute glaucoma developed with an intraocular pressure beyond measurable values. Apparent anterior vaulting of the ICL suggested a sizing problem. In a situation of a mid-wide dilated pupil, immediate explantation of the ICL was performed. Then, using a preoperative iris photography as guidance, an anterior chamber iris-claw toric phakic intraocular lens was implanted. On postoperative examina…
Images perceived after chromatic or achromatic contrast sensitivity losses.
2010
Purpose. We simulate how subjects with losses in chromatic and achromatic contrast sensitivity perceive colored images by using the spatiochromatic corresponding pair algorithm. Methods. This is a generalized version of the algorithm by Capilla et al. (J Opt Soc Am (A) 2004;21:176 –186) for simulating color perception of color deviant subjects, which incorporates a simple spatial vision model, consisting of a linear filtering stage, with a band-pass achromatic filter and two low-pass chromatic ones, for the red-green and blue-yellow mechanisms. These filters, except for the global scaling, are the subject’s contrast sensitivity functions measured along the cardinal directions of the color s…
Intraocular lens centration and stability: efficacy of current technique and technology
2008
Purpose of review The manuscript presents a review of recently published studies analyzing different methodologies to assess centration and stability of intraocular lenses after implantation. Recent findings Considering that there is no current gold standard for centration and stability of intraocular lenses after implantation, we have summarized the different techniques used clinically for intraocular lenses centration and stability estimation. We have described the use of Scheimpflug imaging, the anterior segment optical coherence tomography and photography analysis used for lens position estimation. Techniques used to assess lens rotation are based on image analysis on digital retroillum…
Pētera šmita vēstule latviešu un lietuviešu folkloristam, etnogrāfam Eduardam Volteram
1912
Vēstulē P. Šmits runā par latviešu mitoloģiju, tautas dziesmām, piemin A. Bīlenšteina darbu par latviešu koka celtnēm, lietuviešu valodnieku K. Būgu, kā arī interesi par citu tautu folkloru, priecātos par E. Voltera viedokli par saviem rakstiem, lūdz atsūtīt veco katoļu Katehismu.