Search results for "Lenses"

showing 10 items of 294 documents

Wavefront holoscopy: application of digital in-line holography for the inspection of engraved marks in progressive addition lenses

2014

Progressive addition lenses (PALs) are engraved with permanent marks at standardized locations in order to guarantee correct centering and alignment throughout the manufacturing and mounting processes. Out of the production line, engraved marks provide useful information about the PAL as well as act as locator marks to re-ink again the removable marks. Even though those marks should be visible by simple visual inspection with the naked eye, engraving marks are often faint and weak, obscured by scratches, and partially occluded and difficult to recognize on tinted or antireflection-coated lenses. Here, we present an extremely simple optical device (named as wavefront holoscope) for visualiza…

In line holographyComputer scienceHolographyNormal DistributionBiomedical EngineeringHolographyDiagnostic Techniques OphthalmologicalEngravinglaw.inventionBiomaterialsAutomationImaging Three-DimensionalOpticslawMaterials TestingImage Processing Computer-AssistedHumansComputer visionLensesProgressive addition lensesWavefrontLaser engravingbusiness.industryLasersReproducibility of ResultsEquipment DesignAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsVisualizationEyeglassesvisual_artCalibrationvisual_art.visual_art_mediumArtificial intelligencebusinessAlgorithmsDigital holographyJournal of Biomedical Optics
researchProduct

Visual and optical performance with hybrid multifocal intraocular lenses

2010

During the past years, the wish to become independent of spectacles has been growing among cataract and presbyopic patients due to many factors, such as the increase in near visual demands, the aesthetic need for a spectacle-free image and ageing of refractive surgery patients, among others. This review assesses recently published studies that analyse visual and optical performance through different metrics of eyes implanted with multifocal intraocular lenses (IOLs), particularly hybrid IOL designs. The published evidence suggests that hybrid multifocal IOLs provide very good outcomes in a number of visual and optical performance parameters. Patients implanted with this type of IOL obtain a…

Intraocular LensesOptical PerformanceVisual acuitygenetic structuresCompensation Comparisonmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityMethodKeratomileusislaw.inventionGlareLensTratamiento médicoSensitivitylawRefractive surgeryMedicineContrast (vision)MonovisionPostoperative Periodmedia_commonVistaLenses IntraocularMultifocalsGlare (vision)Equipment DesignRefractive ErrorsLens (optics)Bilateral ImplantationApodized Diffractive IolOftalmologíamedicine.symptommedicine.medical_specialtyIn-Situ KeratomileusisRefractivemedia_common.quotation_subjectHigh-Order AberrationsContrast SensitivityOphthalmologyAberrometryClinical-OutcomesHumansRetinal StraylightDepth Perceptionbusiness.industryAberrometryMultifocal intraocular lensContrasteye diseasesOphthalmologyOptometrysense organsbusinessOptometry
researchProduct

Acute endothelial failure after cosmetic iris implants (NewIris®)

2011

We report a case of an acute endothelial failure after the implantation of a new cosmetic, colored, artificial iris diaphragm implant called NewIris(®). A 21-year-old woman came to us complaining of progressive loss of vision and pain after NewIris lenses had been implanted. Decreased visual acuity, corneal edema, and increased intraocular pressure in both eyes appeared only 3 weeks after the surgery. The lenses were removed as soon as possible but had already severely affected the endothelial cell count. NewIris implants are an alternative to cosmetic contact lenses, but they are not as safe as other phakic anterior chamber intraocular lenses, nor are they a good option for the patient.

Intraocular pressuremedicine.medical_specialtygenetic structuresbusiness.industryCase Reportendothelial failureNewIrisEndothelial cell counteye diseasescosmetic iris implantsSurgeryOphthalmologymedicine.anatomical_structureCorneal edemaIntraocular lensesOphthalmologyDecreased Visual AcuitymedicineImplantsense organsIris (anatomy)businessClinical Ophthalmology (Auckland, N.Z.)
researchProduct

Posterior chamber phakic intraocular lenses after penetrating keratoplasty.

2009

Purpose To evaluate the efficacy, predictability, and safety of a phakic posterior chamber intraocular Collamer lens (ICL) after penetrating keratoplasty (PKP). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods A myopic or toric ICL was implanted after PKP in eyes unable to wear glasses or contact lenses and for which corneal laser surgery was contraindicated. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error, and endothelial cell count were recorded preoperatively and 24 months postoperatively. Results Preoperatively, the 15 eyes had myopia from −2.00 to −17.00 diopters (D) or astigmatism from −1.50 to −7.00 D. …

Laser surgeryAdultMaleRefractive errormedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensCell CountAstigmatismPhakic intraocular lensSafety indexPostoperative ComplicationsLens Implantation IntraocularRefractive surgeryOphthalmologymedicineMyopiaHumansProspective StudiesDioptrebusiness.industryEndothelium CornealAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment OutcomeSurgeryFemalesense organsbusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.

2008

Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …

Laser surgeryMalemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituAcrylic ResinsVisual AcuityKeratomileusisIntraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineMyopiaHumansProspective StudiesDioptreAgedLenses Intraocularmedicine.diagnostic_testbusiness.industryCorneal TopographyMultifocal intraocular lensMiddle AgedCorneal topographymedicine.diseasePrognosiseye diseasesOphthalmologyHyperopiaFemaleLasers Excimersense organsmedicine.symptombusinessFollow-Up StudiesAmerican journal of ophthalmology
researchProduct

Solvent for removing silicone oil from intraocular lenses: experimental study comparing various biomaterials.

2000

Abstract Purpose To evaluate the effectiveness of a perfluorocarbon—perfluorohexyloctane (PFHO)—in removing silicone oil from different intraocular lenses (IOLs) and determine whether any removal technique enhances the removal of silicone oil. Methods Six IOL materials were analyzed: standard poly(methyl methacrylate) (PMMA), heparin-surface-modified (HSM) PMMA, AcrySof, 2 polyHEMAs with different water contents, and a second-generation SLM-2 silicone. One or 2 μL of a highly viscous silicone oil (5700 cs) was applied to the center of each IOL optic. Perfluorohexyloctane (2 mL) was then used to remove the silicone oil by 1 of 3 techniques: immersion of the IOL in PFHO; irrigation of the sil…

Lens materialsmedicine.medical_specialtyMaterials scienceSurface Propertiesmedicine.medical_treatmentIntraocular lensBiocompatible Materialschemistry.chemical_compoundSiliconemedicineHumansPolymethyl MethacrylateSilicone OilsLenses IntraocularFluorocarbonsComputerized analysisBiomaterialAdhesivenessReproducibility of ResultsSensory SystemsSilicone oilSurgerySolventOphthalmologychemistryIntraocular lensesSolventsMethacrylatesSurgeryBiomedical engineeringJournal of cataract and refractive surgery
researchProduct

Compression forces of haptics of selected posterior chamber lenses

1997

Abstract Purpose: To compare the compressive forces of the haptics of different intraocular lens (IOL) models and analyze the observed differences. Setting: Central Hospital of Central Finland and University of Jyvaskyla, Jyvaskyla, Finland. Methods: The haptics of 28 IOL models were compressed to a diameter of 9.0 mm. The compression forces were measured at 0.5 mm intervals. The conclusions were verified by numerical simulations of mechanical models of the lenses. Results: The measured forces varied between 100 and 601 mg at a diameter of 11.0 mm, 206 and 1057 mg at a diameter of 10.0 mm, and 315 and 2094 mg at a diameter of 9.0 mm. The slopes of the force curves of the three-piece lenses …

Lenses IntraocularMaterials scienceCompressive Strengthbusiness.industryMechanical modelsmedicine.medical_treatmentIntraocular lensCompression (physics)Sensory SystemsForce curveslaw.inventionLens (optics)OphthalmologyOpticsCompressive strengthLens Implantation IntraocularlawmedicineSurgerybusinessBiomedical engineeringHaptic technologyJournal of Cataract and Refractive Surgery
researchProduct

Compression forces of haptics of freely rotating posterior chamber intraocular lenses.

1998

Abstract Purpose: To measure the compressive forces of the haptics of 28 intraocular lens (IOL) models for different modes of compression and compare the results of two types of measurements. Setting: Department of Ophthalmology, Central Hospital of Central Finland, Jyvaskyla, Finland. Methods: The haptics of 28 types of IOLs were compressed to a diameter of 9.0 mm between curved anvils. The compression forces in the plane of compression (i.e., in the plane of the optics) were measured at 0.5 mm intervals. During compression, the optics and the haptics were free to rotate with respect to the anvils. The results were compared with those of earlier measurements in which the optics were held f…

Lenses IntraocularMaterials scienceCompressive Strengthbusiness.industryPlane (geometry)medicine.medical_treatmentStiffnessIntraocular lensCompression (physics)RotationSensory Systemslaw.inventionLens (optics)OphthalmologyOpticsLens Implantation IntraocularlawmedicinePerpendicularSurgerymedicine.symptombusinessHaptic technologyJournal of cataract and refractive surgery
researchProduct

Determination of scattering in intraocular lenses by spectrophotometric measurements.

2014

This study presents a method for measuring scattering in explanted intraocular lenses (IOLs). Currently, determining scattering in IOLs is usually performed by Scheimpflug cameras and the results are expressed in the units used by this apparatus. The method we propose uses a spectrophotometer and this makes it possible to measure the total transmission of the IOL by using an integrating sphere; the direct transmission is determined by the double-beam mode. The difference between these two transmissions gives a value of the scattering in percentage values of light lost. In addition, by obtaining the spectral transmission curve, information about the most scattered wavelengths is also obtaine…

Lenses IntraocularMaterials scienceLightScatteringbusiness.industryScheimpflug principleBiomedical EngineeringAtomic and Molecular Physics and OpticsLight scatteringElectronic Optical and Magnetic MaterialsBiomaterialsCuvetteWavelengthOpticsIntegrating sphereSpectrophotometryMaterials TestingTransmittanceScattering RadiationbusinessDioptreJournal of biomedical optics
researchProduct

Effect of Decentration on the Optical Quality of Two Intraocular Lenses

2016

To analyze the effect of decentration on the optical quality of two diffractive-refractive intraocular lenses, a bifocal and a trifocal, when displaced laterally (horizontal direction) from the center.The AT LISA 809M IOL (+3.75 D add) with two main foci and the AT LISA tri 839MP intraocular lens with three main foci (Carl Zeiss Meditec AG, Jena, Germany) were analyzed. The optical quality of the intraocular lenses was measured with the PMTF (power and modulation transfer function [MTF] measurement for refractive and diffractive intraocular lenses) optical bench (Lambda-X, Nivelles, Belgium). The optical quality of the lenses was evaluated by the MTF at different object vergences, the avera…

Lenses IntraocularOptics and Photonicsbusiness.industryVision TestsProsthesis DesignRefraction OcularRefractionOptical quality03 medical and health sciencesOphthalmologyOcular physiology0302 clinical medicineOpticsIntraocular lenses030221 ophthalmology & optometryHumansProsthesis designOptometryVision testbusinessVision Ocular030217 neurology & neurosurgeryGeologyOptometryOptometry and Vision Science
researchProduct