Search results for "Lenses"
showing 10 items of 294 documents
Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK
2018
ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…
Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
2011
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…
Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.
2014
Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …
Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation
2011
PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…
Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens.
2001
The purpose of the present work was to study the effect on visual performance of wearing disposable soft tinted contact lenses for cosmetic purposes. Parameters such as contrast sensitivity (Vistech 6000), colour vision (Farnsworth-Munsell 100-Hue colour test), visual fields (static Goldmann perimetry) and subjective vision (what the wearer feels while wearing the lenses) were studied under different illumination levels in order to check for possible vision losses while wearing these contact lenses at low illumination levels. Sixteen emmetropic subjects were fitted consecutively with seven pairs of different colour lenses (Optima Colors lenses by BauschLomb), and the experimental parameters…
Changes in Accommodation and Ocular Aberration With Simultaneous Vision Multifocal Contact Lenses
2012
Objective: The aim of this study was to evaluate ocular aberration changes through different simultaneous vision multifocal contact lenses (CLs). Methods: Eighteen young-adult subjects with a mean age of 29.8 +/- 2.11 years took part. Changes in accommodative response, spherical aberration (C-4(0)), horizontal coma (C-3(1)), vertical coma (C-3(-1)), and root mean square (RMS) of higher-order aberrations (HOAs, third to sixth orders) were evaluated. Measurements were obtained with a distance-single vision CL and 2 aspheric multifocal CLs of simultaneous focus center-near design (PureVision Low Add and PureVision High Add) for 2 accommodative stimuli (-2.50 and -4.00 D). All measurements were…
Accommodative Functions with Multifocal Contact Lenses: A Pilot Study
2011
PURPOSE: To evaluate accommodative response and facility in presbyopic patients fitted with several types of simultaneous-image multifocal contact lenses (CLs). METHODS: Six presbyopic patients, unadapted wearers of simultaneous-image bifocals, were fitted with the Focus Progressives and the low- and high-addition Pure Vision simultaneous vision multifocal CLs. Each individual wore each of the three types of lenses in successive random order. Accommodative response, accommodative facility, visual acuity, and contrast sensitivity at distance and near were evaluated in all cases. A control group of eight non-presbyopic patients was also studied. RESULTS: The mean age was 28.6 +/- 2.72 and 51.…
Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantation
2000
BACKGROUND—Standard examination of contrast sensitivity under conditions of glare disability is performed with incandescent light. A new halogen glare test that simulates glare as seen with oncoming vehicle headlights was used to measure glare disability in patients implanted with multifocal and monofocal intraocular lenses (IOLs). METHODS—28 patients with an average age of 69 years (SD 12 years) were implanted with a monofocal IOL (SI-40NB, Allergan) and 28 patients with an average of 66 years (12 years) were implanted with a refractive multifocal IOL (Array-SA-40N, Allergan). All patients were followed for 5 months postoperatively. Contrast sensitivity at four spatial frequencies (3, 6, 1…
Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.
2015
Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…
Posterior chamber phakic intraocular lenses to correct high myopia: A comparative study between Staar and Adatomed models
2001
ABSTRACT PURPOSE: To determine the feasibility of using posterior chamber phakic intraocular lenses (PIOLs) to treat high myopia, comparing two different models, Staar and Adatomed. METHODS: Twenty-four eyes from 12 patients were studied prospectively. A phakic Staar IOL was implanted in one eye of each patient, and the other eye received a phakic Adatomed IOL. Patients with uveitis or ocular trauma prior to ocular surgery, diabetic retinopathy, or capsular pseudoexfoliation were excluded. The mean preoperative spherical equivalent refraction was -16.00 ± 5.05 D for the Staar group and -15.39 ± 2.83 D for the Adatomed group. Average follow-up was 32.4 months (range, 19 to 46 mo) for the Ada…