Ultraviolet radiation at Mediterranean latitudes and protection efficacy of intraocular lenses.

2011

Summary Purpose After determining the mean intensity of ultraviolet radiation to which the human eye is exposed at Mediterranean latitudes, this data is used to evaluate the efficacy of the ultraviolet filters incorporated into various intraocular lenses. Methods Ultraviolet radiation measured at Mediterranean latitudes was used as a reference for the theoretical calculation of the amount of radiation to which the human eye is exposed. The spectral transmission curve from 290 to 380 nm was measured for 10 IOLs using a UV/VIS Perkins-Elmer Lambda 800 spectrometer. Results At Mediterranean latitudes, at sea level, with a mean annual solar irradiation of 50 j/cm 2 , the human eye receives a qu…

Materials sciencegenetic structuresUltraviolet Raysmedicine.medical_treatmentIntraocular lensRadiationmedicine.disease_causelaw.inventionOpticsRadiation ProtectionlawLens CrystallinemedicineAnimalsHumansIrradiationLenses Intraocularbusiness.industryMediterranean RegionAlbedoeye diseasesLens (optics)OphthalmologyWavelengthmedicine.anatomical_structureSunlightHuman eyesense organsRabbitsbusinessUltravioletJournal francais d'ophtalmologie
researchProduct

OCT applications in contact lens fitting

2022

Optical Coherence Tomography (OCT) is a noninvasive, high-speed, high-resolution imaging technology based in the Michaelson interferometry. A near-infrared light beam is used to register the intensity variations for the light backscattered on each sample layer. Due to the high repeatability on corneal measurements, spectral domain OCT (SD-OCT) is the gold standard when talking about in vivo, non-invasive anterior segment imaging. Changes in the morphology of various ocular surfaces such as the cornea, conjunctiva, limbus or tear film with soft (SCL), rigid, corneal or scleral lens (SL) wear can be described by OCT measurements. For instance, evaluation of the corneoscleral region is essenti…

Materials sciencegenetic structuresmedicine.medical_treatmentlaw.inventionCorneaOptical coherence tomographyScleral lenslawCorneamedicineHumansmedicine.diagnostic_testOrthokeratologyGeneral MedicineRepeatabilityContact Lenses Hydrophiliceye diseasesContact lensLens (optics)OphthalmologyInterferometrymedicine.anatomical_structureTearssense organsConjunctivaTomography Optical CoherenceOptometryBiomedical engineeringContact Lens and Anterior Eye
researchProduct

Opportunities and threats to contact lens practice: A global survey perspective

2021

Aim: To understand the views of contact lens (CL) practitioners across the globe regarding what they perceive as opportunities and threats in CL practice. Methods: A self-administered anonymised questionnaire, constructed in English and translated in six more languages, was distributed through reputed international professional bodies and academic institutions worldwide. The questionnaire included items on demographic characteristics, type of practice, and questions designed to explore practitioners’ perspective on the future of their CL practice over the next five years. Results: A total of 2408 valid responses were analysed. Multifocal CLs for presbyopia, CLs for myopia control, use of da…

Medical educationUniversitiesContact LensesPerspective (graphical)GlobeContact lens practicePresbyopiaGeneral MedicinePresbyopiamedicine.diseaseBiocompatible materialContact lensOphthalmologymedicine.anatomical_structureCLs upper limitsOpportunitieSurveys and QuestionnairesMyopiamedicineHumansDaily disposablePsychologyThreatOptometry
researchProduct

Anterior Capsule Opening Contraction and Late Intraocular Lens Dislocation after Cataract Surgery in Patients with Weak or Partially Absent Zonular S…

2021

Background and Objectives: To evaluate anterior capsule opening (ACO) contraction and late intraocular lens (IOL) dislocation after cataract surgery in patients with weak or partially absent zonular support and assess methods of reducing these complications. Materials and Methods: For this prospective study, we enlisted cataract surgery patients in our hospital with preoperative diagnoses of weak zonules. All patients received phacoemulsification surgery with implantation of a hydrophobic acrylic IOL and capsular tension ring (CTR). ACO reductions were measured for six months after enrolment. Data on late IOL dislocations were collected five years after enrolment of the last patient. Result…

Medicine (General)medicine.medical_specialtyIntraocular Lens Dislocationgenetic structuresmedicine.medical_treatmentIntraocular lensAfter cataractArticleCataractlate intraocular lens dislocationR5-920Postoperative ComplicationsLens Implantation IntraocularmedicineHumansProspective StudiesProspective cohort studyweak zonules; anterior capsule opening reduction; late intraocular lens dislocation; capsular tension ringReduction (orthopedic surgery)Lenses IntraocularPhacoemulsificationbusiness.industryweak zonulescapsular tension ringGeneral MedicinePhacoemulsificationCataract surgeryLens Subluxationmedicine.diseaseComorbidityeye diseasesSurgeryanterior capsule opening reductionsense organsbusinessMedicina
researchProduct

Design, Calibration, and Application of a Robust, Cost-Effective, and High-Resolution Lensless Holographic Microscope

2022

Lensless holographic microscope (LHM) is an emerging very promising technology that provides high-quality imaging and analysis of biological samples without utilizing any lens for imaging. Due to its small size and reduced price, LHM can be a very useful tool for the point-of-care diagnosis of diseases, sperm assessment, or microfluidics, among others, not only employed in advanced laboratories but also in poor and/or remote areas. Recently, several LHMs have been reported in the literature. However, complete characterization of their optical parameters remains not much presented yet. Hence, we present a complete analysis of the performance of a compact, reduced cost, and high-resolution LH…

Microscopyin-line holographic microscopy; digital holography; Gabor holography; lensless microscope; digital image processing; medical and biological imaging; microscope characterizationCost-Benefit Analysisin-line holographic microscopyChemical technologyHolographyTP1-1185microscope characterizationÒpticaOptometriadigital image processingdigital holographyBiochemistryArticleAtomic and Molecular Physics and OpticsAnalytical ChemistryGabor holographylensless microscopeCalibrationmedical and biological imagingElectrical and Electronic EngineeringInstrumentationLenses
researchProduct

Retinal straylight in patients with monofocal and multifocal intraocular lenses

2007

Purpose To determine the differences in retinal straylight perceived by patients with monofocal intraocular lenses (IOLs) and patients with multifocal IOLs. Setting Vissum-Instituto de Oftalmologico de Alicante, Alicante, Spain. Methods In this prospective study, contrast sensitivity and retinal straylight were measured prospectively 6 months postoperatively in 67 eyes of 40 patients with a monofocal or multifocal IOL. In the monofocal group, a ThinOptX IOL (ThinOptX, Inc.) was implanted in 12 eyes and an Acri.Smart 48 S IOL (Acri.Tec) in 20 eyes. In the multifocal IOL group, a ReZoom IOL (Advanced Medical Optics) was implanted in 13 eyes and a ReSTOR IOL (Alcon Laboratories) in 22 eyes. Re…

Miosismedicine.medical_specialtyLightPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectIntraocular lensRetinaPupilGlareContrast Sensitivitychemistry.chemical_compoundLens Implantation IntraocularOphthalmologymedicineHumansScattering RadiationContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryGlare (vision)RetinalPhacoemulsificationMiddle AgedMultifocal intraocular lensequipment and supplieseye diseasesSensory SystemsOphthalmologychemistryOptometrySurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Imaging quality of multifocal intraocular lenses: automated assessment setup

2012

[EN] Purpose: A new technique for the assessment of the optical quality of multifocal intraocular lenses (MIOLs) under monochromatic and polychromatic illumination is presented. Methods: The system provides, in a totally automated procedure, the modulation transfer function (MTF) of the lens under test for different axial positions of the object. The artificial eye admits different artificial corneas, to optimise the axial resolution in the sampling of the MTF of the MIOL under test, and different pupils, to test the dependence of the optical performance of the MIOL on the eye pupil diameter. Results: The performance and sensitivity of the apparatus is tested with different commercial MIOLs…

Models AnatomicOptics and Photonicsbusiness.product_categorygenetic structuresComputer scienceImaging qualityIntraocular lenseslaw.inventionOpticsSampling (signal processing)Through-focus MTFlawOptical transfer functionHumansComputer visionSensitivity (control systems)Multifocal lensesLightingLenses IntraocularOptical setupbusiness.industryMultifocal intraocular lensMultifocal lenseseye diseasesSensory SystemsLens (optics)OphthalmologyImaging qualityFISICA APLICADAsense organsArtificial intelligenceMonochromatic colorbusinessOptometry
researchProduct

Optical performance of two new trifocal intraocular lenses: through-focus modulation transfer function and influence of pupil size

2013

Background To compare the in vitro optical quality of two new trifocal intraocular lenses at different focal points as a function of pupil size. Methods Two intraocular lenses having different design approaches were evaluated: the AT LISA tri 839MP with a trifocal diffractive design, and the FineVision, which combines two distinct apodized bifocal diffractive profiles resulting in three foci. A PMTF optical bench was used to assess the intraocular lenses' performance, and as optical quality metrics, the through-focus modulation transfer function was selected; that is, it was measured at 10 focal points and for four different apertures (2.0, 3.0, 3.75 and 4.5 mm). Results For both lenses, th…

OphthalmologyFocal pointCardinal pointOpticsIntraocular lensesApodizationFocus (geometry)business.industryOptical transfer functionPupil sizeMedicinebusinessPupilClinical & Experimental Ophthalmology
researchProduct

Power profiles in multifocal contact lenses with variable multifocal zone

2016

BACKGROUND The power profile of multifocal contact lenses has been demonstrated to report important information that could be used during the fitting process. The aim of this work is to describe the power profile of a recent set of gas permeable multifocal contact lenses as a function of the pupil radius. METHODS The measured multifocal contact lenses have a centre-distance design, and are available with five distance-vision diameters (XS, S, M, L and XL) and two different additions: Type A (up to +2.00 D) and Type B (up to +2.50 D). The optical device NIMO TR1504 (Lambda-X, Nivelles, Belgium) was used to obtain the power profile measurements. The optical lens power distribution as a functi…

Optical PhenomenaContact LensesApertureVisual AcuityRefraction Ocularlaw.invention03 medical and health sciencesNear vision0302 clinical medicineOpticslawHumansPhysicsbusiness.industryEquipment DesignPresbyopiaRadiusFunction (mathematics)Power (physics)Lens (optics)OphthalmologyVariable (computer science)030221 ophthalmology & optometrybusiness030217 neurology & neurosurgeryOptometryClinical and Experimental Optometry
researchProduct

Oxygen permeability of hydrogel contact lenses with organosilicon moieties

2002

Oxygen transport through two extended wear (day and night) hydrogel contact lenses that contain organosilicon moieties (balafilcon A and lotrafilcon A) was studied in the hydrate (hydrogel) and dry (xerogel) states. The water uptake increased the oxygen permeability [(Dk)app] and transmissibility [Dk/L(av)] coefficients of the dry materials by about 70%. The (Dk)app for the hydrated lenses was determined following the so-called stack procedure. The values obtained were 107 +/- 4 barrer for balafilcon A and 141 +/- 5 barrer for lotrafilcon A, about 5-10 times larger than those previously reported for conventional (without organosilicon moieties) extended wear hydrogels contact lenses. The Dk…

Optics and PhotonicsMaterials scienceBiophysicsAnalytical chemistrychemistry.chemical_elementBioengineeringOxygenHydrogel Polyethylene Glycol DimethacrylatePermeabilityBiomaterialschemistry.chemical_compoundOxygen permeabilityMaterials TestingPolymer chemistryOrganosilicon CompoundsOrganosiliconOxygen transportWaterContact Lenses HydrophilicOxygenchemistryMechanics of MaterialsPermeability (electromagnetism)Self-healing hydrogelsCeramics and CompositesBarrerHydrateBiomaterials
researchProduct