Correlation between optics quality of multifocal intraocular lenses and visual acuity

2009

Purpose To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the “average modulation” of the IOL was assessed. Results The pupil diameter and patient age were similar between the 3 IOL groups (20 …

Optics and Photonicsmedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionColor visionmedicine.medical_treatmentVisual AcuityIntraocular lensPupilOpticsLens Implantation IntraocularOphthalmologymedicineHumansAgedRetrospective StudiesLenses IntraocularPhacoemulsificationColor VisionFourier Analysisbusiness.industryPupilPhacoemulsificationMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologyOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Zilo gaismu bloķējošo lēcu ietekme uz kontrastjutību

2018

Bakalaura darbs ir 21 lappaspusi garš, satur 9. attēlus, 1. tabulu un 39. literatūras atsauces. Darba mērķis ir novērtēt zilo gaismu bloķējošo lēcu ietekmi uz kontrastjutību. Mērījumi tika veikti, izmantojot Pelli-Robsona testu, kurš tika rādīts iPad telefonā. Mērījumā piedalījās 55 dalībnieki. Mērījumi tika veikti ar briļļu lēcām, kurām bija zilo gaismu bloķējošais klājums, kā arī ar lēcām, kurām bija tradicionālais pretatspīdumu klājums. Kontrastjutība bija labāka ar zilo gaismu bloķējošām lēcām nekā ar lēcām, kurām bija tradicionālais pretatspīdumu klājums (p<0.001). Dalībniekiem ar sūdzībām par žilbšanu kontrastjutības uzlabojums ar zilo gaismu bloķējošām lēcām bija lielāks nekā dalībni…

Optometrijaspectacle lenses anti-reflective layer blue light blocking lenses contrast sensitivity glare.
researchProduct

Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients

2016

The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.

Phakic Intraocular Lensesmedicine.medical_specialtyKeratoconusgenetic structuresKeratoconusPhakic intraocular lens03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineLenses Intraocularbusiness.industryfungifood and beveragesRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyQuality of vision030221 ophthalmology & optometryOptometrySurgerysense organsbusiness030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Modulation transfer function: Rigid versus foldable phakic intraocular lenses

2008

Purpose To study in a standard eye model the changes in modulation transfer function (MTF) of a monofocal intraocular lens (IOL) when a phakic IOL (pIOL) is placed in the anterior chamber, compare the MTFs of the rigid Artisan pIOL and foldable Artiflex pIOL, and evaluate the temporal evolution of the MTF of the foldable pIOL after the mechanical stress the pIOL undergoes when injected. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The MTF values of the IOLs were calculated from the cross-line spread function recorded with the Opal Vector System. The measurements were taken using an eye model following the British and EN-ISO standards with 2.0 mm, 3.0 mm, 4.0 mm…

Phakic Intraocular Lensesmedicine.medical_specialtyMaterials scienceOptical PhenomenaAnterior Chambermedicine.medical_treatmentIntraocular lensPhakic intraocular lensModels BiologicalSensory SystemsOptical qualityPupillaw.inventionLens (optics)OphthalmologyLens Implantation IntraocularlawOphthalmologyOptical transfer functionMyopiamedicineHumansSurgeryPhakic iolDioptreJournal of Cataract and Refractive Surgery
researchProduct

The posterior chamber phakic refractive lens (PRL): a review

2012

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…

Phakic Intraocular Lensesmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentVisual performanceOptical qualityReviewAstigmatismRefraction OcularPhakic intraocular lensPhakic refractive lens (PRL)CataractPupilEndophthalmitisLens Implantation IntraocularCataractsOphthalmologyRefractive surgeryMyopiamedicineHumansRefractive surgeryÓpticaPosterior chamber phakic intraocular lensbusiness.industryPatient SelectionEquipment Designmedicine.diseaseeye diseasesOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Posterior Capsule of the LensOptometrysense organsbusinessEye
researchProduct

The fast photon detection system of COMPASS RICH-1

2007

Abstract A fast photon detection system has been built for the upgrade of COMPASS RICH-1, the large size gaseous RICH detector in use at the COMPASS Experiment at the CERN SPS since 2001. The photon detectors of the central region have been replaced by a new system based on multi-anode photomultipliers coupled to individual fused silica lens telescopes and a fast readout electronics system, while in the outer region the existing MWPCs with CsI photocathodes have been equipped with a new readout system, based on the APV chip. RICH-1 has been successfully operated in its upgraded version during the 2006 run. We report on the upgrade design and construction, and on the preliminary characteriza…

PhotomultiplierNuclear and High Energy PhysicsPhotonMulti-anode photomultiplier tubesPhysics::Instrumentation and DetectorsUV lensesCOMPASS; Multi-anode photomultiplier tubes; Photon detection; RICH; UV lenses; Nuclear and High Energy Physics; InstrumentationCOMPASSlaw.inventionFAST-RICH; DEUTERON; READOUT; DESIGNOpticsDESIGNlawMulti-anode photomultiplier tubeCompassCOMPASS experimentRICHInstrumentationNuclear and High Energy PhysicPhysicsLarge Hadron Colliderbusiness.industryDetectorREADOUTDEUTERONLens (optics)UpgradePhoton detectionFAST-RICHUV lenseHigh Energy Physics::Experimentbusiness
researchProduct

High-visibility interference fringes with femtosecond laser radiation.

2009

We propose and experimentally demonstrate an interferometer for femtosecond pulses with spectral bandwidth about 100 nm. The scheme is based on a Michelson interferometer with a dispersion compensating module. A diffractive lens serves the purpose of equalizing the optical-path-length difference for a wide range of frequencies. In this way, it is possible to register high-contrast interference fringes with micrometric resolution over the whole area of a commercial CCD sensor for broadband femtosecond pulses.

PhysicsFemtosecond pulse shapingbusiness.industryLasersAstrophysics::Instrumentation and Methods for AstrophysicsPhysics::OpticsMichelson interferometerEquipment DesignInterference (wave propagation)Atomic and Molecular Physics and Opticslaw.inventionEquipment Failure AnalysisInterferometryRefractometryOpticsInterferometrylawFemtosecondDispersion (optics)OptoelectronicsComputer-Aided DesignbusinessDiffraction gratingCoherence (physics)LensesOptics express
researchProduct

A/V ratio as predicted by full width at half maximum and by blood vessel tracking in presence of ocular aberrations

2011

Aberrations impact A/V ratio calculated from full width at half maximum. We investigated whether aberrations affect A/V ratio calculated by tracking the vessels. Aberrations changed the A/V ratio. We conclude that aberrations impact A/V ratio.

PhysicsFull width at half maximummedicine.anatomical_structureOpticsIntraocular lensesbusiness.industrymedicineTracking (particle physics)businessAdaptive opticsBlood vesselScanning laser ophthalmoscopy
researchProduct

In vitro optical quality differences between multifocal apodized diffractive intraocular lenses.

2013

Purpose To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifocal IOL with 3 main foci (trifocal IOL) were evaluated. The optical quality was quantified using the modulation transfer function (MTF) at 7 focal points and for 3.0 mm and 4.5 mm apertures. The through-focus MTF at 10 focal points of the IOLs was also recorded. Results For the 0.0 D and −2.5 D focal points, the bifocal IOL showed the highest MTF values for pupil sizes as well as …

PhysicsLenses IntraocularFocal pointOptics and Photonicsbusiness.industryApertureProsthesis DesignSensory SystemsOptical qualityOphthalmologyOpticsCardinal pointApodizationIntraocular lensesOptical transfer functionSurgeryVisual FieldsbusinessDioptreVision OcularJournal of cataract and refractive surgery
researchProduct

Modulation transfer function of a toric intraocular lens: evaluation of the changes produced by rotation and tilt.

2011

PURPOSE: To evaluate the changes in optical quality when toric intraocular lenses (IOL) are rotated or tilted and to demonstrate that IOL rotation produces an increasing effect of aberrations. METHODS: Modulation transfer function (MTF) and average modulation were used to analyze the image quality of a toric IOL. The axis of the toric IOL was rotated 5°, 10°, 15°, 20°, 25°, and 30° in successive MTF measurements. The tilt values were 0° to 5°, in increments of 1°, plus a tilt of 15°. Pupil diameters of 3 and 5 mm were used. RESULTS: The MTF decay due to aberrations was more sensitive to rotation than tilt. The main decrement in the average modulation, of approximately 50% in both pupils, o…

PhysicsLenses IntraocularOptics and PhotonicsCorneal Wavefront AberrationRotationbusiness.industrymedicine.medical_treatmentIntraocular lensModels TheoreticalRotationArtificial Lens Implant MigrationOptical qualityExponential functionOphthalmologyTilt (optics)OpticsIntraocular lensesModulationOptical transfer functionmedicineHumansSurgerybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)