In vitro power profiles of multifocal simultaneous vision contact lenses.

2013

Abstract Purpose To evaluate the power profile of multifocal contact lenses (CLs) using a new technology based on quantitative deflectometry. Methods The Nimo TR1504 was used to analyze the power distribution of multifocal CLs. The CLs under study were: Air Optix Aqua Multifocal Low, Medium and High Addition and Focus Progressives. Three lenses of each model were considered. Results All multifocal CLs showed a power profile characterized by a change toward more positive power values when aperture sizes become smaller. The near refractive addition of the lenses under study was +2.61 D, +1.44 D, +1.30 D and +0.30 D for the Focus Progressives, the Air Optix Aqua Multifocal High, Medium Add and…

PhysicsLightbusiness.industryApertureContact LensesOptical powerGeneral MedicinePresbyopiaEquipment Designmedicine.diseaseDistance correctionlaw.inventionPower (physics)Lens (optics)Equipment Failure AnalysisOphthalmologyRefractometryOpticslawmedicineScattering RadiationbusinessFocus (optics)OptometryNominal power (photovoltaic)Contact lensanterior eye : the journal of the British Contact Lens Association
researchProduct

Fast photon detection for COMPASS RICH-1

2007

A fast photon detection system has been built and assembled for the upgrade of COMPASS RICH-1. The system is based on multianode photomultipliers coupled to fused silica lenses to collect the light from a larger surface and to guide it to the photocathode, preserving the position information. The emphasis is on the fast response and high rate capability of the detectors and the associated electronics. The photon detection system is now ready and it will be employed in the 2006 COMPASS data taking. We report about the system design and construction.

PhysicsNuclear and High Energy PhysicsPhotomultiplierbusiness.industryUV lensesEmphasis (telecommunications)DetectorCOMPASSPhotocathodeOpticsUpgradePhoton detectionCompassCOMPASS; RICH; Multianode photomultiplier tubes; UV lenses; Photon detectionMultianode photomultiplier tubesSystems designElectronicsbusinessInstrumentationRICH
researchProduct

Simbol-X Mirror Module Thermal Shields: II-Small Angle X-Ray Scattering Measurements

2009

The formation flight configuration of the Simbol-X mission implies that the X-ray mirror module will be open to Space on both ends. In order to reduce the power required to maintain the thermal stability and, therefore, the high angular resolution of the shell optics, a thin foil thermal shield will cover the mirror module. Different options are presently being studied for the foil material of these shields. We report results of an experimental investigation conducted to verify that the scattering of X-rays, by interaction with the thin foil material of the thermal shield, will not significantly affect the performances of the telescope.

PhysicsPhysics::Instrumentation and DetectorsScatteringbusiness.industryShieldsX-ray bursts X-ray imaging Lenses prisms and mirrorsParticle detectorlaw.inventionTelescopeSettore FIS/05 - Astronomia E AstrofisicaOpticslawShieldAngular resolutionSmall-angle scatteringbusinessX- and gamma-ray telescopes and instrumentation X-ray scattering X-ray sourceFOIL methodAIP Conference Proceedings
researchProduct

Contact lenses: do they really change the opticalperformance?

1996

Abstract In this investigation the quality of two types of optical correction, hydrogel contact lenses and ophthalmic lenses, wascompared by measuring the modulation transferfunction (MTF) of the correcting lens plus visual optics system using an objective method. A merit function was defined in order to allow the direct comparison between the optical performance with the two corrections. A study on 10 subjects was undertaken, measuring the MTF of both corrections by using the double pass method. The results show that the optical quality of contact lenses was higher than that with ophthalmic lenses. The contrast sensitivity function (CSF) and visual acuity (VA) were determined as subjective…

PhysicsVisual acuitygenetic structuresbusiness.industrymedia_common.quotation_subjectOptical correctionObjective methodGeneral Medicineeye diseasesOptical qualitylaw.inventionLens (optics)OphthalmologyOpticsOphthalmic lenseslawMerit functionmedicineContrast (vision)sense organsmedicine.symptombusinessOptometrymedia_commonContact Lens and Anterior Eye
researchProduct

Background Rejection of Charged Particles in the Simbol-X Telescope: Preliminary Study of Protons Scattering

2009

X-ray telescopes equipped with focusing optics in high eccentric orbit, as e.g. Newton-XMM and Chandra, showed a degradation of the detector performance and an important increase of the noise due to soft protons with energy between a few tens of keV and a few MeV, that are focused on the detector through the mirror module. It should be noted that the focusing of the protons by Wolter optics was an unexpected phenomenon. In Simbol-X a magnetic diverter will be implemented to deflect protons, in order to reduce the flux of charged particles impinging upon the focal plane. Obviously the design of the diverter should take into consideration the protons distribution at the exit of the mirror mod…

Physicsbusiness.industryScatteringAstrophysics::High Energy Astrophysical PhenomenaDetectorX-ray opticsCharged particleParticle detectorlaw.inventionTelescopeSettore FIS/05 - Astronomia E AstrofisicaOpticsCardinal pointlawX- and gamma-ray telescopes and instrumentation X-ray beams and x-ray optics Lenses prisms and mirrorsbusinessNoise (radio)AIP Conference Proceedings
researchProduct

Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.

2014

Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…

Point spread functionAdultLaser de excimerPhakic Intraocular LensesVisual acuityVisual acuitymedicine.medical_treatmentKeratomileusis Laser In SituLentes intraoculares; Sensibilidade de contrasteVisual AcuityCeratomileuse assistida por excimer laser in situ/métodosKeratomileusisPhakic intraocular lensMyopia/surgeryPupilKeratomileusis laser in situ/methodsContrast SensitivityYoung Adultlcsh:OphthalmologyLens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansComputer SimulationContrast sensitivityAdaptive opticsSimulationPhysicsLasers excimer/therapeutic useAcuidade visualAberrometryAccommodation OcularGeneral MedicineOphthalmologyTreatment Outcomelcsh:RE1-994Lenses intraocularMiopia/cirurgiaOptometrySpatial frequencymedicine.symptomArquivos brasileiros de oftalmologia
researchProduct

Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.

2013

Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…

Point spread functionAdultMalePhakic Intraocular LensesVisual acuityCorneal Wavefront AberrationAdolescentVisual AcuityAstigmatismPupilContrast SensitivityYoung AdultBioptics (surgery)Lens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansAdaptive opticsSimulationMathematicsAberrometryAstigmatismmedicine.diseaseSensory SystemsOphthalmologyFemaleSpatial frequencymedicine.symptomOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Diffractive corneal inlay for presbyopia

2017

[EN] A conceptually new type of corneal inlays for a customized treatment of presbyopia is presented. The diffractive inlay consists on a small aperture disc having an array of micro-holes distributed inside the open zones of a Fresnel zone plate. In this way, the central hole of the disc lets pass the zero order diffraction and produces an extension of the depth of far focus of the eye, while the diffracted light through the holes in the periphery produce the near focus. Additionally, the micro-holes in the inlay surface fulfill the essential requirement of allowing the flow of nutrients through it to the cells of the corneal stroma. Theoretical and optical-bench experimental results for t…

Point spread functionDiffractionMaterials sciencegenetic structuresCorneal Stromamedicine.medical_treatmentDiffractive lensesVisual AcuityGeneral Physics and AstronomyZone plateProsthesis Design01 natural sciencesGeneral Biochemistry Genetics and Molecular Biologylaw.inventionCornea010309 optics03 medical and health sciences0302 clinical medicineOpticslawcorneaRefractive surgeryCornea0103 physical sciencesmedicineHumansGeneral Materials ScienceRefractive surgerydiffractive lensesintegumentary systemInlaybusiness.industryGeneral EngineeringProstheses and ImplantsPresbyopiaGeneral ChemistryPresbyopiamedicine.diseaseCorneal inlayeye diseasesmedicine.anatomical_structureFISICA APLICADArefractive surgery030221 ophthalmology & optometrysense organsbusinessJournal of Biophotonics
researchProduct

Imaging Performance of a Diffractive Corneal Inlay for Presbyopia in a Model Eye

2019

[EN] In this work we evaluated the imaging properties of the Diffractive Corneal Inlay (DCI), a novel type of corneal implant working by diffraction that we proposed for the treatment of presbyopia. ZEMAX OpticStudio software was employed for the numerical assessment, with simulations performed in a human-based eye model. In the ray tracing analysis, we used the Modulation Transfer Function (MTF), the Area under the MTF (AMTF), and the Point Spread Function (PSF). The theoretical performance of the DCI under different situations was evaluated in comparison with a commercially available pinhole based corneal inlay. Finally, real images were obtained experimentally in vitro in a model eye wit…

Point spread functionGeneral Computer ScienceComputer scienceDiffractive lenses01 natural sciencesoptical design010309 optics03 medical and health sciencesOpticsOptical transfer function0103 physical sciencesmedicine03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edadesGeneral Materials ScienceZemax030304 developmental biologydiffractive lenses0303 health sciencesbusiness.industryGeneral EngineeringPresbyopiaPresbyopiamedicine.diseaseReal imageCorneal inlayPresbyopia Optical designFISICA APLICADARay tracing (graphics)lcsh:Electrical engineering. Electronics. Nuclear engineeringbusinessCorneal inlayslcsh:TK1-9971IEEE Access
researchProduct

Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator

2012

A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulation transfer function is computed. Because there are no moving parts in the experimental setup, this method is fast and versatile to assess MIOLs. Experimental results confirm the potential of the proposed method.

Point spread functionMaterials scienceImage qualityProsthesis DesignOpticsIn-vivoOptical transfer functionDefocus transfer-functionImage qualityDecentrationElectrical and Electronic EngineeringEngineering (miscellaneous)LightingTiltLenses IntraocularSpatial light modulatorbusiness.industryOptical-performanceMultifocal intraocular lensAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryAberrationsTilt (optics)DesignsFISICA APLICADASpatial frequencybusinessFocus (optics)Applied Optics
researchProduct