Search results for "Lenses"

showing 10 items of 294 documents

Effect of the color of the intraocular lens on optical and visual quality

2014

Purpose: To analyze the optical quality of intraocular lenses (IOL) with an orange (PC440Y) and a yellow (SN60AT) filter, and correlate these results with the visual quality of patients with these implants. Setting: Fisabio Oftalmología Médica, Valencia, Spain. Design: Randomized prospective study. Materials and Methods: The IOL optical quality was determined using the modulation transfer function (MTF) and the spectral transmission. The visual quality of 87 eyes with cataract (51 with orange filter and 36 with yellow filter) was determined by best corrected visual acuity (BCVA) and contrast sensitivity function (CSF) under photopic and mesopic conditions. To analyze the results, we use a S…

choroidal thicknessmedicine.medical_specialtyVisual acuityrecurrenceorangegenetic structuresvisual acuityMesopic visionmedicine.medical_treatmentcontrast sensitivity functionIntraocular lensOrange (colour)Cataractsurgerylcsh:OphthalmologyOptical transfer functionOphthalmologymedicinescanning laser polarimetryfilterbusiness.industryChoroidenhanced depth imagingBoth lensesretinal nerve fiber layereye diseasesyellowOphthalmologyglaucomaIntraocular lensesFixed corneal compensationlcsh:RE1-994OptometryExotropiaOriginal Articlesense organsmedicine.symptombusinessPhotopic visionIndian Journal of Ophthalmology
researchProduct

Ortokeratoloģijas ietekme uz ceturtās kārtas aberācijām.

2020

Maģistra darbs ir uzrakstīts angļu valodā uz 36 lapaspusēm. Tas satur 7 attēlus, 7 formulas, 7 tabulas, 3 grafikus un 38 literatūras atsauces. Darba mērķis bija novērtēt radzenes sagitālā augstuma un leņķa, kā arī ceturtās kārtas aberāciju izmaiņas pēc ortokeratoloģijas lēcu lietošanas. Pētījumā tika analizēti radzenes topogrāfijas dati, iegūti no 30 acīm, trīs mēnešus lietojot ortokeratoloģijas lēcas. Rezultāti neuzrādīja būtiskas izmaiņas ceturtās kārtas aberāciju lielumos. Modificējot ortokeratoloģijas lēcu parametrus, ir iespējams saglabāt labu redzes asumu un skotopisko redzi pēc ortokeratoloģijas lēcu lietošanas.

contact lenses with inverse geometryIV order aberrationsvisual acuityBaker’s FormulaorthokeratologyFizika
researchProduct

Optometriskie treniņi pacientiem ar idiopātisku nistagmu.

2020

Maģistra darbs ir uzrakstīts angļu valoda uz 47 lapām. Tas satur 28 attēlus, 2 tabulas un 42 atsauces uz literatūras avotiem. Maģistra darba mērķis ir nodemonstrēt optometrisko rehabilitācijas metožu ietekmi uz infantilu idiopātisko nistagmu (IIN). Desmit pacientiem ar IIN (30 ± 14 g.) tika veiktas sekojošas ārstēšanas metodes: prizmas ar bāzi uz āru, krāsotas kontaktlēcas (zīlītes diametrs 5 mm), audio-biofīdbeka metode. Pirms un pēc ārstēšanas tika novērtēts redzes asums un kontrastredze tālumā un stereoredze tuvumā ar labāko subjektīvo korekciju, nistagma apmlitūda un frekvence. Rezultāti parādīja, ka visas ārstēšanas metodes vienādi ietekmēja redzes asuma, nistagma amplitūdas un frekven…

contact lensesoptometric traininginfantile idiopathic nystagmusaudio-biofeedbackFizikaprism correction
researchProduct

Redzes funkciju izvērtējums pacientiem agrīnā presbiopijas vecumā ar vienas dienas multifokālajām kontaktlēcām

2017

Bakalaura darbs uzrakstīts uz 27 lapaspusēm, satur 18 zīmējumus, 1 tabulu un 20 literatūras avotus. Darba mērķis ir novērtēt redzes asumu un kontrasta jūtību fotopiskos un mezopiskos apstākļos pacientiem, koriģētiem ar brillēm un vienas dienas multifokālajām kontaktlēcām. Mūsu pētījumi parādīja, ka fotopiskos apstākļos pacientiem pēc korekcijas ar multifokālajām kontaktlēcām redzes asums vidēji samazinājās par 0,02 logMAR vienībām. Mezopiskos krēslas apstākļos pacientiem koriģētiem ar multifokālajām kontaktlēcām redzes asuma samazinājums vidēji bija 0.05 logMAR vienības. Atšķirības redzes asumā ir statistiski nozīmīgas. Kontrasta jūtības vidējie lielumi pēc kontaktlēcu uzlikšanas vidēji sam…

contrast sensitivityphotopic conditionpresbyopia correctionmesopic conditionOptometrijamultifocal contact lenses
researchProduct

Ahromatopsijas izpausmju korekcija ar krāsainām kontaktlēcām

2017

MĒRĶIS: Novērtēt filtru kontaktlēcu (KL) pielietojumu ahromatopsijas simptomu korekcijai. METODE: Pētījumā piedalījās 8 dalībnieki (6 sievietes un 2 vīrieši) vecumā no 8 mēnešiem līdz 25 gadiem, periodā no 2012. līdz 2016.gadam. Pēc oftalmoloģiskās pārbaudes un ahromatopsijas noteikšanas, tika veikta speciālās krāsainās KL pielaikošanas procedūra. Pacientu atbildes tika noteiktas ar anketas palīdzību un noteikts apžilbšanas laiks ar un bez piedāvātām KL. SECINĀJUMI: filtru KL samazināja fotofobiju; apžilbšanas laiks kļuvis salīdzināms ar normālā redzes gadījumu; dalībnieki atzinīgi novērtē psiholoģiskos un sociālos ieguvumus ar izrakstītām filtru KL.

filtered contact lensesphotophobiaFizikaglareachromatopsialight
researchProduct

Physicochemical Surface Properties of Various Intraocular Lenses

2001

<i>Purpose:</i> It is of major interest to understand how intraocular lens (IOL) surfaces interact with aqueous humor or tissues after implantation. Important parameters to describe the physicochemical surface properties are the contact angle and critical surface tension. Therefore, we performed measurements of the contact angle and critical surface tension of several commercially available IOLs. <i>Setting:</i> Department of Ophthalmology, Johannes Gutenberg University, Mainz, University Eye Hospital, Tübingen, and Max Planck Institute for Polymer Research, Mainz, Germany. <i>Methods:</i> A total of 17 commercially available standard quality IOL types (6…

genetic structuresBiocompatibilityPolymethyl methacrylatemedicine.medical_treatmentAcrylic ResinsAqueous humorIntraocular lensCellular and Molecular NeuroscienceOpticsCoated Materials BiocompatiblemedicinePolymethyl MethacrylateSurface TensionLenses IntraocularHeparinbusiness.industryChemistryGeneral MedicineBiocompatible materialeye diseasesSensory SystemsSilicone ElastomersOphthalmologyIntraocular lensesSilicone Elastomerssense organsbusinessBiomedical engineeringOphthalmic Research
researchProduct

Schematic eye models to mimic the behavior of the accommodating human eye

2018

A simplified version of the human eye is known as schematic eye model. Since the first attempts in the middle of the 19th century, numerous approaches describing new schematic eye models have been introduced. Some of them are able to describe the accommodation ability of the human eye. Accommodative schematic eyes could be of great interest since they are able to explain the functionality of the human eye and they can be easily used for different research purposes. Some of these include the design and testing of multifocal ophthalmic solutions, evaluation of the effect of optical aberrations on the retinal image quality, and study of the optical performance of the eye at different distances…

genetic structuresComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONSchematic eyeModels Biological01 natural sciencesCornea010309 optics03 medical and health sciencesOcular physiology0302 clinical medicine0103 physical sciencesmedicineHumansbusiness.industryAccommodation OcularSchematicSurgical proceduresÒpticaRefractive ErrorsSensory SystemsRetinal imageeye diseasesOphthalmologymedicine.anatomical_structureIntraocular lenses030221 ophthalmology & optometryOptometrySurgeryHuman eyesense organsbusinessAccommodationUlls
researchProduct

Validation of a spectral light scattering method to differentiate large from small particles in intraocular lenses

2017

A psychophysical approach has been designed to measure straylight from intraocular lenses (IOLs) in vitro. This approach uses a clinical straylight meter (C-Quant) and an observer's eye as optical detector. Based on this, we introduced a method for study of straylight-wavelength dependency for IOLs. This dependency can be used to distinguish between 2 types of scattering particles (small and large) as defined by Mie theory. Validation was performed using a turbidity standard and scattering filters. Several IOLs were analyzed to identify potential scattering sources. Large particles were found to predominate in scattering from the studied lenses. This was confirmed by straylight-angular depe…

genetic structuresForward scatterOptical detectorMie scattering01 natural sciencesLight scatteringArticle010309 optics03 medical and health sciencessymbols.namesake0302 clinical medicineOptics0103 physical sciencesJournal ArticleSmall particlesRayleigh scatteringPhysicsScatteringbusiness.industryequipment and suppliesAtomic and Molecular Physics and Opticseye diseasesIntraocular lenses030221 ophthalmology & optometrysymbolssense organsbusinessBiotechnologyBiomedical Optics Express
researchProduct

Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses. results of a multicenter questionnaire.

2001

Abstract Purpose To compare the incidence and severity of photic phenomena after the implantation of the Array® (Allergan) refractive multifocal intraocular lens (MIOL) and a monofocal IOL. Setting Multicenter study at Kiel, Mainz, Karlsruhe, and Bremerhaven, Germany. Methods The study comprised 231 randomly selected patients from 4 study centers. The patients had had uneventful phacoemulsification with implantation of a refractive MIOL (n = 138) or a monofocal IOL (n = 93). By questionnaire, patients were asked whether they experienced light sensations postoperatively (light streaks, halos, flare, flashes, or glare) that had not been noticed preoperatively. Additional questions evaluated w…

genetic structuresLightmedicine.medical_treatmentEye diseaseVision DisordersIntraocular lensGlareVision disorderLens Implantation IntraocularSurveys and QuestionnairesmedicineHumansLenses IntraocularPhacoemulsificationbusiness.industryIncidenceGlare (vision)PhacoemulsificationMultifocal intraocular lensCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyMulticenter studyOptometrySurgerysense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Modulation transfer function in refractive-diffractive multifocal intraocular lenses in vitro

2007

Purpose: The optical quality of two types of multifocal, hybrid refractive-diffractive, intraocular lenses (IOL) is analyzed in vitro. Following the EN-ISO international standard, the IOLs’ modulation transfer functions (MTF) are determined for both distance and near vision. The behaviour of these curves when the pupil size varies is studied. Methods: The IOLs analyzed were: AcrySoft ResTor SN60D3 (Alcon) and Tecnis ZM900 (AMO). The MTF was calculated from the cross line-spread function recorded with the OPAL Vector System (Image Science Ltd. Oxford) by using fast Fourier transform techniques. The artificial eye model used simulates in vivo conditions of the anterior chamber including an ar…

genetic structuresbusiness.industryImage qualityStrehl ratioMultifocal intraocular lenseye diseasesPupilOptical qualityOphthalmologyOpticsIntraocular lensesOptical transfer functionMedicinesense organsImaging sciencebusinessActa Ophthalmologica Scandinavica
researchProduct