Search results for "Lenses"
showing 10 items of 294 documents
Effect of 3rd-order aberrations on human vision
2007
To investigate the effect of 3rd-order aberrations on human vision.Grupo de Ciencias de la Visión, University of Murcia, Murcia, Spain.The 3rd-order aberrations coma and trefoil were induced with purpose-designed soft contact lenses, 3 inducing coma (low [0.05 microm], medium [0.13 microm], high [1.03 microm]) and 3 inducing trefoil (low [0.07 microm], medium [0.17 microm], high [0.96 microm]). Monocular high-contrast (HCVA) and low-contrast (LCVA) visual acuities and contrast sensitivity were measured in 11 subjects wearing contact lenses with a 5.0 mm artificial pupil.The reduction in HCVA and LCVA was statistically significant only for the highest coma and trefoil values (P.0001). For co…
Long-term follow-up of a multifocal apodized diffractive intraocular lens after cataract surgery.
2007
Purpose To report the long-term performance of the AcrySof ReSTOR SA60D3 intraocular lens (IOL) after cataract surgery. Setting University Hospital Maastricht, Maastricht, The Netherlands. Methods This prospective clinical trial comprised 44 eyes (22 consecutive patients) having cataract surgery with implantation of the ReSTOR IOL. Monocular and binocular uncorrected distance visual acuity, best corrected distance visual acuity, uncorrected near visual acuity, best distance-corrected near visual acuity, spectacle dependence, undesired visual symptoms, patient satisfaction, and incidence of posterior capsule opacification were analyzed 6 months and 3 years postoperatively. Results The mean u…
Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens
2005
Purpose To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindi…
Tear film stability over a myopia control contact lens compared to a monofocal design
2021
Background: To compare the short-term effect of two contact lenses on pre-lens tear film stability and comfort: dual-focus contact lens (MiSight) and a monofocal contact lens (Proclear 1-day).Methods: This randomised, double-masked, crossover study was performed in twenty-eight healthy, myopic volunteers aged between 18 and 32 years (23.5 +/- 4.1 years). Only one randomly chosen eye was assessed. Distance vision and refraction were evaluated at baseline. Each contact lens type (monofocal and dual-focus) was randomly fitted, always in both eyes. A visual analogue scale between 0 and 10 was used to assess general comfort, physical comfort, and visual comfort. Tear Film Surface Quality (TFSQ) …
Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator
2013
To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…
Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens
2009
Purpose To determine whether the difference in optic quality between 2 types of phakic intraocular lenses (pIOLs) affects visual quality. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Before implantation of a pIOL for myopia, all eyes had an examination including corrected (CDVA) and uncorrected (UDVA) distance visual acuity testing, corneal endothelial cell count (ECC), and intraocular pressure (IOP) measurement. The postoperative outcomes, determined at least 1 year after surgery, were CDVA; UDVA; contrast sensitivity function under photopic, mesopic, and mesopic with glare conditions; ECC; IOP; keratometry (Scheimpflug photography); and total ocular aberratio…
Fixed Mydriatic Pupil Associated with an Intraocular Pressure Rise as a Complication of the Implant of a Phakic Refractive Lens (PRL)
2013
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in o…
Differences in Corneal Anatomy in a Pair of Monozygotic Twins Due to Continuous Contact Lens Wear
2003
Purpose To study the differences in the corneal anatomy in a pair of 31-year-old monozygotic female twins, one of whom has been a contact lens wearer for the past 15 years and the other is a nonwearer. Methods We analyzed the corneal thickness and the corneal endothelial cell density of the monozygotic twins and of two age-matched control groups, one made up of non-contact lens wearers (35 eyes of 35 patients; mean age, 29.32 +/- 2.83 years) and the other made up of soft contact lens wearers (30 eyes of 30 patients; mean age, 33.08 +/- 3.72 years; mean duration of contact lens use, 10.62 +/- 4.32 years). Five corneal thickness measurements were carried out with the Orbscan Topography System…
OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers
2011
PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…
Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser
2011
PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens gro…