Search results for "Libration"
showing 10 items of 901 documents
Uncertainty Management in the measurements performed by means of virtual instruments
2008
The uncertainty management is the discipline of optimising the cost of a measurement versus the uncertainty target. In particular, the paper deals with the measurements performed by using a generic virtual instrument. The task is achieved by using the PUMA (procedure for uncertainty management) method that is an iterative technique originally conceived for geometrical and mechanical measurements. The approach is completely based on the "guide to the expression of uncertainty in measurement" rules, but provides a more engineering methodology, since it allows to optimize the cost of the measurements versus the uncertainty target, avoiding the use of inadequate or, on the contrary, too expensi…
PCM Thermal Energy Storage in Buildings: Experimental Study and Applications
2015
Abstract The study aims at analyzing the performance of Phase Change Materials (PCMs) in residential housing for different climates. This paper presents the results of an experiment performed in the Concordia University Solar Simulator and Environmental Chamber research facility (SSEC, Montreal, Canada). PCM boards were embedded on the back wall of a test hut placedin the climatic chamber. Several experiments were performed to explore the potential for verification of the proposed analysis and to produce enough data to perform model calibrations. Results show a strong increase in the apparent thermal inertia of the room allowing for a reduction in daily temperature fluctuations in the test …
Comparison of different uncertainty techniques in urban stormwater quantity and quality modelling
2011
Abstract Urban drainage models are important tools used by both practitioners and scientists in the field of stormwater management. These models are often conceptual and usually require calibration using local datasets. The quantification of the uncertainty associated with the models is a must, although it is rarely practiced. The International Working Group on Data and Models, which works under the IWA/IAHR Joint Committee on Urban Drainage, has been working on the development of a framework for defining and assessing uncertainties in the field of urban drainage modelling. A part of that work is the assessment and comparison of different techniques generally used in the uncertainty assessm…
Hybrid moving bed biofilm reactors: an effective solution for upgrading a large wastewater treatment plant
2009
Over the last few years there has been a growing attention regarding the receiving water body quality state. As a matter of a fact, the Directive 91/271 of the European Union (EU) replaced the “emission standard” concept that fixes discharge limits depending on polluting emission characteristics, with the “stream standard” concept that fixes discharge limits for each polluting substance depending on self-depurative characteristics of the RWB. In this context, several WWTPs need to be upgraded in order to meet stricter effluent limits. The need of WWTP upgrading was also emphasized by the growing urbanization that have led, in most cases, to get overloaded WWTP due to an overcoming of the ma…
comparing two start-up strategies for MBRs: experimental study and mathematical modelling
2012
Abstract The performance of a membrane bioreactor (MBR), and mechanisms of fouling formation, may differ due to the start-up. Therefore, the start-up can constitute an aspect that critically influences MBR performance during its lifespan. Indeed, the start-up can influence the mechanisms of membrane fouling, which is of paramount importance in an MBR. In order to gain insights on the effects of the start-up, both experimental and mathematical modelling studies were carried out on an MBR pilot plant. The MBR pilot plant constituted of a hollow fibre membrane module, in a submerged configuration, was fed by real wastewater. Two experimental periods were carried out, lasting 65 days each, char…
Global sensitivity analysis in wastewater applications: A comprehensive comparison of different methods
2013
Three global sensitivity analysis (GSA) methods are applied and compared to assess the most relevant processes occurring in wastewater treatment systems. In particular, the Standardised Regression Coefficients, Morris Screening and Extended-FAST methods are applied to a complex integrated membrane bioreactor (MBR) model considering 21 model outputs and 79 model factors. The three methods are applied with numerical settings as suggested in literature. The main objective considered is to classify important factors (factors prioritisation) as well as non-influential factors (factors fixing). The performance is assessed by comparing the most reliable method (Extended-FAST), by means of proposed…
Parameter subset selection for the dynamic calibration of activated sludge models (ASMs): experience versus systems analysis.
2007
In this work we address the issue of parameter subset selection within the scope of activated sludge model calibration. To this end, we evaluate two approaches: (i) systems analysis and (ii) experience-based approach. The evaluation has been carried out using a dynamic model (ASM2d) calibrated to describe nitrogen and phosphorus removal in the Haaren WWTP (The Netherlands). The parameter significance ranking shows that the temperature correction coefficients are among the most influential parameters on the model output. This outcome confronts the previous identifiability studies and the experience based approaches which excluded them from their analysis. Systems analysis reveals that parame…
Calibration and simulation of two large wastewater treatment plants operated for nutrient removal
2004
Control and optimisation of plant processes has become a priority for WWTP managers. The calibration and verification of a mathematical model provides an important tool for the investigation of advanced control strategies that may assist in the design or optimization of WWTPs. This paper describes the calibration of the ASM2d model for two full scale biological nitrogen and phosphorus removal plants in order to characterize the biological process and to upgrade the plants' performance. Results from simulation showed a good correspondence with experimental data demonstrating that the model and the calibrated parameters were able to predict the behaviour of both WWTPs. Once the calibration an…
Experimental validation of a direct pre-design formula for TLCD
2014
The passive control of vibrations has received in recent years a great deal of attention from researchers. Several types of devices have been proposed in order to reduce the dynamic responses of different kinds of structural systems. Among them, the Tuned Liquid Column Damper (TLCD) has proved to be very effective in reducing vibration of structures. However, since the equations governing the TLCD controlled systems response is nonlinear, the calibration of TLCD parameters is time consuming and not convenient to perform in a pre-design phase. In this context, it has recently been introduced by the authors a formula that allows to choose the optimal parameters of TLCD in a direct and fast wa…
Global sensitivity analysis of a filtration model for submerged anaerobic membrane bioreactors (AnMBR)
2014
The results of a global sensitivity analysis of a filtration model for submerged anaerobic MBRs (AnMBRs) are assessed in this paper. This study aimed to (1) identify the less- (or non-) influential factors of the model in order to facilitate model calibration and (2) validate the modelling approach (i.e. to determine the need for each of the proposed factors to be included in the model). The sensitivity analysis was conducted using a revised version of the Morris screening method. The dynamic simulations were conducted using long-term data obtained from an AnMBR plant fitted with industrial-scale hollow-fibre membranes. Of the 14 factors in the model, six were identified as influential, i.e…