Search results for "Lighting"
showing 10 items of 140 documents
Experimental validation of the BAC factor method for lighting systems
2017
In the last few years, many buildings have been equipped with Building Automation and Control (BAC) systems. BAC systems can be used to achieve a significant reduction of the electrical consumption and to have all the well acknowledged benefits from the daylight (e.g. occupant comfort, health, well-being and productivity). For this reason, Standard EN 15232 "Energy performance of buildings — Impact of Building Automation, Controls and Building Management" puts into evidence the importance of the presence of BAC and Technical Building Management (TBM) systems, suggests a classification of these systems, explains their main functionalities and presents a simplified method to estimate their im…
A set of indices to assess the real performance of daylight-linked control systems
2017
Abstract The installation of Building Automation Control Systems (BACs) in general is an effective action to achieve relevant energy savings. Commercial BACs, installed in residential or small offices, often include functions of lighting control, acting as Daylight-Linked Control Systems (DLCSs). Nevertheless, because system performance is strictly dependent on different parameters, BAC’s hardware and software configuration and as well as an inaccurate commissioning do not always allow a perfect execution of the desired tasks; therefore, the system could not work as expected. Moreover, it is well known that energy saving potential is specifically related to the variability of the light envi…
A Multifunctional Public Lighting Infrastructure, Design and Experimental Test
2017
Nowadays, the installation of efficient lighting sources and Information and Communications Technologies can provide economic benefits, energy efficiency, and visual comfort requirements. More advantages can be derived if the public lighting infrastructure integrates a smart grid. This study presents an experimental multifunctional infrastructure for public lighting, installed in Palermo. The system is able to provide smart lighting functions (hotspot Wi-Fi, video-surveillances, car and pedestrian access control, car parking monitoring and support for environmental monitoring). A remote control and monitoring platform called “Centro Servizi” processes the information coming from…
An Overview on Solar Shading Systems for Buildings
2014
Abstract In recent years, different types of solar shading devices have been proposed, depending on building orientation, location, window characteristics, etc. They can contribute to improve or worsen building thermal and lighting performances both from an energy and comfort point of view. The present paper reports a critical analysis of some studies that investigate shading devices’ effects on building thermal and/or lighting performances. This article points out the difficulty in comparing the different results given the lack of uniformity between the studies, since they analysed buildings with different characteristics, locations and using various indices. Therefore a protocol to carry …
Glass Surfaces for Benefits of Daylight in Social Housing
2017
Internal environment and appropriate natural lighting of the building interior largely affects the health status and course of treatment of patients with psychiatric diagnoses such as depression, Alzheimer and disorder of functions. In particolar, this paper aims to show how smart glass surfaces, allowing the entry of natural lighting, can better support therapeutic process. It is important to elaborate knowledge for optimized lighting conditions in different healthy populations as well as in patients suffering from visual impairments and circadian rhythm disorders. To contribute to the development of new technologies about smart glass surfaces related to various aspects of light conditions…
Sizing analysis of interior lighting using tubular daylighting devices
2017
Abstract Daylight access and indoor thermal comfort are key issues for high design level of sustainable buildings. In fact, daylight provides energy savings and visual comfort condition that can foster higher productivity and performance. This paper proposes a case study of sizing of daylight devices for zenith light. It enables the decision-making process of the designer to reach high levels of daylight factor. The proposed method is shown with an example of application. For the case study, a room in south of Italy, 24 different solar tunnels configurations and 12 cases with different number of skylights have been evaluated.
An experimental study on relationship between LED lamp characteristics and non image-forming
2017
The general aim of the experimental study, presented in this paper, was that to investigate the relationship between the characteristics of five different types of LED (Light Emitting Diode) lamps, which are nowadays those allowing the highest energy consumption reduction, and the humans non image-forming (NIF) reactions.
Lighting control systems: Factors affecting energy savings' evaluation
2015
Abstract The use of automated lighting control systems allows to reduce lighting costs and to achieve significant energy savings. The energy performances of controls are affected by many factors, the impact of which is very difficult to account for during the design process. The goal of this paper is to describe the factors that influence the control systems’ energy performances, to analyze how the currently available calculation tools take them into account and finally to propose a simple method to adjust results obtained from the simulation software.
Energy Savings through Integration of the Illumination Natural and Artificial, Using a System of Automatic Dimming: Case Study
2013
The reduction of electrical energy consumption in buildings is a subject of great interest in the international scientific community. In buildings with a lot of available natural light, designed with large glazed surfaces, the artificial lighting system is often oversized and cannot be divided into segments to meet lighting demands during daylight hours.This article presents an experimental study, conducted in a university lecture hall that has a glazed surface covering the whole wall at one end, which provides a level of internal illumination that is only sufficient for the area next to the window itself, even when the outside lighting conditions are very bright. It is therefore necessary …
Effect of Motion Artifact on Digital Camera Based Heart Rate Measurement
2017
International audience; Depression is one of the most prevalent mental disorders, burdening many people world-wide. A system with the potential of serving as a decision support system is proposed, based on novel features extracted from facial expression geometry and speech, by interpreting non-verbal manifestations of depression. The proposed system has been tested both in gender independent and gender based modes, and with different fusion methods. The algorithms were evaluated for several combinations of parameters and classification schemes, on the dataset provided by the Audio/Visual Emotion Challenge of 2013 and 2014. The proposed framework achieved a precision of 94.8% for detecting p…