Search results for "Limit of Detection"
showing 10 items of 146 documents
Detection of the synthetic drug 4-fluoroamphetamine (4-FA) in serum and urine.
2010
Abstract 4-Fluoroamphetamine (4-FA) was detected in the blood and urine of two individuals suspected for driving under the influence (DUI). The test for amphetamines in urine subjected to immunoassay screening using the CEDIA DAU assay proved positive. Further investigations revealed a 4-FA cross-reactivity of about 6% in the CEDIA amphetamine assay. 4-FA was qualitatively detected in a general unknown screening for drugs using GC/MS in full scan mode. No other drugs or fluorinated phenethylamines were detected. A validated GC/MS method was established in SIM mode for serum analysis of 4-FA with a limit of detection (LOD) of 1 ng/mL and a lower limit of quantification (LLOQ) of 5 ng/mL. Int…
Application of a low transition temperature mixture for the dispersive liquid–liquid microextraction of illicit drugs from urine samples
2021
© 2021 by the authors.
Combined heterologies for monoclonal antibody-based immunoanalysis of fluxapyroxad
2018
Nowadays, instrumental methodologies and rapid bioanalytical techniques complement each other for the analysis of toxic chemical compounds. Fluxapyroxad was commercialized a few years ago as a fungicide and today it is being used worldwide to control a variety of pests. In the present study, the development of monoclonal antibody-based immunochemical methods for the analysis of this chemical in food samples was evaluated for the first time. Novel haptens were synthesized and protein bioconjugates were prepared. High-affinity and specific monoclonal antibodies to fluxapyroxad were generated from two haptens with alternative linker tethering sites. Haptens with linker site heterology and a st…
A sustainable on-line CapLC method for quantifying antifouling agents like irgarol-1051 and diuron in water samples: Estimation of the carbon footpri…
2016
In this work, in-tube solid phase microextraction (in-tube SPME) coupled to capillary LC (CapLC) with diode array detection has been reported, for on-line extraction and enrichment of booster biocides (irgarol-1051 and diuron) included in Water Frame Directive 2013/39/UE (WFD). The analytical performance has been successfully demonstrated. Furthermore, in the present work, the environmental friendliness of the procedure has been quantified by means of the implementation of the carbon footprint calculation of the analytical procedure and the comparison with other methodologies previously reported. Under the optimum conditions, the method presents good linearity over the range assayed, 0.05-1…
A miniaturized method for estimating di(2-ethylhexyl) phthalate in bivalves as bioindicators.
2012
This work has developed a miniaturized method based on matrix solid phase dispersion (MSPD), using C18 as dispersant and acetonitrile-water as eluting solvent, for the analysis of di(2-ethylhexyl) phthalate (DEHP) in biota samples by capillary liquid chromatography coupled to in-tube solid phase microextraction and diode array detection. Recovery studies showed that the combination of C18-Florisil® was optimal using low amount of samples (0.1 g) and with low volumes of acetonitrile-water (2.6 mL 1:3.25, v/v). The sample is processed in less than 30 min, no evaporation step is required. The proposed method was applied to the analysis of DEHP in mussels and of the coastal waters in which they…
Selective chromo-fluorogenic detection of DFP (a Sarin and Soman mimic) and DCNP (a Tabun mimic) with a unique probe based on a boron dipyrromethene …
2014
[EN] A novel colorimetric probe (P4) for the selective differential detection of DFP (a Sarin and Soman mimic) and DCNP (a Tabun mimic) was prepared. Probe P4 contains three reactive sites; i.e. (i) a nucleophilic phenol group able to undergo phosphorylation with nerve gases, (ii) a carbonyl group as a reactive site for cyanide; and (iii) a triisopropylsilyl (TIPS) protecting group that is known to react with fluoride. The reaction of P4 with DCNP in acetonitrile resulted in both the phosphorylation of the phenoxy group and the release of cyanide, which was able to react with the carbonyl group of P4 to produce a colour modulation from pink to orange. In contrast, phosphorylation of P4 with…
Ion-pair in-tube solid-phase microextraction and capillary liquid chromatography using a titania-based column: application to the specific lauralkoni…
2012
Abstract A quick, miniaturized and on-line method has been developed for the determination in water of the predominant homologue of benzalkonium chloride, dodecyl dimethyl benzyl ammonium chloride or lauralkonium chloride (C 12 -BAK). The method is based on the formation of an ion-pair in both in-tube solid-phase microextraction (IT-SPME) and capillary liquid chromatography. The IT-SPME optimization required the study of the length and nature of the stationary phase of capillary and the processed sample volume. Because to the surfactant character of the analyte both, the extracting and replacing solvents, have played a decisive role in the IT-SPME optimized procedure. Conditioning the capil…
Quantitative Analysis of Terpenic Compounds in Microsamples of Resins by Capillary Liquid Chromatography
2019
A method has been developed for the separation and quantification of terpenic compounds typically used as markers in the chemical characterization of resins based on capillary liquid chromatography coupled to UV detection. The sample treatment, separation and detection conditions have been optimized in order to analyze compounds of different polarities and volatilities in a single chromatographic run. The monoterpene limonene and the triterpenes lupeol, lupenone, &beta
Antibody generation and immunoassay development in diverse formats for pyrimethanil specific and sensitive analysis
2012
Immunochemical techniques are complementary tools to modern analytical requirements. These methods rely on the production of immunoreagents with adequate binding properties. In the present study, a rationally designed and functionalized derivative of pyrimethanil-a modern anilinopyrimidine fungicide-was synthesized in order to generate for the first time high-affinity and selective antibodies to this xenobiotic. A single coupling procedure-based on hapten activation using N,N′-disuccinimidyl carbonate and purification of the active ester-was followed to prepare both immunizing and assay conjugates. Polyclonal antibodies were produced and characterized by enzyme-linked immunosorbent assay (E…
An in-tube SPME device for the selective determination of chlorophyll a in aquatic systems.
2010
We report a new device for the estimation of the content of chlorophyll a pigment in water samples as an indicator of water quality. The extraction of the pigment from water was also optimized. 10 mL of water was filtered through a nylon filter (45m pore size and 13 mm of diameter), after the chlorophylls were dissolved by immersing the filter in 1 mL of a low non-hazardous solvent as ethanol. An in-valve in-tube SPME device coupled to capillary liquid chromatography with diode array detection was designed. A capillary column of 70 cm in length (0.32 mm i.d. coated with 5% diphenyl–95% polydimethylsiloxane, 3m coating thickness) was used as the loop of the injection valve for preconcentrati…