Validity of Hip-worn Inertial Measurement Unit Compared to Jump Mat for Jump Height Measurement in Adolescents

2018

Jump tests assess lower body power production capacity, and can be used to evaluate athletic ability and development during growth. Wearable inertial measurement units (IMU) seem to offer a feasible alternative to laboratory-based equipment for jump height assessments. Concurrent validity of these devices for jump height assessments has only been established in adults. Therefore, the purpose of this study was to evaluate the concurrent validity of IMU-based jump height estimate compared to contact mat-based jump height estimate in adolescents. Ninety-five adolescents (10-13 years-of-age; girls N = 41, height = 154 (SD 9) cm, weight = 44 (11) kg; boys N = 54, height = 156 (10) cm, weight = 4…

MaleAdolescentConcurrent validity030209 endocrinology & metabolismPhysical Therapy Sports Therapy and RehabilitationAthletic PerformancekuntotestitAccelerometerwearableWearable Electronic Devices03 medical and health sciencesVertical jump0302 clinical medicineLower bodyInertial measurement unitStatisticsHumansOrthopedics and Sports MedicineChildta315MathematicsLimits of agreementReproducibility of Resultsmethodology030229 sport sciencesFlight timemittausmenetelmätaccelerometerExercise TestJumpFemalehyppääminenconcurrentScandinavian Journal of Medicine and Science in Sports
researchProduct

Evaluation of left ventricular mass on cadmium-zinc-telluride imaging: Validation against cardiac magnetic resonance

2017

Background. Single-photon emission computed tomography has shown relevant limitations in the quantification of left ventricular (LV) mass. We sought to compare the estimates of LV mass on Cadmium-Zinc-Telluride (CZT) myocardial perfusion imaging (MPI) as compared to cardiac magnetic resonance (CMR). Methods and results. Twenty-five patients underwent MPI on a CZT camera and CMR on a 1.5 T scanner within 12 ± 3 weeks. LV mass was quantified on CZT images using two softwares: 4D-MSPECT (4DM) and Emory Cardiac Toolbox (ECTb). LV mass by CMR was quantified using MASS software (Medis, Leiden, The Netherlands). LV mass values obtained with 4DM and ECTb were highly reproducible [intraclass correla…

MaleIntraclass correlationHeart Ventricles030204 cardiovascular system & hematologyleft ventricular masscardiac magnetic resonance030218 nuclear medicine & medical imagingHeart NeoplasmsLeft ventricular mass03 medical and health sciencesMyocardial perfusion imagingchemistry.chemical_compound0302 clinical medicinePredictive Value of TestsNuclear Medicine and ImagingHumansMedicineRadiology Nuclear Medicine and imagingAgedRetrospective StudiesAged 80 and overTomography Emission-Computed Single-Photonmedicine.diagnostic_testbusiness.industryLimits of agreementMyocardial Perfusion ImagingReproducibility of ResultsCadmium-Zinc-Telluride Æ cardiac magnetic resonance Æ SPECT Æ left ventricular massMiddle AgedMagnetic Resonance ImagingCadmium zinc tellurideZincchemistryCadmium-Zinc-Telluride; cardiac magnetic resonance; left ventricular mass; SPECT; Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular MedicineSPECTCadmium-Zinc-TellurideFemaleTelluriumRadiologyCardiology and Cardiovascular MedicineNuclear medicinebusinessCardiac magnetic resonanceEmission computed tomographyCadmiumJournal of Nuclear Cardiology
researchProduct

Validation of two portable bioelectrical impedance analyses for the assessment of body composition in school age children

2017

Background Bioelectrical impedance analysis (BIA) is a convenient and child-friendly method for longitudinal analysis of changes in body composition. However, most validation studies of BIA have been performed on adult Caucasians. The present cross-sectional study investigated the validity of two portable BIA devices, the Inbody 230 (BIA8MF) and the Tanita BC-418 (BIA8SF), in healthy Taiwanese children. Methods Children aged 7–12 years (72 boys and 78 girls) were recruited. Body composition was measured by the BIA8SF and the BIA8MF. Dual X-ray absorptiometry (DXA) was used as the reference method. Results There were strong linear correlations in body composition measurements between the BIA…

MalePediatricsResearch ValidityCross-sectional studylcsh:MedicinePediatricsDiagnostic RadiologyFamilies0302 clinical medicineMathematical and Statistical TechniquesAbsorptiometry PhotonMedicine and Health SciencesElectric ImpedanceMedicine030212 general & internal medicinelcsh:ScienceChildChildrenMusculoskeletal SystemMultidisciplinarySchool age childRadiology and ImagingLimits of agreementResearch AssessmentArmsConcordance correlation coefficientArticle-Level MetricsAdipose TissuePhysical SciencesBody CompositionRegression AnalysisFemaleAnatomyBioelectrical impedance analysisStatistics (Mathematics)Research Articlemedicine.medical_specialtyImaging Techniques030209 endocrinology & metabolismLinear Regression AnalysisResearch and Analysis MethodsFat mass03 medical and health sciencesDiagnostic MedicineLinear regressionHumansAbsorptiometryStatistical MethodsAltmetricsbusiness.industrylcsh:RLimbs (Anatomy)Biology and Life SciencesReproducibility of ResultsBiological TissueCross-Sectional StudiesAge GroupsPeople and PlacesLean body masslcsh:QPopulation GroupingsbusinessNuclear medicineMathematicsPLoS ONE
researchProduct

Film and digital periapical radiographs for the measurement of apical root shortening

2012

Objectives: The aim of this study was to compare the accuracy and agreement of scanned film and digital periapical radiographs for the measurement of apical root shortening. Study design: Twenty-four film and digital [phosphor plate sensor (PPS)] periapical radiographs were taken using the long-cone paralleling technique for six extracted teeth before and after 1mm of apical root trimming. All teeth were mounted using a typodont and the radiographs were recorded using a film holder and polysiloxane occlusal index for each tooth to ensure standardization during the different radiographic exposures. The film radiographs were scanned and the tooth length measurements for the scanned film and d…

MeasurementTypodontRoot shorteningMaterials scienceDentistry(all)business.industryResearchPeriapical radiographyRadiographyLimits of agreementParalleling techniqueDentistryOdontología:CIENCIAS MÉDICAS [UNESCO]DigitalCiencias de la saludPeriapical radiographs/dk/atira/pure/subjectarea/asjc/3500Tooth lengthClinical and Experimental DentistryUNESCO::CIENCIAS MÉDICASbusinessGeneral DentistryFilmJournal of Clinical and Experimental Dentistry
researchProduct

Impact of Aortic Diameter Measurements at Three Anatomical Landmarks on Left Ventricular Output Calculation in Neonates

2021

OBJECTIVES To assess reproducibility and accuracy of left ventricular output (LVO) quantifications in neonates, when left ventricular outflow tract diameter (LVOTD) was measured at the hinges of the aortic valve (AV), at the aortic sinus (AS), and at the sinotubular junction (STJ). METHODS This was an observational study. In the first cohort of very preterm neonates, we assessed intraobserver and interobserver repeatability of LVOTD measured at the AV, AS, and STJ and of the corresponding LVO. In the second cohort of older neonates, we compared paired LVO measurements by echo and magnetic resonance imaging (MRI). RESULTS In the first cohort of 48 neonates, mean (standard deviation) weight a…

Observer VariationAortic valveReproducibilityRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryHeart VentriclesLimits of agreementInfant NewbornReproducibility of ResultsMagnetic resonance imagingRepeatabilitymedicine.anatomical_structureEchocardiographyAortic ValveAortic sinusHumansMedicineVentricular outflow tractRadiology Nuclear Medicine and imagingAortic diameterbusinessNuclear medicineJournal of Ultrasound in Medicine
researchProduct

B-mode versus A-mode ultrasonographic measurements of mucosal thickness in vivo

2002

Abstract Objective: The objective of this study was to compare the measurement accuracy of A-mode and B-mode ultrasonographic assessments of palatal masticatory mucosal thickness in vivo. Study Design: Thickness of palatal masticatory mucosa in the molar region of 50 volunteers was measured once with a B-mode ultrasound device (10 MHz) combined with a standoff for intraoral applications. At identical reading points thickness was also assessed with an A-mode device (5 replicates) and by needle probing for determination of true thickness. Results: On average true thickness ranged between 2.9 and 3.3 mm (95% confidence intervals; median, 3.1 mm). B-mode ultrasonography overestimated truth by 0…

Palate HardMolarmedicine.medical_specialtyAccuracy and precisionUltrasound devicebusiness.industryLimits of agreementMouth MucosaReproducibility of ResultsSignal Processing Computer-AssistedConfidence intervalSurgeryMasticatory forceOtorhinolaryngologyReference ValuesIn vivoHumansMedicineSurgeryOral SurgeryUltrasonographybusinessNuclear medicineGeneral DentistryUltrasonographyOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology
researchProduct

Relationship Between the Critical Power Test and a 20-min Functional Threshold Power Test in Cycling.

2021

To investigate the agreement between critical power (CP) and functional threshold power (FTP), 17 trained cyclists and triathletes (mean ± SD: age 31 ± 9 years, body mass 80 ± 10 kg, maximal aerobic power 350 ± 56 W, peak oxygen consumption 51 ± 10 mL⋅min–1⋅kg–1) performed a maximal incremental ramp test, a single-visit CP test and a 20-min time trial (TT) test in randomized order on three different days. CP was determined using a time-trial (TT) protocol of three durations (12, 7, and 3 min) interspersed by 30 min passive rest. FTP was calculated as 95% of 20-min mean power achieved during the TT. Differences between means were examined using magnitude-based inferences and a paired-samples…

lcsh:QP1-981PhysiologyLimits of agreementcycling performancepower-duration relationshiplcsh:Physiologyfatigue thresholdTime trialAnimal sciencePower testPhysiology (medical)Critical powerexercise tolerancefunctional threshold powerCyclingMathematicsOriginal ResearchFrontiers in physiology
researchProduct

Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer

2020

PURPOSE To evaluate the agreement between different parameters obtained with 2 swept-source optical coherence tomography (SS-OCT)-based biometers and 1 Scheimpflug camera with partial coherence interferometry (PCI). SETTING Single center, Oftalvist, Alicante, Spain. DESIGN Prospective case series. METHODS Biometry was performed in 49 eyes using 3 optical biometers: ANTERION SS-OCT, IOLMaster 700 SS-OCT, and Pentacam AXL PCI. Keratometry (K), J0 and J45 vectors, anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white (WTW), lens thickness (LT), and axial length (AL) were measured with each device. Bland-Altman analysis was applied. RESULTS This study comprises 49 eyes o…

medicine.medical_specialtyBiometryAnterior ChamberScheimpflug principlelaw.inventionCornea03 medical and health sciences0302 clinical medicineOptical coherence tomographyLens thicknesslawOphthalmologymedicineHumansProspective StudiesMathematicsKeratometermedicine.diagnostic_testLimits of agreementSignificant differenceReproducibility of ResultsSensory SystemsAxial Length EyeOphthalmologyInterferometryInterferometrySpain030221 ophthalmology & optometrySurgeryTomography Optical Coherence030217 neurology & neurosurgeryPartial coherenceJournal of Cataract and Refractive Surgery
researchProduct

Reliability and concurrent validity of the International Physical Activity Questionnaire short form among pregnant women

2017

Abstract Sanda B, Vistad I, Haakstad LAH, Berntsen S, Sagedal LR, Lohne-Seiler H, Torstveit MK. Reliability and concurrent validity of the International Physical Activity Questionnaire short form among pregnant women. Background The International Physical Activity Questionnaire short-form (IPAQ-SF) is frequently used to assess physical activity (PA) level in the general adult population including pregnant women. However, the reliability and validity of the questionnaire in pregnancy is unknown. Therefore, the aims of the present study were to investigate test-retest reliability and concurrent validity of IPAQ-SF among pregnant women, and whether PA is reported differently among those who fu…

medicine.medical_specialtySports medicineactivity monitorConcurrent validityAdult populationPhysical activityphysical activityPhysical Therapy Sports Therapy and Rehabilitationactivity assessmentMetabolic equivalent03 medical and health sciencesself-reported questionnaire0302 clinical medicineIPAQ-SFmedicineOrthopedics and Sports Medicine030212 general & internal medicinePregnancyexercisebusiness.industryRehabilitationLimits of agreement030229 sport sciencesmedicine.diseaseConfidence intervalPhysical therapypregnancybusinessResearch ArticleBMC Sports Science, Medicine and Rehabilitation
researchProduct

Visual acuity and contrast sensitivity screening with a new iPad application

2016

We present a new iPad application (app) for a fast assessment of Visual Acuity (VA) and Contrast Sensitivity (CS) whose reliability and agreement was evaluated versus a commercial screening device (Optec 6500). The measurement of VA was programmed in the app in accordance with the Amblyopia Treatment Study protocol. The CS was measured with sinusoidal gratings of four different spatial frequencies: 3, 6, 12 and 18 cpd at the same contrast values of the Functional Acuity Contrast Test (FACT) included in the Optec 6500. Forty-five healthy subjects with monocular corrected visual acuities better than 0.2 logMAR participated in the agreement study. Bland-Altman analyses were performed to assess…

medicine.medical_specialtyVisual acuityVisual acuitygenetic structuresComputer sciencemedia_common.quotation_subject01 natural sciences010104 statistics & probability03 medical and health sciences0302 clinical medicineOphthalmologymedicineContrast (vision)Computer visionContrast sensitivity0101 mathematicsElectrical and Electronic Engineeringmedia_commonbusiness.industryLimits of agreementHealthy subjectsFunctional acuity contrast testHuman-Computer InteractioniPadHardware and ArchitectureTreatment studyFISICA APLICADA030221 ophthalmology & optometryScreeningSpatial frequencyArtificial intelligencemedicine.symptombusinessSensitivity (electronics)