Search results for "Liquid Chromatography"

showing 10 items of 942 documents

Detection of banned drugs in sport by micellar liquid chromatography

1992

Abstract A rapid method for the determination of banned drugs in sport (including stimulants, anabolic steroids and diuretics) based on micellar liquid chromatography is proposed. The mobile phase is an aqueous solution of a surfactant (sodium dodecyl sulphate in this instance) and the stationary phase is octadecylsilica. The retention parameters of the drugs were established and the effect of a mobile phase organic modifier on the chromatographic behaviour of the compounds was studied. Improvements in efficiency were achieved by control of the temperature of the mobile phase. This method allows the direct injection of urine samples for the determination of drugs excreted free in urine: ami…

Detection limitAmiphenazoleChromatographyMethoxyphenamineChemistryMetandienoneClostebolBiochemistryAnalytical Chemistrychemistry.chemical_compoundMicellar liquid chromatographymedicineEnvironmental ChemistryEphedrineSpectroscopyPhenylpropanolaminemedicine.drugAnalytica Chimica Acta
researchProduct

Liquid Chromatographic Analysis of Amphetamine and Related Compounds in Urine Using Solid-Phase Extraction and 3,5-Dinitrobenzoyl Chloride for Deriva…

1997

A chromatographic method for the analysis of amphetamine and related compounds in urine using 3,5-dinitrobenzoyl chloride (3,5-DNB) as a labeling reagent is presented. This assay is based on the employment of solid-phase extraction (SPE) cartridges for sample cleanup and derivatization. Experimental conditions are optimized for the simultaneous derivatization of ephedrine, norephedrine, pseudoephedrine, beta-phenylethylamine, amphetamine, methamphetamine, and 3-phenylpropylamine. The derivatives formed are separated in a LiChrospher 1000 RP18 (125 x 4-mm i.d., 5-microns film thickness) analytical column using a water-acetonitrile gradient elution and detected at 254 nm. Derivatization in C1…

Detection limitAnalyteChromatographyAmphetaminesGeneral MedicinePseudoephedrineHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundchemistryNitrobenzoatesReagentmedicineIndicators and ReagentsSolid phase extractionEphedrineDerivatizationChromatography High Pressure Liquidmedicine.drugJournal of Chromatographic Science
researchProduct

Analysis of methylamine by solid-phase microextraction and HPLC after on-fibre derivatization with 9-fluorenylmethyl chloroformate

2004

Abstract A method for the determination of methylamine (MA) in aqueous matrices is reported which uses solid-phase microextraction (SPME) for enrichment and derivatization of the analyte, and high performance liquid chromatography (HPLC). The fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) has been used for derivatization. The SPME fibres were successively immersed in the samples and in the derivatization solutions to extract MA and FMOC, respectively. After a defined time of reaction, the derivatized analyte was desorbed into the chromatographic system, and chromatographed in a LiChrosphere 100 RP18, 125 mm ×4 mm i.d., 5 μm, column under gradient elution. In order to improve the…

Detection limitAnalyteChromatographyChemistryChloroformateSolid-phase microextractionBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundReagentEnvironmental ChemistrySample preparationDerivatizationSpectroscopyAnalytica Chimica Acta
researchProduct

Determination of 3-(4′-methylbenzylidene)camphor and its metabolite 3-(4′-carboxybenzylidene)camphor in human semen by solid-phase extraction and liq…

2015

An analytical method for the determination of the controversial UV filter 3-(4′-methylbenzylidene)camphor (MBC) and its metabolite 3-(4′-carboxybenzylidene)camphor (CBC) in human semen is presented. The method is based on the simultaneous hydrolysis of phase II conjugates and protein precipitation, followed by solid-phase extraction (SPE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) detection. The proposed method was validated by analyzing spiked analyte-free human semen samples. Matrix-matched calibration using an analyte-free semen pool was employed. Satisfactory recoveries (92–114%) were obtained using this calibration methodology, thus showing the accuracy of the propos…

Detection limitAnalyteChromatographyChemistryGeneral Chemical EngineeringMetaboliteGeneral EngineeringMass spectrometryAnalytical Chemistrychemistry.chemical_compoundCamphorLiquid chromatography–mass spectrometryProtein precipitationSolid phase extractionAnalytical Methods
researchProduct

High-performance liquid chromatographic determination of spironolactone and its major metabolite canrenone in urine using ultraviolet detection and c…

1994

A rapid and simple column liquid chromatographic method involving a column-switching system for the determination of spironolactone and its main metabolite canrenone in urine is described. Purification and concentration was performed using an Hypersil ODS-C18, 30 microns (20 x 2.1 mm I.D.) pre-column. The most polar urinary compounds were removed by washing the pre-column with water, and the analytes were subsequently switched to a LiChrospher RP C18, 5 microns (125 x 4 mm I.D.) analytical column and separated by means of an acetonitrile-water mobile-phase. Under the proposed conditions, the extraction efficiency was approximately 100% over the 0.5-10.0 micrograms/ml concentration range. Th…

Detection limitAnalyteChromatographyChemistryMetaboliteExtraction (chemistry)General ChemistryUrineSpironolactoneHigh-performance liquid chromatographychemistry.chemical_compoundCanrenonemedicineHumansIndicators and ReagentsSpectrophotometry UltravioletCanrenoneQuantitative analysis (chemistry)Chromatography High Pressure Liquidmedicine.drugJournal of chromatography. B, Biomedical applications
researchProduct

New micromethod combining miniaturized matrix solid-phase dispersion and in-tube in-valve solid-phase microextraction for estimating polycyclic aroma…

2008

Abstract Miniaturized matrix solid-phase dispersion (MSPD) was developed for the extraction of common polycyclic aromatic hydrocarbons (PAHs) from bivalve samples (100 mg, dry weight). Additional clean-up and analyte enrichment was accomplished by in-tube solid-phase microextraction (SPME). For this purpose the extracts collected after MSPD were diluted with water and injected into a capillary column coated with the extractive phase. This capillary column was connected to the analytical column by means of a switching valve. Separation and quantification of the PAHs were carried out using a monolithic LC column and fluorescence detection. Since the in-tube SPME device allowed the processing …

Detection limitAnalyteChromatographyChemistryOrganic ChemistryExtraction (chemistry)Analytical chemistryReproducibility of ResultsGeneral MedicineReference StandardsSolid-phase microextractionBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryBivalviaMatrix (chemical analysis)AnimalsSample preparationSolid phase extractionPolycyclic Aromatic HydrocarbonsSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

Protein mapping by two-dimensional high performance liquid chromatography.

2000

Current developments in drug discovery in the pharmaceutical industry require highly efficient analytical systems for protein mapping providing high resolution, robustness, sensitivity, reproducibility and a high throughput of samples. The potential of two-dimensional (2D) HPLC as a complementary method to 2D-gel electrophoresis is investigated, especially in view of speed and repeatability. The method will be applied for proteins of a molecular mass <20 000 which are not well resolved in 2D-gel electrophoresis. The 2D-HPLC system described in this work consisted of anion- or cation-exchange chromatography in the first dimension and reversed-phase chromatography in the second dimension. We …

Detection limitAnalyteChromatographyElutionChemistryOrganic ChemistryIon chromatographyAnalytical chemistryProteinsReproducibility of ResultsGeneral MedicineRepeatabilityReversed-phase chromatographyChromatography Ion ExchangeBiochemistryHigh-performance liquid chromatographyPeptide MappingSensitivity and SpecificityAnalytical ChemistryTwo-dimensional chromatographyChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

A direct Capillary Liquid Chromatography with electrochemical detection method for determination of phenols in water samples

2010

A fast and direct method based on the use of Capillary Liquid Chromatography (LC) with electrochemical (EC) detection has been described for phenols pollutants in water samples. Concretely, phenol, o-cresol, 2-chlorophenol and bisphenol A have been selected as target analytes. The combination of Capillary LC with EC detection avoided the necessity of preconcentration steps typically used in environmental analysis. The sample injected volume was 2 μL. The achieved detection limits were between 1 and 2 μg/L and the linear dynamic range was up to 50 μg/L for all studied phenols. The precision and uncertainty were satisfactory. The analysis time per sample was 10 min. The proposed procedure has…

Detection limitAnalyteChromatographyEnvironmental analysisCapillary actionOrganic ChemistryAnalytical chemistryReproducibility of ResultsFresh WaterGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundPhenolschemistryCapillary ElectrochromatographyLinear ModelsPhenolSeawaterPhenolsQuantitative analysis (chemistry)Water Pollutants ChemicalJournal of Chromatography A
researchProduct

A solid-phase extraction liquid chromatography-tandem mass spectrometry method for the percutaneous absorption assessment of 3-(4′-methylbenzylidene)…

2013

The UV filter 3-(4′-methylbenzylidene)camphor (MBC) is a common ingredient in sunscreen cosmetic products. However, different in vitro and in vivo studies suggest that MBC can cause endocrine disrupting effects. This report focuses on the development of an analytical method based on solid-phase extraction (SPE) prior to liquid chromatography tandem mass spectrometry (LC-MS/MS) for the determination of MBC and its main phase I metabolite, named 3-(4′-carboxybenzylidene)camphor (CBC), in urine from users of sunscreen cosmetic products containing MBC. The formation of phase II metabolites (i.e., glucuronide and sulphate conjugates) was also considered by carrying out an enzymatic hydrolysis of…

Detection limitAnalyteChromatographyGeneral Chemical EngineeringMetaboliteGeneral EngineeringAnalytical ChemistryCamphorchemistry.chemical_compoundchemistryLiquid chromatography–mass spectrometryStandard additionSolid phase extractionGlucuronideAnal. Methods
researchProduct

Automated high-performance liquid chromatographic determination of amphetamine in biological fluids using column-switching and on-column derivatizati…

1999

A rapid and simple liquid-chromatographic method has been developed for on-line quantification of amphetamine in biological fluids. Untreated samples (20 μL) are injected directly into the chromatographic system and purified on a 20 mm×2.1 mm i.d. pre-column packed with 30 μm Hypersil C18 stationary phase. After clean-up the analyte is transferred to the analytical column (125 mm×4 mm i.d., 5 μm LiChrospher 100 RP18) for derivatization and separation using a mixture of acetonitrile and the derivatization reagent (o-phthaldialdehyde andN-acetyl-L-cysteine) as the mobile phase. The experimental conditions for on-line derivatization and resolution of the amphetamine have been optimized, and th…

Detection limitAnalyteChromatographyResolution (mass spectrometry)Organic ChemistryClinical BiochemistryAnalytical chemistryBiochemistryHigh-performance liquid chromatographyFluorescence spectroscopyAnalytical Chemistrychemistry.chemical_compoundchemistryReagentDerivatizationQuantitative analysis (chemistry)Chromatographia
researchProduct