Search results for "Lumen"
showing 10 items of 149 documents
Investigation of the Effect of Duodenoscopy on Sphincter of Oddi Manometry
1991
To investigate whether endoscopy affects sphincter of Oddi (SO) manometry, three patients who had undergone previous cholecystectomy and had a T-tube in situ for drainage were studied. Manometry was performed using a perfused triple lumen manometry catheter (diameter 1.7 mm), which was advanced into the SO lumen through the T-tube. SO motility, baseline pressure, common bile duct pressure and duodenal pressure were monitored before and during endoscopy while the tip of the endoscope was in the mouth, esophagus (upper third, precardial), stomach and duodenum. Endoscopy and even a moderate insufflation of air necessary to pass the pylorus and inspect the papilla of Vater did not affect the pa…
Coronary calcium score and computed tomography coronary angiography in high-risk asymptomatic subjects: assessment of diagnostic accuracy and prevale…
2010
The aim of the study was to compare the coronary artery calcium score (CACS) and computed tomography coronary angiography (CTCA) for the assessment of non-obstructive/obstructive coronary artery disease (CAD) in high-risk asymptomatic subjects. Two hundred and thirteen consecutive asymptomatic subjects (113 male; mean age 53.6 +/- 12.4 years) with more than one risk factor and an inconclusive or unfeasible non-invasive stress test result underwent CACS and CTCA in an outpatient setting. All patients underwent conventional coronary angiography (CAG). Data from CACS (threshold for positive image: Agatston score 1/100/1,000) and CTCA were compared with CAG regarding the degree of CAD (non-obst…
Stentgraft-Implantation for Treatment of Internal Carotid Artery Injury during Endonasal Sinus Surgery
2007
Background Damage of the internal carotid artery (ICA) is very rare but can be a dramatic complication of endonasal sinus surgery. In the literature only a few cases are reported, some of them with fatal results. Methods We present two cases with massive bleeding of the ICA caused by endonasal sinus surgery. Results In both cases bleeding could be stopped sufficiently by implanting a stentgraft. Conclusion The lumen of the artery could be preserved and no neurological deficits were observed.
New balloon catheter for prolonged percutaneous transluminal coronary angioplasty and bypass flow in occluded vessels.
1986
A new balloon catheter was developed for continuous perfusion of coronary arteries during angioplasty (CPC catheter). Steerable Gruntzig balloon catheters (3.7 mm) with two lumina were formed. The first lumen was used for balloon inflation. Side holes to the second lumen proximally and distally to the balloon were created for coronary perfusion even during inflation phase. At a perfusion pressure of 120 mmHg, a flow rate of 63 +/- 3 ml/min with 0.9% saline and 43 +/- 1 ml/min with plasma expander were measured. In experiments on five dogs, dilation time until appearance of signs of ischemia could be prolonged in three of five dogs from 30 to 40 s, 120 to 203 s, and 180 to 420 s comparing co…
Nitrate-induced coronary vasodilation by stress-magnetic resonance imaging: A novel noninvasive test of coronary vasomotion
2004
Purpose To evaluate the feasibility of assessing coronary vasodilation following exogenous nitrates, using magnetic resonance angiography (MRA). The assessment of coronary response to exogenous nitrovasodilators may have a diagnostic and prognostic impact in patients with coronary artery disease. To date, stress imaging of coronary artery vasomotion has been confined to the catheterization laboratory. MRA is emerging as a noninvasive tool for coronary artery imaging. Materials and Methods Coronary MRA was performed in 20 healthy volunteers (12 males, age = 33 ± 8). We used spiral spoiled gradient echo (SSGE) sequences for imaging of coronary artery lumen. After the baseline short-axis view …
Crohn's disease: A comparative prospective study of transabdominal ultrasonography, small intestine contrast ultrasonography, and small bowel enema
2005
Background: Small intestine contrast ultrasonography (SICUS), when performed after distention of the small bowel lumen with an iso-osmolar polyethylene glycol electrolyte-balanced solution, shows high sensitivity (100%) and specificity (97%) in detecting small bowel abnormalities in patients who have not received a diagnosis but in whom there is a suspicion of intestinal diseases. The diagnostic yield of SICUS remains to be established in detecting small bowel lesions in patients with proven Crohn's disease (CD) in comparison with transabdominal ultrasonography (TUS), and in relationship to the experience of the operator, using small bowel enema (SBE) as the “gold standard.” Aim: The aim of…
Simultaneous Balloon Occlusion of the Renal Artery and Hypothermic Perfusion in in Situ Surgery of the Kidney
1978
AbstractRenal ischemia and cooling may be achieved by intraluminal balloon occlusion and intermittent hypothermic perfusion using a double lumen, balloon-tipped catheter introduced into the renal artery percutaneously. This technique was used successfully in 26 of 31 extensive nephrolithotomies, eliminating the need for dissection and clamping of the renal artery and intricate surface cooling. Intrarenal operations could be performed as effectively as with clamp occlusion. Despite a mean ischemia time of 54 minutes the individual 131I-hippuran clearance of the operated kidneys was only reduced to a mean 78.4 per cent of the preoperative value 2 to 3 weeks postoperatively and increased to 92…
The transmembrane receptor Uncoordinated5 (Unc5) is essential for heart lumen formation in Drosophila melanogaster
2011
AbstractTransport of liquids or gases in biological tubes is fundamental for many physiological processes. Our knowledge on how tubular organs are formed during organogenesis and tissue remodeling has increased dramatically during the last decade. Studies on different animal systems have helped to unravel some of the molecular mechanisms underlying tubulogenesis. Tube architecture varies dramatically in different organs and different species, ranging from tubes formed by several cells constituting the cross section, tubes formed by single cells wrapping an internal luminal space or tubes that are formed within a cell. Some tubes display branching whereas others remain linear without interse…
COMPUTATIONAL FLUID DYNAMICS OF TYPE B AORTIC DISSECTION
2014
Type B aortic dissection (AoD) is a disease connected to high blood load on the aortic wall and to a reduced aortic wall resistance. Nowadays, prognosis on type B AoD results to be particularly difficult with an high incidence of patients treated with medical therapy which manifest complication connected with dissection and which should have been treated with surgical repair immediately. This work aims to study those haemodynamical and morphological proprieties of dissected aorta, which can influence the progression or stability of type B AoD. Computational fluid-dynamic analyses were performed on twenty-five patients with type B AoD, whose nine presented an aneurysm evolution and sixteen p…
Predicting Outcome of Aortic Dissection with Patent False Lumen by Computational Flow Analysis
2014
Although Type B aortic dissection (AoD) has better in-hospital survival than Type A AoD, the short- and long term outcome for patients remains challenging, with 50–80% deaths at 5-years. Dissection-related complications include rapid aortic expansion, impending rupture, and malperfusion syndromes. We aimed to assess hemodynamic implications of patients with patent false lumen (FL) of dissected aorta. Computational fluid dynamic analyses were performed on patient-specific aortic geometries reconstructed from computed tomography scans of 25 patients with AoDs, who were admitted in our hospital from 2007 to 2013. We used the development of acute complications and chronic aneurysmal evolution a…