Search results for "Lumen"
showing 10 items of 149 documents
Lakoff & Johnson lettori di Blumenberg? Le analogie tra metaforologia e teoria della metafora concettuale
2022
This paper aims at showing the analogies between Hans Blumenberg’s Metaphorology and George Lakoff & Mark Johnson’s Conceptual Metaphor Theory. Starting from the analysis of the proportion for which ABSOLUTE METAPHOR: METAPHORICAL EXPRESSIONS = BACKGROUND METAPHOR: CONCEPTUAL METAPHOR, we propose to compare Blumenberg’s Metaphorology with Lakoff & Johnson’s Conceptual Metaphor Theory, outlining similarities and differences in reference to: (a) the fundamental notions on which the two theories are based, (b) the methods and (c) the relationship between language-thought-culture assumed by the two theories. However, the reconstruction of the relation between the two theoretical paradig…
Automatic segmentation and 3D reconstruction of intravascular ultrasound images for a fast preliminar evaluation of vessel pathologies.
2007
Abstract Intravascular ultrasound (IVUS) imaging is used along with X-ray coronary angiography to detect vessel pathologies. Manual analysis of IVUS images is slow and time-consuming and it is not feasible for clinical purposes. A semi-automated method is proposed to generate 3D reconstructions from IVUS video sequences, so that a fast diagnose can be easily done, quantifying plaque length and severity as well as plaque volume of the vessels under study. The methodology described in this work has four steps: a pre-processing of IVUS images, a segmentation of media–adventitia contour, a detection of intima and plaque and a 3D reconstruction of the vessel. Preprocessing is intended to remove …
Chronic Administration of Quercetin Induces Biomechanical and Pharmacological Remodeling in the Rat Coronary Arteries
2017
Acute dilation brought about by the dietary flavonoid quercetin in coronary arterioles has been described earlier, but no information is available on its chronic effects. Male Wistar rats (body weight about 190 g) were divided to two groups: the quercetin-treated group (n=22) had quercetin supplementation of approximately 30 mg/kg/day, whereas the control group (n=20) had none. After eight weeks of treatment, intramural coronary arterioles with identical passive diameters (178+/-14 microm and 171+/-9 microm) were prepared and their biomechanics and pharmacological reactivities were tested using pressure arteriography ex vivo. The spontaneous tone of quercetin-treated arteries was higher (16…
Direct true lumen cannulation in type A acute aortic dissection: A review of an 11 years’ experience
2020
ObjectivesDirect true lumen cannulation (DTLC) of the aorta is an alternative cardiopulmonary bypass cannulation technique in the context of type A acute aortic dissection (A-AAD). DTLC has been reported to be effective in restoring adequate perfusion to jeopardized organs. This study reports and compares operative outcomes with DTLC or alternative cannulation techniques in a large cohort of patients with A-AAD.MethodsAll patients who underwent surgery for A-AAD between January 2006 and January 2017 in Mainz university hospital were reviewed. The choice of cannulation technique was left to the operating surgeon, however DTLC was our preference in patients who were in state of shock or showe…
Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography
2006
OBJECTIVE: The purpose of this study was to investigate whether the amount of intracoronary attenuation influences the diagnostic accuracy of MDCT coronary angiography in the detection of clinically significant stenosis. MATERIALS AND METHODS: One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent MDCT of the heart and conventional coronary angiography were retrospectively selected. The population was divided into two groups depending on median (326 H) coronary vascular enhancement (i.e., low attenuation and high attenuation). The diagnostic accuracy of MDCT for the detection of clinically significant coronary artery lesions (> or = 50% lumen reduct…
When tubules aggregate
2011
Within muscle fibres, tubules appear as microtubules, transverse tubules, and different components of the sarcotubular system, the latter consisting of longitudinal tubules and lateral or terminal sacs which, at special junctional connections, are situated on both sides of transverse tubules forming triads. Pathological structures related to the transverse tubules are honeycomb structures, both the transverse tubules and the honeycomb ones being labelled by extracellularly applied lanthanum [1] or potassium ferrocyanide [2], thus, indicating an open connection between the interior of the muscle fibres and the extracellular space. Dyads or multiple incomplete or complete forms of triads, pen…
Modelling intestinal absorption of salbutamol sulphate in rats
2005
The objective was to develop a semiphysiological population pharmacokinetic model that describes the complex salbutamol sulphate absorption in rat small intestine. In situ techniques were used to characterize the salbutamol sulphate absorption at different concentrations (range: 0.15-18 mM). Salbutamol sulphate at concentration of 0.29 mM was administered in presence of verapamil (10 and 20 mM), grapefruit juice and sodium azide (NaN3) (0.3, 3 and 6 mM). Different pharmacokinetic models were fitted to the dataset using NONMEM. Parametric and non-parametric bootstrap analyses were employed as internal model evaluation techniques. The validated model suggested instantaneous equilibrium betwee…
Real-time ultrasound in Crohn's disease: characteristic features and clinical implications.
1986
Thirty-two children with Crohn's disease were evaluated by real-time ultrasonography. The typical pattern of Crohn's disease caused by bowel wall thickening is the “bull's eye phenomenon”, the elongated tubular stiff bowel loop with narrowing of the lumen and the small bowel conglomerate tumor. In indefinable abdominal complaints sonography may lead to the correct diagnosis. The differential diagnosis of similar sonographic features and the limitations of ultrasound in gastrointestinal disease must be considered. In proven Crohn's disease the findings in follow-up match the clinical course and may delineate complications, such as ileus, abscess, hydronephrosis, gallstones or involvement of …
Reproducible coronary plaque quantification by multislice computed tomography
2007
BACKGROUND: The aim of this study was to investigate reproducibility and accuracy of computer-assisted coronary plaque measurements by multislice computed tomography coronary angiography (QMSCT-CA). METHODS AND RESULTS: Forty-eight patients undergoing MSCT-CA and coronary arteriography for symptomatic coronary artery disease and quantitative intravascular ultrasound (IVUS, QCU) were examined. Two investigators performed the QMSCT-CA twice and a third investigator performed the QCU, all blinded for each other's results. There was no difference found for the matched region of interest (ROI) lengths (QCU 29.4 +/- 13 mm vs. QMSCT-CA 29.6 +/- 13 mm, P = 0.6; total length = 1,400 mm). The compari…
Pulmonary effects of expiratory-assisted small-lumen ventilation during upper airway obstruction in pigs
2015
Summary Novel devices for small-lumen ventilation may enable effective inspiration and expiratory ventilation assistance despite airway obstruction. In this study, we investigated a porcine model of complete upper airway obstruction. After ethical approval, we randomly assigned 13 anaesthetised pigs either to small-lumen ventilation following airway obstruction (n = 8) for 30 min, or to volume-controlled ventilation (sham setting, n = 5). Small-lumen ventilation enabled adequate gas exchange over 30 min. One animal died as a result of a tension pneumothorax in this setting. Redistribution of ventilation from dorsal to central compartments and significant impairment of the distribution of ve…