Search results for "Lung"
showing 10 items of 2389 documents
Pancoast tumour: current therapeutic options
2019
Pancoast's syndrome is caused by malignant neoplasm of superior sulcus of the lung which produces destructive lesions of thoracic inlet and comes along with the involvement of brachial plexus and stellate ganglion. Computed tomography (CT) or magnetic resonance imaging (MRI) scans can detect early lesions otherwise missed by routine radiographs and can also define the local extent or metastatic progression of the disease. Protocols involving combinations of irradiation, chemotherapy, and surgery are currently being under investigation to determine the best management.This work reviewed the current diagnostic and therapeutic approaches to Pancoast's tumors.Patients with lung superior sulcus …
Bilateral lung and liver hydatid cyst
2012
Introduction. Thymomas (THs) are rare epithelial tumors of the thymus gland. In this study we report our personal experience in the management and surgical treatment of THs. Case reports. We report two clinical cases treated with combined therapy (surgery followed by adjuvant therapy). Results. Total transternal thymectomy was performed in both patients. The post-operative course was uneventful. The patients received adjuvant radiotherapy and chemotherapy. No relapse has been observed during follow-up. Discussion. THs are usually slowly growing tumors with similar incidence in both sexes. They occur through a wide age range, with a peak in the fifth and sixth decades. Distinctive features r…
Resection of a giant mediastinal leiomyosarcoma
2019
ABSTRACT Primary leiomyosarcomas of the lung are rare tumors. We report a case of 49-year-old female with history of cough, breathless at rest, right sided chest pain. Chest CT showed a huge (16 cm) mediastinal mass located on the right mediastinum encasing the right main pulmonary artery and infiltrating the main right bronchus and pericardium. The tumor was resected with combined pericardiectomy and pnemonectomy via hemiclamshell incision. This surgical access provided an adequate exposure of the chest “blind zones” and it allowed a radical and safe surgical resection of lung, pleura, pericardium and diaphragm. The final diagnosis showed a low grade differentiation leiomyosarcoma.
Intrapulmonary 3He Gas Distribution Depending on Bolus Size and Temporal Bolus Placement
2008
OBJECTIVE: Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on inspiratory gas distribution. MATERIALS AND METHODS: An ultrafast 2-dimensional spoiled gradient echo sequence (temporal resolution 100 milliseconds) was used for dynamic ventilation (3)He-MRI of 11 anesthetized and mechanically ventilated pigs. The applied (3)He gas bolus was varied in volume between 100 and 200 mL. A 150-mL bolus was varied in its application time after the beg…
Anam-Net: Anamorphic Depth Embedding-Based Lightweight CNN for Segmentation of Anomalies in COVID-19 Chest CT Images.
2021
Chest computed tomography (CT) imaging has become indispensable for staging and managing coronavirus disease 2019 (COVID-19), and current evaluation of anomalies/abnormalities associated with COVID-19 has been performed majorly by the visual score. The development of automated methods for quantifying COVID-19 abnormalities in these CT images is invaluable to clinicians. The hallmark of COVID-19 in chest CT images is the presence of ground-glass opacities in the lung region, which are tedious to segment manually. We propose anamorphic depth embedding-based lightweight CNN, called Anam-Net, to segment anomalies in COVID-19 chest CT images. The proposed Anam-Net has 7.8 times fewer parameters …
Development of a novel rapamycin loaded nano- into micro-formulation for treatment of lung inflammation
2022
AbstractIt has recently emerged that drugs such as the mTOR inhibitor rapamycin (Rapa) may play a key role in the treatment of airway inflammation associated with lung diseases, such as chronic obstructive pulmonary disease, asthma, and cystic fibrosis. Nevertheless, Rapa clinical application is still prevented by its unfavorable chemical-physical properties, limited oral bioavailability, and adverse effects related to non-specific biodistribution. In this paper, the design and production of a novel formulation of Rapa based on nano into micro (NiM) particles are detailed. To achieve it, Rapa-loaded nanoparticles were produced by nanoprecipitation of an amphiphilic pegylated poly-ɛ-caprolac…
BIBF 1120/ nintedanib : a new triple angiokinase inhibitor-directed therapy in patients with non-small cell lung cancer.
2013
Abstract: Introduction: Several new targeted agents with anti-angiogenic properties have been developed recently, including vandetanib, sunitinib, sorafenib, bevacizumab and others. Tumor development, progression, metastasis are strongly linked to angiogenesis. Targeted agents like bevacizumab, a monoclonal antibody which targets VEGF, have been fully developed in several solid tumors. These new agents strongly advocate that targeting angiogenesis is one of the best approaches for cancer therapy. Areas covered: Those agents that target additional pro-angiogenic intracellular signaling pathways beyond VEGF signaling have also the potential to contribute to anticancer therapies. The authors p…
A high-Q superconducting toroidal medium frequency detection system with a capacitively adjustable frequency range >180 kHz
2022
We describe a newly developed polytetrafluoroethylene/copper capacitor driven by a cryogenic piezoelectric slip-stick stage and demonstrate with the chosen layout cryogenic capacitance tuning of ≈60 pF at ≈10 pF background capacitance. Connected to a highly sensitive superconducting toroidal LC circuit, we demonstrate tuning of the resonant frequency between 345 and 685 kHz, at quality factors Q > 100 000. Connected to a cryogenic ultra low noise amplifier, a frequency tuning range between 520 and 710 kHz is reached, while quality factors Q > 86 000 are achieved. This new device can be used as a versatile image current detector in high-precision Penning-trap experiments or as …
Production of highly charged ions of rare species by laser-induced desorption inside an electron beam ion trap
2019
This paper reports on the development and testing of a novel, highly efficient technique for the injection of very rare species into electron beam ion traps (EBITs) for the production of highly charged ions (HCI). It relies on in-trap laser-induced desorption of atoms from a sample brought very close to the electron beam resulting in a very high capture efficiency in the EBIT. We have demonstrated a steady production of HCI of the stable isotope 165Ho from samples of only 1012 atoms (∼300 pg) in charge states up to 45+. HCI of these species can be subsequently extracted for use in other experiments or stored in the trapping volume of the EBIT for spectroscopic measurements. The high efficie…
The cryogenic gas stopping cell of SHIPTRAP
2014
The overall efficiency of the Penning-trap mass spectrometer SHIPTRAP at GSI Darmstadt, employed for high-precision mass measurements of exotic nuclei in the mass region above fermium, is presently mostly limited by the stopping and extraction of fusion-evaporation products in the SHIPTRAP gas cell. To overcome this limitation a second-generation gas cell with increased stopping volume was designed. In addition, its operation at cryogenic temperatures leads to a higher gas density at a given pressure and an improved cleanliness of the helium buffer gas. Here, the results of experiments with a 219Rn recoil ion source are presented. An extraction efficiency of 74(3)% was obtained, a significa…