Search results for "Lung"

showing 10 items of 2389 documents

The performance of the cryogenic buffer-gas stopping cell of SHIPTRAP

2018

Direct high-precision mass spectrometry of the heaviest elements with SHIPTRAP, at GSI in Darmstadt, Germany, requires high efficiency to deal with the low production rates of such exotic nuclides. A second-generation gas stopping cell, operating at cryogenic temperatures, was developed and recently integrated into the relocated system to boost the overall efficiency. Offline measurements using 223Ra and 225Ac recoil-ion sources placed inside the gas volume were performed to characterize the gas stopping cell with respect to purity and extraction efficiency. In addition, a first online test using the fusion-evaporation residue 254No was performed, resulting in a combined stopping and extrac…

Speichertechnik - Abteilung BlaumNuclear and High Energy PhysicsMaterials scienceDIRECT MASS MEASUREMENTSProtonBuffer gaschemistry.chemical_elementPenning trapsMass spectrometry7. Clean energy01 natural sciencesFusion-evaporation reaction productsNuclear physicsIonization0103 physical sciencesCalibrationStopping and extraction efficiencyNuclide010306 general physicsInstrumentationCALIBRATION[PHYS]Physics [physics]nobeliumSPECTROSCOPYMass spectrometry010308 nuclear & particles physicsTransfermium elementsCryogenic gas stopping cellExtraction timeHEAVIEST ELEMENTSchemistryIONIZATIONNobeliumOrder of magnitude
researchProduct

A reservoir trap for antiprotons

2015

We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measurements. In our trap-system antiproton storage times > 1.08 years are estimated. The device is fail-safe against power-cuts of up to 10 hours. This makes our planned comparisons of the fundamental properties of protons and antiprotons independent from accelerator cycles, and will enable us to perform experiments during long accelerator shutdown periods when background magnetic noise is low. The demonstrated scheme has the potential to be applied in many other precision Penning trap experiments dealing with exotic p…

Speichertechnik - Abteilung BlaumPhysics - Instrumentation and DetectorsMagnetic noiseAtomic Physics (physics.atom-ph)Other Fields of PhysicsFOS: Physical sciences7. Clean energy01 natural sciencesIon trappingphysics.atom-ph010305 fluids & plasmasPhysics - Atomic PhysicsNuclear physicsTrap (computing)0103 physical sciencesPhysics::Atomic PhysicsPhysical and Theoretical ChemistryDetectors and Experimental Techniques010306 general physicsNuclear ExperimentInstrumentationphysics.ins-detSpectroscopyPhysicsInstrumentation and Detectors (physics.ins-det)Condensed Matter PhysicsPenning trapAntiprotonPhysics::Accelerator Physics
researchProduct

Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment

2018

The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at − 18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two [superscript 83m]Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN’s commissioning measurements in July 2…

Speichertechnik - Abteilung BlaumPhysics - Instrumentation and DetectorsPhysics and Astronomy (miscellaneous)FOS: Physical sciences7. Clean energy01 natural sciencesNuclear physics0103 physical sciencesCalibrationddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsEngineering (miscellaneous)[ PHYS.PHYS.PHYS-INS-DET ] Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]PhysicsTeoría de los quantaSpectrometer010308 nuclear & particles physicsPhysicsVoltage dividerInstrumentation and Detectors (physics.ins-det)MetrologyNeutrinoEnergy (signal processing)VoltageKATRIN
researchProduct

Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment

2018

Arenz, M., et al. “Reduction of Stored-Particle Background by a Magnetic Pulse Method at the KATRIN Experiment.” The European Physical Journal C, vol. 78, no. 9, Sept. 2018. © 2018 The Authors

Speichertechnik - Abteilung BlaumPhysics - Instrumentation and DetectorsPhysics and Astronomy (miscellaneous)Field (physics)Physics::Instrumentation and DetectorsFOS: Physical scienceslcsh:AstrophysicsElectronKATRIN01 natural sciencesradon: nuclideNeutrino mass0103 physical scienceslcsh:QB460-466coillcsh:Nuclear and particle physics. Atomic energy. Radioactivityddc:530Sensitivity (control systems)[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsnumerical calculationsEngineering (miscellaneous)background: radioactivitybackground: suppressionPhysicsSpectrometer010308 nuclear & particles physicsPhysicsOrder (ring theory)Monte Carlo methodsInstrumentation and Detectors (physics.ins-det)Radon backgroundPulse (physics)13. Climate actionBackground reduction methodsPartículaslcsh:QC770-798spectrometerAtomic physicsElectricidadElectron neutrinoKATRIN
researchProduct

Suppression of Penning discharges between the KATRIN spectrometers

2020

The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)neutrino mass with a sensitivity of $0.2\textrm{ eV/c}^2$ (90$\%$ C.L.) by precisely measuring the endpoint region of the tritium $\beta$-decay spectrum. It uses a tandem of electrostatic spectrometers working as MAC-E (magnetic adiabatic collimation combined with an electrostatic) filters. In the space between the pre-spectrometer and the main spectrometer, an unavoidable Penning trap is created when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create a…

Speichertechnik - Abteilung BlaumPhysics - Instrumentation and DetectorsPhysics and Astronomy (miscellaneous)Physics::Instrumentation and DetectorsPenning trapFOS: Physical scienceslcsh:AstrophysicsSuperconducting magnetElectronTritiumKATRIN01 natural sciencesNuclear physics0103 physical scienceslcsh:QB460-466lcsh:Nuclear and particle physics. Atomic energy. RadioactivityElectron Captureddc:530[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsNuclear ExperimentEngineering (miscellaneous)PhysicsSpectrometer010308 nuclear & particles physicsPhysicsInstrumentation and Detectors (physics.ins-det)Químicamagnet: superconductivityspectrometer: electrostaticPenning trapBeamlineBeta (plasma physics)electron: backgroundlcsh:QC770-798NeutrinoNeutrino MassKATRIN
researchProduct

Gamma-induced background in the KATRIN main spectrometer

2019

The KATRIN experiment aims to measure the effective electron antineutrino mass $$m_{\overline{\nu }_e}$$ mν¯e with a sensitivity of $${0.2}\,{\hbox {eV}/\hbox {c}^2}$$ 0.2eV/c2 using a gaseous tritium source combined with the MAC-E filter technique. A low background rate is crucial to achieving the proposed sensitivity, and dedicated measurements have been performed to study possible sources of background electrons. In this work, we test the hypothesis that gamma radiation from external radioactive sources significantly increases the rate of background events created in the main spectrometer (MS) and observed in the focal-plane detector. Using detailed simulations of the gamma flux in the e…

Speichertechnik - Abteilung BlaumPhysics - Instrumentation and Detectorsgamma ray: backgroundshieldingshielding: magneticPhysicsFOS: Physical scienceslcsh:AstrophysicsInstrumentation and Detectors (physics.ins-det)electron: secondarysensitivityKATRINbackground: lowlcsh:QB460-466electron: backgroundlcsh:QC770-798lcsh:Nuclear and particle physics. Atomic energy. Radioactivityddc:530gamma ray: flux[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Electromagnetismonumerical calculationselectrostatic
researchProduct

Physician's mistakes in the interpretation of spirometry

2012

Background. The most recent ATS/ERS recommendations on lung function testing include a definition of airflow obstruction based on lower limit of normal (LLN) of FEV1/FVC and suggest to measure total lung capacity (TLC) in suspected cases of “pseudo-restriction” (normal FEV1/FVC ratio because of concomitant reductions in FEV1 and FVC), that can conceal airflow obstruction if the subject does not exhale long enough. Aims. To evaluate the skill of physicians in the interpretation of spirometry. Methods. A questionnaire focusing on the interpretation of five spirograms was administered to 127 physicians (aged 25-67yrs; 39% pulmonologists, 20% geriatrics). Correlates of spirometric misinterpreta…

Spirometry COPD - diagnosis Lung function testing
researchProduct

Prenatal exposure to organochlorine compounds and lung function during childhood

2019

Introduction: Prenatal exposure to organochlorine compounds (OCs) can increase the risk of reported respiratory symptoms in children. It remains unclear whether these compounds can also impact on lung function. We assessed the association between prenatal exposure to OCs and lung function during childhood. Methods: We included 1308 mother-child pairs enrolled in a prospective cohort study. Prenatal concentrations of p,p′-dichlorodiphenyltrichloroethane [p,p′-DDT], p,p′-dichlorodiphenyldichloroethylene [p,p′-DDE], hexachlorobenzene [HCB], and seven polychlorinated biphenyls [PCBs] were measured in cord blood. Spirometry was performed in the offspring at ages 4 (n = 636) and 7 years (n = 1192…

Spirometry010504 meteorology & atmospheric sciencesOffspringPhysiology010501 environmental sciences01 natural sciencesFEV1/FVC ratioPregnancyStatistical significancePrenatal exposuremedicineHydrocarbons ChlorinatedHumansProspective StudiesRespiratory systemProspective cohort studyChildLungChildrenlcsh:Environmental sciences0105 earth and related environmental sciencesGeneral Environmental Science2. Zero hungerlcsh:GE1-350PregnancyDichlorodiphenyldichloroethylenemedicine.diagnostic_testbusiness.industryrespiratory systemOrganochlorine compoundsmedicine.diseaseFetal BloodLung function3. Good healthRespiratory Function Testsrespiratory tract diseasesQuartileChild PreschoolPrenatal Exposure Delayed EffectsFemalebusinessBirth cohort
researchProduct

SNPs associated withHHIPexpression have differential effects on lung function in males and females

2019

AbstractAdult lung function is highly heritable and 279 genetic loci were recently reported as associated with spirometry-based measures of lung function. Though lung development and function differ between males and females throughout life, there has been no genome-wide study to identify genetic variants with differential effects on lung function in males and females. Here, we present the first genome-wide genotype-by-sex interaction study on four lung function traits in 303,612 participants from the UK Biobank. We detected five SNPs showing genome-wide significant (P<5 × 10−8) interactions with sex on lung function, as well as 21 suggestively significant interactions (P<1 × 10−6). T…

Spirometry0303 health sciencesCOPDmedicine.medical_specialtyLungmedicine.diagnostic_testSingle-nucleotide polymorphismBiologymedicine.disease03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureEndocrinology030228 respiratory systemInternal medicinemedicineSNPAlleleBeta (finance)Lung function030304 developmental biology
researchProduct

Airway obstruction in relation to symptoms in chronic respiratory disease—a nationally representative population study

2000

Abstract We examined the severity of airway obstruction and the occurrence of respiratory symptoms in a large, nationally representative population sample and in a subgroup of subjects with chronic bronchitis and/or emphysema to obtain information for developing national prevention and treatment strategies for these diseases. The study population comprised of 7217 randomly selected subjects (aged 30 years and older) who participated in a comprehensive health examination survey. The ‘cases' were subjects diagnosed as having chronic bronchitis and/or emphysema. The survey methods comprised of questionnaires, interviews, physical measurements, including spirometry, and clinical examinations. I…

SpirometryAdultMalePulmonary and Respiratory Medicinemedicine.medical_specialtyChronic bronchitissymptoms.chronic obstructive pulmonary diseaseFEV1/FVC ratioInternal medicineForced Expiratory VolumeSurveys and QuestionnairesOdds RatioPrevalenceMedicineHumansLung Diseases ObstructiveBronchitisFinlandAgedEmphysemamedicine.diagnostic_testbusiness.industryPhlegmRespiratory diseaseSmokinglung functionAirway obstructionMiddle Agedrespiratory systemmedicine.diseaseobstructionrespiratory tract diseasesCold TemperatureChronic coughDyspneaPopulation SurveillanceChronic DiseasePhysical therapyPopulation studychronic bronchitisFemalemedicine.symptombusinessRespiratory Medicine
researchProduct