Search results for "Lytic"

showing 10 items of 11146 documents

Optimised procedures for the reversed-phase liquid chromatographic analysis of formulations containing tricyclic antidepressants.

2003

The chromatographic behaviour (retention, selectivity, peak shape and resolution) of seven tricyclic antidepressants (TCAs), amitryptiline, clomipramine, doxepin, imipramine, maprotiline, nortryptiline and trimipramine, was examined. Conventional unendcapped Cs and C18 columns and an endcapped XTerra MS C18 column recommended for the analysis of basic compounds were used together with acetonitrile-water and micellar sodium dodecylsulfate (SDS)-pentanol mobile phases. The two best combinations were XTerra C18/acetonitrile, which yielded the largest efficiencies and resolution, and C8/SDS-pentanol, which eliminated the peak tails that were still observed with the XTerra C18 column. Both the s…

AcetonitrilesResolution (mass spectrometry)Clinical BiochemistryPharmaceutical ScienceCapsulesAntidepressive Agents TricyclicSensitivity and SpecificityDosage formAnalytical Chemistrychemistry.chemical_compoundDrug DiscoverymedicineAcetonitrileSpectroscopyChromatography High Pressure LiquidChromatographyExtraction (chemistry)Reproducibility of ResultsReversed-phase chromatographyDoxepinTrimipraminechemistry1-PentanolSolventsmedicine.drugTabletsJournal of pharmaceutical and biomedical analysis
researchProduct

Reversed phase liquid chromatography for the enantioseparation of local anaesthetics in polysaccharide-based stationary phases. Application to biodeg…

2020

[EN] A comprehensive study on the chiral separation of bupivacaine, mepivacaine, prilocaine and propanocaine with eight commercial polysaccharide-based chiral stationary phases (CSPs) in reversed phase conditions compatible with MS detection is performed. Methanol and acetonitrile are used as organic modifiers. Retention and resolution values obtained for each compound in the different CSPs and mobile phases are compared. The polysaccharide-based CSPs tested present different enantioselectivity towards the analytes. From the results, the experimental conditions for determining the enantiomers of bupivacaine, mepivacaine, prilocaine and propanocaine in saline aqueous samples using MS detecti…

AcetonitrilesResolution (mass spectrometry)Mepivacaine010402 general chemistry01 natural sciencesBiochemistryAnalytical Chemistrychemistry.chemical_compoundReversed phase conditionsPolysaccharidesPhase (matter)medicineEnantioselective biodegradation studyAnesthetics LocalAcetonitrileLocal anaestheticsChromatography High Pressure LiquidChromatography Reverse-PhaseAqueous solutionChromatographyCellulose and amylose-based chiral stationary phasesMethanol010401 analytical chemistryOrganic ChemistryEnantioselective synthesisWaterStereoisomerismGeneral MedicineReversed-phase chromatography0104 chemical sciencesMolecular WeightBiodegradation EnvironmentalchemistryEnantiomermedicine.drugJournal of chromatography. A
researchProduct

A capillary liquid chromatography method for benzalkonium chloride determination as a component or contaminant in mixtures of biocides

2015

A method for quantifying benzalkonium chloride (BAK), an alkyl dimethyl benzyl ammonium compound, in several biocides formulations is proposed. A tertiary amine like N-(3-aminopropyl)-N-dodecyl-1,3-propanediamine (TA) and a straight-chain alkyl ammonium compound like trimethyl-tetradecyl ammonium chloride (TMTDAC), have been employed as trade surfactants besides BAK. Two capillary analytical columns with different polarities are tested: inertsil CN-3 capillary column (150mm×0.5mm i.d., 3μm particle diameter) and a non endcapped Zorbax C18 capillary column (35mm×0.5mm i.d., 5μm particle diameter). This latter column provided the best separation of the BAK homologues in less than 12min using …

AcetonitrilesTertiary amineCapillary action02 engineering and technologySolid-phase microextraction01 natural sciencesBiochemistryChemistry Techniques AnalyticalAnalytical ChemistrySurface-Active Agentschemistry.chemical_compoundBenzalkonium chlorideLimit of DetectionmedicineAmmoniumAcetonitrileSolid Phase MicroextractionAlkylchemistry.chemical_classificationChromatography010401 analytical chemistryOrganic ChemistryGeneral Medicine021001 nanoscience & nanotechnology0104 chemical scienceschemistryAmmonium chlorideBenzalkonium Compounds0210 nano-technologyChromatography LiquidDisinfectantsmedicine.drugJournal of Chromatography A
researchProduct

Sample Preparation Improvement in Polycyclic Aromatic Hydrocarbons Determination in Olive Oils by Gel Permeation Chromatography and Liquid Chromatogr…

2005

Abstract The determination of 15 polycyclic aromatic hydrocarbons (PAHs) in olive oil samples has been improved in order to obtain a fast methodology with a low limit of detection through the combination of liquid–liquid extraction with acetonitrile and preparative gel permeation chromatography (GPC) prior to the injection of purified extracts into a C18 column. Acetonitrile–water was used as the mobile phase with a gradient from 50 to 95%, w/w, acetonitrile in 30 min. The oven temperature was maintained at 15°C, and fluorometric detection was made at a fixed excitation wavelength of 264 nm and variable, optimal emission wavelength for each analyte ranging from 352 nm for 11-H-benzo(b)fluor…

AcetonitrilesTime FactorsFluoreneChemistry Techniques AnalyticalAnalytical ChemistryGel permeation chromatographychemistry.chemical_compoundPlant OilsEnvironmental ChemistryFluorometryUltrasonicsSample preparationPolycyclic Aromatic HydrocarbonsOlive OilChromatography High Pressure LiquidPharmacologychemistry.chemical_classificationDetection limitFluorantheneFluorenesMethylene ChlorideChromatographyChemistryExtraction (chemistry)TemperatureSilicon DioxideSpectrometry FluorescenceHydrocarbonChromatography GelPyreneAgronomy and Crop ScienceChromatography LiquidFood ScienceJournal of AOAC INTERNATIONAL
researchProduct

Agrobacterium tumefaciens-mediated genetic transformation of the cardenolide-producing plant Digitalis minor L.

2003

A repeatable transformation system has been established for Digitalis minor using Agrobacterium tumefaciens. Leaf explants from 30-day-old seedlings were inoculated with either EHA105 (carrying the nptII and gusA genes) or AGL1 (with the bar and gusA genes) strains. Among the tested factors influencing T-DNA transfer to plants, the EHA105 strain and the addition of acetosyringone to the co-culture medium increased transformation. The highest transformation efficiency (8.4%) was obtained when freshly isolated explants, soaked in a bacterial suspension with an OD 550 of 0.9, were subcultured on selection medium after a 4-day co-culture with the bacteria. Evidence of stable transgene integrati…

AcetosyringoneAgrobacteriumPharmaceutical ScienceGenetically modified cropsBiologyAnalytical Chemistrychemistry.chemical_compoundTransformation GeneticDrug DiscoveryBotanyCardenolideHumansPharmacologyDigitalisfungiOrganic Chemistryfood and beveragesAgrobacterium tumefaciensbiology.organism_classificationPlants Genetically ModifiedPlant LeavesTransformation (genetics)Complementary and alternative medicinechemistryAgrobacterium tumefaciensMolecular MedicineTransformation efficiencyExplant culturePlanta medica
researchProduct

Ferro-pedrizite, NaLi2(Fe2+ 2Al2Li)Si8O22(OH)2, a new amphibole-supergroup mineral from the Sutlug pegmatite, Tyva Republic, Russia

2015

Ferro-pedrizite, a new amphibole-supergroup mineral was discovered in the Sutlug pegmatite occurrence situated in the Targi River Basin, Tyva Republic, Eastern Sibera, Russia. The associated minerals are quartz, albite, microcline, spodumene, cassiterite, beryl, columbite-(Mn), fergusonite-β-(Y), fluorapatite, schorl, trilithionite and fluorite. Ferro-pedrizite forms dark grey-blue to violet-blue acicular and long prismatic crystals up to 2 × 5 × 50 mm and their aggregates. D meas = 3.16(1) g/cm3 (by hydrostatic weighing), 3.13(1) g/cm3 (by flotation in heavy liquids); D calc = 3.135 g/cm3. Ferro-pedrizite is optically biaxial (−), α = 1.614(3), β = 1.638(3), γ = 1.653(3), 2 V meas = 75(5)°…

AcicularMicroclineChemistryCassiteriteAnalytical chemistryMineralogyминералыТуваengineering.materialпегматитыSpodumeneAlbiteGeochemistry and PetrologyengineeringChemical compositionAmphibolePegmatiteEuropean Journal of Mineralogy
researchProduct

Crystal fabrics and element impurities (Sr/Ca, Mg/Ca, and Ba/Ca) in shells of Arctica islandica—Implications for paleoclimate reconstructions

2013

Sr/Ca, Mg/Ca and Ba/Ca values are heterogeneously distributed in shells of Arctica islandica. These patterns are largely associated with crystal fabrics (size, habit and orientation of crystals) or the processes controlling them. The outer sublayer of the outer shell layer (oOSL; homogenous and irregular simple prismatic crystal fabrics,) contained element/Ca values up to 62% higher than the inner sublayer (iOSL; crossed-acicular, crossed-lamellar, fine crossed-lamellar and irregular simple prismatic crystal fabrics). A gradual decrease in Sr/Ca and Mg/Ca values was observed from the outer portions of the oOSL toward the oOSL/iOSL transition zone. This chemical shift was accompanied by a gr…

AcicularbiologyAnalytical chemistryPaleontologyMineralogyOceanographybiology.organism_classificationCrystalImpurityTransition zoneSeawaterBivalve shellArctica islandicaEcology Evolution Behavior and SystematicsGeologyEarth-Surface ProcessesBiomineralizationPalaeogeography, Palaeoclimatology, Palaeoecology
researchProduct

Can Macroscopic Parameters, Such as Conversion and Selectivity, Distinguish between Different Cracking Mechanisms on Acid Catalysts?

1997

n-heptane cracking has been carried out for very short time periods on an established reaction mechanism which includes the following group of stream reactions on different zeolites: Initiation reactions (protolytic cracking), charge isomerization, chain isomerization, hydride transfer, β-scission–alkylation, desorption–adsorption, and hydrogen transfer–cyclization. It has been observed that a given experimental distribution of products can be explained by more than just one reaction scheme. This does not allow one to clearly distinguish the fraction of reactant which disappears via monomolecular initiation reactions with respect to bimolecular hydride transfer reactions.

Acid catalysisReaction mechanismCrackingHydrogenChemistryHydridechemistry.chemical_elementPhysical and Theoretical ChemistryPhotochemistryFluid catalytic crackingIsomerizationCatalysisCatalysisJournal of Catalysis
researchProduct

Some observations on the determination of total heavy metals in sewage sludge by atomic absorption spectrophotometry after a pressurized acid digesti…

1990

Abstract An economical and simple method for the flame atomic absorption spectrometric determination of Cd, Pb, Ni, Cu, Fe, and Zn in sewage sludges is described. Samples are treated with concentrated HNO 3 in a thermal oven using Pyrex glass tubes hermetically sealed with Bakelite screw caps. The effect of the digestion parameters, such as digestion time, acid volume, sample mass, and temperature, were studied. The precision and accuracy of this procedure were evaluated by the analysis of two BCR (Community Bureau of Reference, European Communities) certified sewage sludge samples (CRM 146 and 144).

Acid digestionChemistrybusiness.industryAnalytical chemistrySewageHeavy metalsAnalytical Chemistrylaw.inventionchemistry.chemical_compoundDigestion (alchemy)Volume (thermodynamics)lawBakelitebusinessAtomic absorption spectroscopySpectroscopySludgeNuclear chemistryMicrochemical Journal
researchProduct

Flame atomic absorption analysis of gold in jewelry samples

1990

A new procedure is proposed for the determination of gold by flame atomic absorption in jewelry samples. The method is based on the acid digestion of 10 mg of sample in a microwave oven and on the on-line dilution, using a three-way valve. The dynamic range of the technique is extended to 100 mg/l gold solutions and using a weighted bracketing method for the treatment of the results, accuracy errors lower than 2% can be found in the analysis of real samples as compared with those obtained by fire assay. The method is very fast and implies only little damage to the jewelry samples.

Acid digestionChemistrylawDynamic rangeMicrowave ovenSample (material)Analytical chemistryAtomic absorption spectroscopyBiochemistryMicrowaveDilutionlaw.inventionFresenius' Journal of Analytical Chemistry
researchProduct