Search results for "MAGNETIC FIELD"
showing 10 items of 1488 documents
EFFECTS OF THE STATIC MAGNETIC FIELD GENERATED BY A 1.5 T MRI UNIT ON TNF ALFA RELEASE AND TNF RECEPTOR II EXPRESSION OF HUMAN MONOCYTES.
2008
Strain-mediated electric-field control of exchange bias in a Co90Fe10/BiFeO3/SrRuO3/PMN-PT heterostructure.
2015
AbstractThe electric-field (E-field) controlled exchange bias (EB) in a Co90Fe10/BiFeO3 (BFO)/SrRuO3/PMN-PT heterostructure has been investigated under different tensile strain states. The in-plane tensile strain of the BFO film is changed from +0.52% to +0.43% as a result of external E-field applied to the PMN-PT substrate. An obvious change of EB by the control of non-volatile strain has been observed. A magnetization reversal driven by E-field has been observed in the absence of magnetic field. Our results indicate that a reversible non-volatile E-field control of a ferromagnetic layer through strain modulated multiferroic BFO could be achieved at room temperature.
Field-driven domain wall motion under a bias current in the creep andflow regimes in Pt/[CoSiB/Pt](N) nanowires
2016
AbstractThe dynamics of magnetic domain wall (DW) in perpendicular magnetic anisotropy Pt/[CoSiB/Pt]N nanowires was studied by measuring the DW velocity under a magnetic field (H) and an electric current (J) in two extreme regimes of DW creep and flow. Two important findings are addressed. One is that the field-driven DW velocity increases with increasing N in the flow regime, whereas the trend is inverted in the creep regime. The other is that the sign of spin current-induced effective field is gradually reversed with increasing N in both DW creep and flow regimes. To reveal the underlying mechanism of new findings, we performed further experiment and micromagnetic simulation, from which w…
Multipactor Analysis in Coaxial Waveguides for Satellite Applications using Frequency-Domain Methods
2006
This work presents the analysis, manufacturing and testing of a coaxial sample in order to investigate the multipactor effect in this kind of waveguide structures. Several in-home and commercial software have been used to design a quarter-wave transformer coaxial circuit centered at 1.35 GHz. The multipactor analysis of this device has been carried out allowing the prediction of the RF breakdown multipactor threshold. Moreover, the multipactor onset of such a prototype has been measured showing a very good agreement with our simulations. In addition to this, comparison has been also done with results from the technical literature fully validating the new algorithm developed.
Analysis of Multipactor Effect in a Partially Dielectric-Loaded Rectangular Waveguide
2019
This paper 1 presents a study of the multipactor 2 effect in a partially dielectric-loaded rectangular waveguide. 3 To obtain the simulations presented in this paper, a detailed 4 analysis of the dynamics of the electron inside this waveguide 5 has been performed, taking into account the radio frequency 6 electromagnetic fields propagating in the waveguide and the dc 7 electric field that appears because of the charging of the dielectric 8 layer. This electrostatic field is obtained by computing the electric 9 potential produced by an arbitrary charge distribution on the 10 dielectric layer in a dielectric-loaded waveguide. The electron 11 trajectory is then found by numerically solving the…
Multipactor Mitigation in Coaxial Lines by Means of Permanent Magnets
2014
The main aim of this paper is the analysis of the feasibility of employing permanent magnets for the multipactor mitigation in a coaxial waveguide. First, the study of a coaxial line immersed in a uniform axial magnetic field shows that multipactor can be suppressed at any RF if the external magnetic field is strong enough. Both theoretical simulations and experimental tests validate this statement. Next, multipactor breakdown of a coaxial line immersed in a hollow cylindrical permanent magnet is analyzed. Numerical simulations show that multipactor can be suppressed in a certain RF range. The performed experimental test campaign demonstrates the capability of the magnet to avoid the multip…
An analytical model to evaluate the radiated power spectrum of a multipactor discharge in a parallel-plate region
2008
This paper is aimed at studying the electromagnetic radiation pattern of a multipactor discharge occurring in a parallel-plate waveguide. The proposed method is based on the Fourier expansion of the multipactor current in terms of time-harmonic currents radiating in the parallel-plate region. Classical radiation theory combined with the frequency domain Green's function of the problem allows the calculation of both the electric and the magnetic radiated fields. A novel analytical formula for the total radiated power of each multipactor harmonic has been derived. This formula is suitable for predicting multipactor with the third-harmonic technique. The proposed formulation has been successfu…
Two hybrid organometallic-inorganic layered magnets from the series [ ZIIICp*2] [ MIIMIII(ox)3] studied with μ+SR
2004
We present zero-field muon spin relaxation (ZF-μ + SR) measurements on two examples of a new series of hybrid organometallic-inorganic layered magnets, namely ferromagnetic [FeCp* 2 ][MnCr(ox) 3 ] and ferrimagnetic [CoCp* 2 ][FeFe(ox) 3 ] (where ox = oxalate and Cp* = pentame- thyl-cyclopentadienyl). Both materials show multi-component muon spin precession signals characteristic of quasistatic magnetic fields at several distinct muon sites. The temperature dependence of the precession frequencies allow critical exponents to be extracted. Possible muon sites are discussed on the basis of dipole field calculations.
Non-Local Transport in a Multi-Wall Carbon Nanotube
2001
Non-local electric transport phenomena were observed for a multi-wall carbon nanotube. The magnetic field dependence of non-local resistance was out of phase with respect to the conventional four-probe resistance, which could be explained in terms of the Landauer-Buttiker formula. Our observations indicate that the phase coherence length of multi-wall carbon nanotube exceeds the voltage probe length of about 1.1 µm at the measured temperatures.
Three-dimensional Hall effect accelerometer for recording head movements of freely moving laboratory animals
1991
A Hall effect device was constructed for a measurement of head movements in three spatial dimensions during classical conditioning experiments in cats. A Hall sensor was used to detect movements of a magnetic fragment floating in a small (15 x 15 mm) cube. The magnetic fragment was kept in the centre of the sealed cube with a thin coil spring which was filled with thin oil for damping excessive afteroscillations. A comparison of this device to a commercial accelerometer showed that the accuracy of the Hall device is sufficient for the movement recordings and that the device is sensitive also to slowly accelerating movements. The construction is compact and can be easily mounted, for example…