Search results for "MAS"

showing 10 items of 18047 documents

Modelling of expected B, C, N and O Lyman-α line intensities emitted from W7-X plasmas and measured by means of the W7-X light impurity monitor system

2021

AbstractThe “C/O Monitor” for Wendelstein 7-X (W7-X) is a dedicated light impurity XUV spectrometer intended to measure Lyman-α transitions of hydrogen-like ions of four low-Z impurities—boron (4.9 nm), carbon (3.4 nm), nitrogen (2.5 nm) and oxygen (1.9 nm). Since the discussed diagnostic will deliver continuous information about the line intensities, it is crucial to understand the origin of the obtained signals with respect to the experimental plasma conditions (electron temperature and density). This, however, might be difficult because of the broad acceptance angle of the spectrometer and irregular shape of the plasma edge or SOL where the radiation is expected to mostly come from, depe…

010302 applied physicsElectron densityMaterials scienceSpectrometerGeneral Physics and AstronomyPlasma01 natural sciences010305 fluids & plasmasIonRadiant fluxImpurityExtreme ultraviolet0103 physical sciencesElectron temperatureAtomic physics
researchProduct

High-Power Multicarrier Generation for RF Breakdown Testing

2017

Testing of satellite components for high RF power breakdown effects, such as multipactor and corona or passive-intermodulation, is a topic of growing interest in the aerospaceindustry. Switching fromthe classical single carrier approach to the more realisticmulticarrier scenario is very challenging from the experimental point of view. Themulticarrier signals, amplifiedby several RF power amplifiers, need to have controlled phase, amplitude, and frequency in each carrier. Fine tuning of the signal generator phases is required in order to compensate the phase drift occurring in the active elements of the test bed. This paper presents an efficient and low-cost technique to generate multicarrie…

010302 applied physicsEngineeringFine-tuningSignal generatorHigh-power RF testingMulticarrierbusiness.industryAmplifierRF power amplifierPhase (waves)Electrical engineering01 natural sciences010305 fluids & plasmasElectronic Optical and Magnetic MaterialsPower (physics)AmplitudeTEORIA DE LA SEÑAL Y COMUNICACIONES0103 physical sciencesSignal generationElectronic engineeringVacuum breakdownPoint (geometry)Electrical and Electronic EngineeringbusinessIEEE Transactions on Electron Devices
researchProduct

High-frequency electrodeless lamps in argon–mercury mixtures

2005

In this paper, numerical and experimental investigations of high-frequency (HF) electrodeless lamps in argon–mercury mixtures are performed. The intensities of the mercury spectral lines having wavelengths λ = 404.66, 435.83, 546.07 nm (7 3S1–6 3P0,1,2) and the resonance line λ = 253.7 nm (6 3 P1–6 1S0) are measured at a wide range of mercury pressures, varying the HF generator current and argon filling pressure. A stationary self-consistent model of HF electrodeless discharge lamp is developed including kinetics of the excited mercury and argon atomic states. Based on the developed model, the radiation characteristics of the discharge plasma are calculated. Numerical simulation of the line…

010302 applied physicsGas-discharge lampArgonAcoustics and Ultrasonics[SPI.PLASMA]Engineering Sciences [physics]/PlasmasAnalytical chemistrychemistry.chemical_elementPlasmaRadiationCondensed Matter Physics01 natural sciencesSpectral lineSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialslaw.inventionMercury (element)010309 opticsWavelengthchemistrylawExcited state0103 physical sciences[SPI.OPTI]Engineering Sciences [physics]/Optics / PhotonicComputingMilieux_MISCELLANEOUS
researchProduct

First experiments on applying the gasdynamic ECR ion source for negative hydrogen ion production

2017

This article has no abstract. peerReviewed

010302 applied physicsHydrogen ionta114ChemistryPhysicsQC1-99901 natural sciencesIon source010305 fluids & plasmasECR ion sourcesChemical physics0103 physical sciencesAtomic physicshydrogen ionsEPJ Web of Conferences
researchProduct

Injected 1+ ion beam as a diagnostics tool of charge breeder ECR ion source plasmas

2015

International audience; Charge breeder electron cyclotron resonance ion sources (CB-ECRIS) are used as 1+  →n+  charge multiplication devices of post-accelerated radioactive ion beams. The charge breeding process involves thermalization of the injected 1+  ions with the plasma ions in ion–ion collisions, subsequent ionization by electron impact and extraction of the n+  ions. Charge breeding experiments of 85Rb and 133Cs ion beams with the 14.5 GHz PHOENIX CB-ECRIS operating with oxygen gas demonstrate the plasma diagnostics capabilities of the 1+  injection method. Two populations can be distinguished in the m/q-spectrum of the extracted ion beams, the low (1+  and 2+) charge states repres…

010302 applied physicsIon beamAmbipolar diffusionChemistry[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]ElectronPlasmaCondensed Matter Physics01 natural sciences7. Clean energyIon source010305 fluids & plasmasIonPhysics::Plasma PhysicsIonization0103 physical sciencesAtomic physicsElectron ionization
researchProduct

A quartz amplifier for high-sensitivity Fourier-transform ion-cyclotron-resonance measurements with trapped ions

2019

Single-ion sensitivity is obtained in precision Penning-trap experiments devoted to light (anti)particles or ions with low mass-to-charge ratios, by adding an inductance coil to an amplifier connected to the trap, both operated at 4 K. However, single-ion sensitivity has not been reached on heavy singly or doubly charged ions. In this publication, we present a new system to reach this point, based on the use of a quartz crystal as an inductance, together with a newly developed broad-band (BB) amplifier. We detect the reduced-cyclotron frequency of 40Ca+ ions stored in a 7-tesla open-ring Penning trap. By comparing the detected electric signal obtained with the BB amplifier and the fluoresce…

010302 applied physicsMaterials scienceEquivalent series resistanceAmplifierPenning trap01 natural sciences7. Clean energySignalFourier transform ion cyclotron resonance010305 fluids & plasmasIonCrystal0103 physical sciencesAtomic physicsInstrumentationSensitivity (electronics)Review of Scientific Instruments
researchProduct

Photoelectron Emission from Metal Surfaces Induced by VUV-emission of Filament Driven Hydrogen Arc Discharge Plasma

2015

Photoelectron emission measurements have been performed using a filament-driven multi-cusp arc discharge volume production H^- ion source (LIISA). It has been found that photoelectron currents obtained with Al, Cu, Mo, Ta and stainless steel (SAE 304) are on the same order of magnitude. The photoelectron currents depend linearly on the discharge power. It is shown experimentally that photoelectron emission is significant only in the short wavelength range of hydrogen spectrum due to the energy dependence of the quantum efficiency. It is estimated from the measured data that the maximum photoelectron flux from plasma chamber walls is on the order of 1 A per kW of discharge power.

010302 applied physicsMaterials scienceHydrogenPhysics::Instrumentation and DetectorsFluxchemistry.chemical_elementFOS: Physical sciencesPlasma01 natural sciences7. Clean energyPhysics - Plasma PhysicsIon source010305 fluids & plasmasElectric arcPlasma Physics (physics.plasm-ph)chemistryPhysics::Plasma Physics0103 physical sciencesPhysics::Atomic and Molecular ClustersQuantum efficiencyPhysics::Atomic PhysicsAtomic physicsHydrogen spectral seriesOrder of magnitude
researchProduct

Operating a cesium sputter source in a pulsed mode

2020

A scheme is presented for pulsing of a cesium sputter negative ion source by periodically switching on and off the high voltage driving the sputtering process. We demonstrate how the pulsed ion beam can be used in combination with a pulsed laser (6 ns pulse length) that has a 10 Hz repetition rate to study the photodetachment process, where a negative ion is neutralized due to the absorption of a photon. In such experiments, where the ion beam is used only for a small fraction of the time, we show that the pulsed mode operation can increase the lifetime of a cathode by two orders of magnitude as compared with DC operation. We also investigate how the peak ion current compares with the ion c…

010302 applied physicsMaterials scienceIon beamPulse durationIon currentHigh voltage01 natural sciencesCathode010305 fluids & plasmasIonlaw.inventionPhysics::Plasma PhysicsSputteringlaw0103 physical sciencesAtomic physicsAbsorption (electromagnetic radiation)InstrumentationReview of Scientific Instruments
researchProduct

A new 18 GHz room temperature electron cyclotron resonance ion source for highly charged ion beams

2020

An innovative 18 GHz HIISI (Heavy Ion Ion Source Injector) room temperature Electron Cyclotron Resonance (ECR) ion source (ECRIS) has been designed and constructed at the Department of Physics, University of Jyväskylä (JYFL), for the nuclear physics program of the JYFL Accelerator Laboratory. The primary objective of HIISI is to increase the intensities of medium charge states (M/Q ≅ 5) by a factor of 10 in comparison with the JYFL 14 GHz ECRIS and to increase the maximum usable xenon charge state from 35+ to 44+ to serve the space electronics irradiation testing program. HIISI is equipped with a refrigerated permanent magnet hexapole and a noncylindrical plasma chamber to achieve very stro…

010302 applied physicsMaterials scienceIon beamsyklotronittutkimuslaitteetHighly charged ionchemistry.chemical_elementhiukkaskiihdyttimet01 natural sciences7. Clean energyIon sourceElectron cyclotron resonance010305 fluids & plasmasIonXenonchemistry0103 physical sciencesIrradiationAtomic physicsInstrumentationBeam (structure)
researchProduct

The effect of plasma instabilities on the background impurities in charge breeder ECRIS

2017

International audience; Experimental observations of plasma instabilities in the 14.5 GHz PHOENIX charge breeder ECRIS are summarized. It has been found that the injection of 133Cs+ or 85Rb+ into oxygen discharge of the CB-ECRIS can trigger electron cyclotron instabilities, which results to sputtering of the surfaces exposed to the plasma, followed by up to an order of magnitude increase of impurity currents in the extracted n+ charge state distribution. The transition from stable to unstable plasma regime is caused by gradual accumulation and ionization of Cs/Rb altering the discharge parameters in 10 - 100 ms time scale, not by a prompt interaction between the incident ion beam and the EC…

010302 applied physicsMaterials scienceIon beamta114syklotronit[PHYS.PHYS.PHYS-ACC-PH]Physics [physics]/Physics [physics]/Accelerator Physics [physics.acc-ph]Buffer gasCyclotronPlasmaElectroncharge breederplasmafysiikka7. Clean energy01 natural sciences010305 fluids & plasmaslaw.inventionIonECRISSputteringlawIonization0103 physical sciencesAtomic physicsplasma (kaasut)plasma
researchProduct