Search results for "MASS SPECTROMETRY"

showing 10 items of 2544 documents

Effect of simulated gastrointestinal digestion on plant sterols and their oxides in enriched beverages

2013

Abstract This study evaluates the bioaccessibility (percentage of soluble compound available for absorption) of plant sterols (PS) and their oxides (phytosterol oxidation products, POPs) after simulated gastrointestinal digestion in fruit (Fb), milk (M) and fruit-based milk beverages with (FbM a ) or without (FbM b ) tangerine juice. In beverages and their bioaccessible fraction (BF), campesterol, campestanol, stigmasterol, β-sitosterol and sitostanol were detected. Bioaccessibility of total PS ranged between 2.62 and 6.48%, FbM b yielding the highest value, followed by FbM a  > Fb > M. Campesterol/campestanol were the most bioaccessible PS. Only oxides of β-sitosterol were detected in beve…

Absorption (pharmacology)StigmasterolChromatographyCampesterolPhytosterolBEVERAGESCampestanolPLANT STEROLchemistry.chemical_compoundchemistryPLANT STEROL; SIMULATED GASTROINTESTINAL DIGESTION; STEROL OXIDATION PRODUCTS; BEVERAGESFood scienceGas chromatography–mass spectrometrySolubilitySIMULATED GASTROINTESTINAL DIGESTIONPlant sterolsSTEROL OXIDATION PRODUCTSFood Science
researchProduct

Regioselective Hydrogenation of a 60-Carbon Nanographene Molecule toward a Circumbiphenyl Core.

2019

Regioselective peripheral hydrogenation of a nanographene molecule with 60 contiguous sp2 carbons provides unprecedented access to peralkylated circumbiphenyl (1). Conversion to the circumbiphenyl core structure was unambiguously validated by MALDI-TOF mass spectrometry, NMR, FT-IR, and Raman spectroscopy. UV–vis absorption spectra and DFT calculations demonstrated the significant change of the optoelectronic properties upon peripheral hydrogenation. Stimulated emission from 1, observed via ultrafast transient absorption measurements, indicates potential as an optical gain material.

Absorption spectroscopyChemistryCommunicationChemistry (all)RegioselectivityGeneral Chemistry010402 general chemistryMass spectrometryPhotochemistryCatalysis; Chemistry (all); Biochemistry; Colloid and Surface Chemistry01 natural sciencesBiochemistryCatalysis0104 chemical sciencesCatalysissymbols.namesakeColloid and Surface ChemistryUltrafast laser spectroscopysymbolsMoleculeStimulated emissionRaman spectroscopyJournal of the American Chemical Society
researchProduct

Ag11(SG)7 : A New Cluster Identified by Mass Spectrometry and Optical Spectroscopy

2014

We report a one-step and high yield synthesis of a red-luminescent silver cluster with the molecular formula, Ag11(SG)7 (SG: glutathionate) via reduction of silver ions by sodium borohydride in the presence of the tripeptide, glutathione (GSH). The as-prepared cluster shows prominent absorption features at 485 and 625 nm in its UV-vis absorption spectrum. Aging of the as-prepared cluster solution led to the disappearance of the 625 nm peak, followed by broadening of the 485 nm peak to give three maxima at ?487, 437, and 393 nm in its absorption spectrum. These peaks remain unchanged even after polyacrylamide gel electrophoresis (PAGE), where a single band was observed confirming high purity…

Absorption spectroscopyta114Electrospray ionizationAnalytical chemistryMass spectrometryAbsorption spectra; Density functional theory; Electrodeposition; Electromagnetic wave absorption; Electrophoresis; Electrospray ionization; Isotopes; Light absorption; Mass spectrometry; Metal ions; Potable water; Spectrometry; Ultraviolet spectroscopy; Absorption features; Electrospray ionization mass spectrometry; High yield synthesis; Molecular formula; Optical spectroscopy; Polyacrylamide gel electrophoresis; Sodium boro hydrides; UV-VIS absorption spectra; Absorption spectroscopySurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsIonSodium borohydridechemistry.chemical_compoundGeneral EnergyUltraviolet visible spectroscopychemistryPhysical and Theoretical ChemistryAbsorption (electromagnetic radiation)Spectroscopyta116Journal of Physical Chemistry C
researchProduct

Comparison of novel and conventional calibration techniques for the analysis of urine samples using plasma source mass spectrometry combined with a n…

2012

The accuracy and precision of the analytical data from the analysis of liquid samples with high matrix load often suffer from a compromised performance of the sample introduction system. This is especially significant in the case of miniaturized, pneumatic low flow nebulizers. Alternative low-flow sampling devices based on different operating principles are imperative to overcome this drawback. The superior performance of such an alternative liquid sample introduction system for ICP-MS, the drop-on-demand (DOD) aerosol generator based on thermal inkjet technology, was recently outlined by the same group for the analysis of aqueous standard solutions. Current improvements of the system now a…

Accuracy and precisionChemistrybusiness.industryPlasma source mass spectrometryDrop (liquid)NozzleAnalytical chemistryStandard solutionAnalytical ChemistryMatrix (chemical analysis)Aerosol generatorOn demandProcess engineeringbusinessSpectroscopyJournal of Analytical Atomic Spectrometry
researchProduct

Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM…

2000

The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, hav…

Accuracy and precisionGeneral Chemical EngineeringAnalytical chemistrychemistry.chemical_elementGeneral ChemistryIsotope dilutionPolyethyleneMass spectrometryMatrix (chemical analysis)Chromiumchemistry.chemical_compoundThird phasechemistrySafety Risk Reliability and QualityInstrumentationInductively coupled plasma mass spectrometryAccreditation and Quality Assurance
researchProduct

Development of microextraction techniques in combination with GC-MS/MS for the determination of mycotoxins and metabolites in human urine.

2017

Simple and highly efficient sample preparation procedures, namely, dispersive liquid–liquid microextraction and salting-out liquid–liquid extraction for the analysis of ten Fusarium mycotoxins and metabolites in human urine were compared. Various parameters affecting extraction efficiency were carefully evaluated. Under optimal extraction conditions, salting-out liquid–liquid extraction showed a better accuracy (84–96%) and precision (<14%) than dispersive liquid–liquid microextraction. Hence, a multibiomarker method based on salting-out liquid–liquid extraction followed by gas chromatography with tandem mass spectrometry was proposed. Satisfactory results in terms of validation were achiev…

Accuracy and precisionLiquid Phase MicroextractionFiltration and SeparationPilot ProjectsUrineUrinalysisTandem mass spectrometry01 natural sciencesGas Chromatography-Mass SpectrometryAnalytical Chemistry0404 agricultural biotechnologyLimit of DetectionTandem Mass SpectrometryHumansSample preparationDetection limitChromatographyChemistry010401 analytical chemistryExtraction (chemistry)04 agricultural and veterinary sciencesMycotoxins040401 food science0104 chemical sciencesGas chromatographyGas chromatography–mass spectrometryJournal of separation science
researchProduct

230Th/U-dating of a late Holocene low uranium speleothem from Cuba

2010

We present 22 U-series ages for a stalagmite from north-western Cuba based on multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) and thermal ionisation mass spectrometry (TIMS). Our results reveal that the stalagmite continuously grew within the last ~1400a. Low uranium content of the sample and thus, extremely low 230Th concentrations limit the precision and accuracy of 230Th/U-dating by TIMS. Samples measured by MC-ICPMS show a high variability of 232Th content along the growth axis with some sections significantly affected by initial 230Th from a detrital phase. An a-priori bulk earth ratio for (238U/232Th) cannot be used to accurately account for this initial 230Th.…

Accuracy and precisiongeographygeography.geographical_feature_categoryMineralogyThermal ionizationSpeleothemchemistry.chemical_elementStalagmiteUraniumMass spectrometrychemistryInductively coupled plasma mass spectrometryGeologyHoloceneIOP Conference Series: Earth and Environmental Science
researchProduct

Quantitative evaluation of the phenolic profile in fruits of six avocado (Persea americana) cultivars by ultra-high-performance liquid chromatography…

2016

The phenolic profiles of six varieties of avocado (Persea americana) grown in Sicily were investigated. The ultra-high-performance liquid chromatography-heated electrospray-mass spectrometry method was developed to determine qualitative and quantitative changes in fruits at two different ripening stage. Nineteen individual phenolic compounds were detected in avocado pulp extracts. Gallic acid, sinapinic acid, vanillin, p-coumaric acid, and gentisic acid were present only in ripe fruits. On the contrary, epicatechin decreased with fruit ripening, whereas protocatechuic acid, 4-hydroxybenzoic acid, chlorogenic acid, and benzoic acid were relatively stable or exhibited erratic changes with fru…

Accurate mass; Fruit ripening; High-resolution mass spectrometry; LDA; Persea americana; Phenolic compounds; Ultra-high-performance liquid chromatography; Food SciencePerseaHigh-resolution mass spectrometrySettore CHIM/10 - Chimica Degli AlimentiLDAPhenolic compoundSinapinic acid01 natural sciencesProtocatechuic acidchemistry.chemical_compound0404 agricultural biotechnologyChlorogenic acidBotanySettore CHIM/01 - Chimica AnaliticaGallic acidFood scienceGentisic acidAccurate mabiologyVanillin010401 analytical chemistryfood and beveragesRipening04 agricultural and veterinary sciencesbiology.organism_classificationFruit ripening040401 food scienceSettore CHIM/08 - Chimica Farmaceutica0104 chemical sciencesSettore AGR/03 - Arboricoltura Generale E Coltivazioni ArboreechemistryPersea americanaUltra-high-performance liquid chromatographyPhenolic compounds; Persea americana; Accurate mass; Ultra-high-performance liquid chromatography; High-resolution mass spectrometry; LDA; Fruit ripeningFood Science
researchProduct

Investigation of the Electrophoretic Mobility of the Actinides Th, U, Np, Pu, and Am in Different Oxidation States.

2019

The electrophoretic mobilities (μe) of the actinides Th and U-Am in different oxidation states (prepared in 1 M HCl and 1 M HClO4) have been determined by capillary electrophoresis (CE)-inductively coupled plasma mass spectrometry (ICPMS) using 1 M acetic acid as the background electrolyte, which has proven to provide an excellent setup for trace analysis at environmentally relevant concentrations (1 × 10-9 M). The values are independent of the respective acid solution. The μe of the Pu oxidation states +III to +VI have been measured. They agree with both the available literature data and the redox-stable analogues (Eu(III), Th(IV), Np(V), U(VI)) that have also been investigated. The trend …

Acetic acidchemistry.chemical_compoundElectrophoresisCapillary electrophoresischemistryAnalytical chemistryTrace analysisElectrophoretic mobilitiesElectrolyteActinideMass spectrometryAnalytical ChemistryAnalytical chemistry
researchProduct

Development of a GC–MS/MS strategy to determine 15 mycotoxins and metabolites in human urine

2014

The widespread mycotoxins contamination of food commodities has made the monitoring of their levels essential. To overcome the disadvantages of the indirect approach by food analysis, detection of mycotoxin as biomarkers in urine provides a useful and specific data for exposure assessment to these food contaminants. In this work, a sensitive, rapid and accurate method based on gas chromatography-tandem mass spectrometry procedure to determine 15 mycotoxins and metabolites in human urine was optimized and validated taking into consideration the guidelines specified in Commission Decision 2002/657/EC and 401/2006/EC. A salting-out assisted acetonitrile-based extraction was used for sample pre…

AcetonitrilesChromatographyChemistryExtraction (chemistry)Reproducibility of ResultsFood ContaminationGuidelines as TopicUrineMycotoxinsContaminationGas Chromatography-Mass SpectrometryFood AnalysisAnalytical Chemistrychemistry.chemical_compoundReference ValuesTandem Mass SpectrometryCalibrationHumansSample preparationGas chromatography–mass spectrometryChildMycotoxinBiomarkersFood contaminantTalanta
researchProduct