Search results for "MASS SPECTROMETRY"
showing 10 items of 2544 documents
Effect of simulated gastrointestinal digestion on plant sterols and their oxides in enriched beverages
2013
Abstract This study evaluates the bioaccessibility (percentage of soluble compound available for absorption) of plant sterols (PS) and their oxides (phytosterol oxidation products, POPs) after simulated gastrointestinal digestion in fruit (Fb), milk (M) and fruit-based milk beverages with (FbM a ) or without (FbM b ) tangerine juice. In beverages and their bioaccessible fraction (BF), campesterol, campestanol, stigmasterol, β-sitosterol and sitostanol were detected. Bioaccessibility of total PS ranged between 2.62 and 6.48%, FbM b yielding the highest value, followed by FbM a > Fb > M. Campesterol/campestanol were the most bioaccessible PS. Only oxides of β-sitosterol were detected in beve…
Regioselective Hydrogenation of a 60-Carbon Nanographene Molecule toward a Circumbiphenyl Core.
2019
Regioselective peripheral hydrogenation of a nanographene molecule with 60 contiguous sp2 carbons provides unprecedented access to peralkylated circumbiphenyl (1). Conversion to the circumbiphenyl core structure was unambiguously validated by MALDI-TOF mass spectrometry, NMR, FT-IR, and Raman spectroscopy. UV–vis absorption spectra and DFT calculations demonstrated the significant change of the optoelectronic properties upon peripheral hydrogenation. Stimulated emission from 1, observed via ultrafast transient absorption measurements, indicates potential as an optical gain material.
Ag11(SG)7 : A New Cluster Identified by Mass Spectrometry and Optical Spectroscopy
2014
We report a one-step and high yield synthesis of a red-luminescent silver cluster with the molecular formula, Ag11(SG)7 (SG: glutathionate) via reduction of silver ions by sodium borohydride in the presence of the tripeptide, glutathione (GSH). The as-prepared cluster shows prominent absorption features at 485 and 625 nm in its UV-vis absorption spectrum. Aging of the as-prepared cluster solution led to the disappearance of the 625 nm peak, followed by broadening of the 485 nm peak to give three maxima at ?487, 437, and 393 nm in its absorption spectrum. These peaks remain unchanged even after polyacrylamide gel electrophoresis (PAGE), where a single band was observed confirming high purity…
Comparison of novel and conventional calibration techniques for the analysis of urine samples using plasma source mass spectrometry combined with a n…
2012
The accuracy and precision of the analytical data from the analysis of liquid samples with high matrix load often suffer from a compromised performance of the sample introduction system. This is especially significant in the case of miniaturized, pneumatic low flow nebulizers. Alternative low-flow sampling devices based on different operating principles are imperative to overcome this drawback. The superior performance of such an alternative liquid sample introduction system for ICP-MS, the drop-on-demand (DOD) aerosol generator based on thermal inkjet technology, was recently outlined by the same group for the analysis of aqueous standard solutions. Current improvements of the system now a…
Producing SI-traceable reference values for Cd, Cr and Pb amount contents in polyethylene samples from the Polymer Elemental Reference Material (PERM…
2000
The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, hav…
Development of microextraction techniques in combination with GC-MS/MS for the determination of mycotoxins and metabolites in human urine.
2017
Simple and highly efficient sample preparation procedures, namely, dispersive liquid–liquid microextraction and salting-out liquid–liquid extraction for the analysis of ten Fusarium mycotoxins and metabolites in human urine were compared. Various parameters affecting extraction efficiency were carefully evaluated. Under optimal extraction conditions, salting-out liquid–liquid extraction showed a better accuracy (84–96%) and precision (<14%) than dispersive liquid–liquid microextraction. Hence, a multibiomarker method based on salting-out liquid–liquid extraction followed by gas chromatography with tandem mass spectrometry was proposed. Satisfactory results in terms of validation were achiev…
230Th/U-dating of a late Holocene low uranium speleothem from Cuba
2010
We present 22 U-series ages for a stalagmite from north-western Cuba based on multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) and thermal ionisation mass spectrometry (TIMS). Our results reveal that the stalagmite continuously grew within the last ~1400a. Low uranium content of the sample and thus, extremely low 230Th concentrations limit the precision and accuracy of 230Th/U-dating by TIMS. Samples measured by MC-ICPMS show a high variability of 232Th content along the growth axis with some sections significantly affected by initial 230Th from a detrital phase. An a-priori bulk earth ratio for (238U/232Th) cannot be used to accurately account for this initial 230Th.…
Quantitative evaluation of the phenolic profile in fruits of six avocado (Persea americana) cultivars by ultra-high-performance liquid chromatography…
2016
The phenolic profiles of six varieties of avocado (Persea americana) grown in Sicily were investigated. The ultra-high-performance liquid chromatography-heated electrospray-mass spectrometry method was developed to determine qualitative and quantitative changes in fruits at two different ripening stage. Nineteen individual phenolic compounds were detected in avocado pulp extracts. Gallic acid, sinapinic acid, vanillin, p-coumaric acid, and gentisic acid were present only in ripe fruits. On the contrary, epicatechin decreased with fruit ripening, whereas protocatechuic acid, 4-hydroxybenzoic acid, chlorogenic acid, and benzoic acid were relatively stable or exhibited erratic changes with fru…
Investigation of the Electrophoretic Mobility of the Actinides Th, U, Np, Pu, and Am in Different Oxidation States.
2019
The electrophoretic mobilities (μe) of the actinides Th and U-Am in different oxidation states (prepared in 1 M HCl and 1 M HClO4) have been determined by capillary electrophoresis (CE)-inductively coupled plasma mass spectrometry (ICPMS) using 1 M acetic acid as the background electrolyte, which has proven to provide an excellent setup for trace analysis at environmentally relevant concentrations (1 × 10-9 M). The values are independent of the respective acid solution. The μe of the Pu oxidation states +III to +VI have been measured. They agree with both the available literature data and the redox-stable analogues (Eu(III), Th(IV), Np(V), U(VI)) that have also been investigated. The trend …
Development of a GC–MS/MS strategy to determine 15 mycotoxins and metabolites in human urine
2014
The widespread mycotoxins contamination of food commodities has made the monitoring of their levels essential. To overcome the disadvantages of the indirect approach by food analysis, detection of mycotoxin as biomarkers in urine provides a useful and specific data for exposure assessment to these food contaminants. In this work, a sensitive, rapid and accurate method based on gas chromatography-tandem mass spectrometry procedure to determine 15 mycotoxins and metabolites in human urine was optimized and validated taking into consideration the guidelines specified in Commission Decision 2002/657/EC and 401/2006/EC. A salting-out assisted acetonitrile-based extraction was used for sample pre…