Search results for "MEAT"
showing 10 items of 515 documents
Separation Efficiency of Two SEC Packings: Comparison of Chromatographic, Thermodynamic, and Fractal Parameters
2004
Abstract The size‐exclusion chromatographic (SEC), thermodynamic, and fractal behavior of two organic packings, named TSK‐Gel HHR and TSK‐Gel HXL, has been compared in order to assess their separation efficiency. The different experimental elution trends of five solvent/polymer systems have been evidenced through the universal calibration curves, and the existence of secondary mechanisms (such as adsorption) has been quantified by the chromatographic partition coefficient K p. From a thermodynamic point of view, the swelling and crosslinking degrees have been evaluated and compared in the two gels assayed. Moreover, the values of some fractal parameters (fractal dimension of the surface and…
Gel permeation Chromatography in coiled columns
1973
Whereas in gas chromatography the use of coiled columns is the usual procedure, in liquid chromatography the use of straight columns is favoured. Bent columns give an additional contribution to peak spreading which is of greater importance in liquid chromatography than in gas chromatography owing to smaller diffusion coefficients. The low linear velocities of the mobile phase used in gel permeation chromatography enable conditions to be found where the additional contribution of bending to peak spreading is small. In the separation of oligomers, columns of 2-mm tube diameter and 20-cm coil diameter were used. With total lengths of 10 and 20 m, theoretical plate counts of ca. 70,000 and 150,…
Size Exclusion Chromatography for Semipreparative Scale Separation of Au 38 (SR) 24 and Au 40 (SR) 24 and Larger Clusters
2011
Size exclusion chromatography (SEC) on a semipreparative scale (10 mg and more) was used to size-select ultrasmall gold nanoclusters (2 nm) from polydisperse mixtures. In particular, the ubiquitous byproducts of the etching process toward Au(38)(SR)(24) (SR, thiolate) clusters were separated and gained in high monodispersity (based on mass spectrometry). The isolated fractions were characterized by UV-vis spectroscopy, MALDI mass spectrometry, HPLC, and electron microscopy. Most notably, the separation of Au(38)(SR)(24) and Au(40)(SR)(24) clusters is demonstrated.
Accurate determination of element species by on-line coupling of chromatographic systems with ICP-MS using isotope dilution technique
1998
Abstract The instrumental design for coupling different liquid chromatographic systems such as ion, reversed phase, and size exclusion chromatography as well as capillary gas chromatography, with ICP-MS for the determination of element species is described. For accurate analyses obtaining ‘real time’ concentrations of chromatographic peaks, the isotope dilution mass spectrometric (IDMS) technique is applied. Two different spiking modes are possible, one using species-specific and another one using species-unspecific spike solutions of isotope-enriched labelled compounds. The species-specific mode is only possible for element species well defined in their structure and composition, for examp…
Spray Freeze Dried Lyospheres® for Nasal Administration of Insulin
2021
Pharmacologically active macromolecules, such as peptides, are still a major challenge in terms of designing a delivery system for their transport across absorption barriers and at the same time provide sufficiently high long-term stability. Spray freeze dried (SFD) lyospheres® are proposed here as an alternative for the preparation of fast dissolving porous particles for nasal administration of insulin. Insulin solutions containing mannitol and polyvinylpyrrolidone complemented with permeation enhancing excipients (sodium taurocholate or cyclodextrins) were sprayed into a cooled spray tower, followed by vacuum freeze drying. Final porous particles were highly spherical and mean diameters r…
Estimation of the Compatibility Between Poly(Methylmethacrylate) and Poly(Styrene Co Vinyl Phenol) Blends from Dilute Solution Measurements
2006
Abstract The compatibility of poly(methyl methacrylate) (PMMA) with poly(styrene‐co‐vinyl phenol) (PS‐VPh) with two different contents of vinyl phenol, 5.8 and 7.2%, in dilute tetrahydrofuran solutions has been investigated by size exclusion chromatography and fluorescence spectroscopy at 25°C. The chromatographic technique permits the evaluation of the preferential solvation at different PMMA/PS‐VPh ratios. Changes in the fluorescence properties of PS‐VPh, caused by its association with PMMA, were used to obtain the fraction of copolymer bound to PMMA at diverse PMMA compositions. Both techniques agree quantitatively in every system, indicating that the association increases when the PMMA …
In Vitro and In Silico Studies of Two 1,4-Naphthoquinones and Their Topical Formulation in Bigels.
2021
Background: 1,4-Naphthoquinones (1,4-NQs) are secondary plant metabolites with numerous biological activities. 1,4-NQs display low water solubility and poor bioavailability. Bigels are a new technology with great potential, which are designated as drug delivery systems. Biphasic bigels consisting of solid and liquid components represent suitable formulations improving diffusion and bioavailability of NQs into the skin. Objective: We evaluated the in silico and in vitro activity of 5,8-dihydroxy-1,4-naphthoquinone (M1) and 2,3-dichloro-5,8-dihydroxy-1,4-naphthoquinone (M2) on elastase and assessed their cytotoxicity towards COLO38 melanoma cells. The 1,4-NQs were loaded into bigels for topi…
Sulphonic acid strong cation-exchange restricted access columns in sample cleanup for profiling of endogeneous peptides in multidimensional liquid ch…
2006
Abstract In this work, the pore structural parameters and size exclusion properties of LiChrospher strong cation-exchange and reverse phase restricted access materials (RAM) are analysed. The molecular weight size exclusion limit for polystyrenes was found to be about 17.7 kDa, while for standard proteins, the molecular weight size exclusion limit was higher, at approximately 25 kDa. The average pore diameter on a volume basis calculated from the pore network model changes from 8.5 nm (native LiChrospher) to 8.6 nm (diol derivative) to 8.2 nm (sulphonic acid derivative) to 6.9 nm ( n -octadecyl derivative). Additional characterisations were performed on restricted access materials with nitr…
Study on a photocatalytic membrane reactor for water purification
2000
Abstract Some results obtained in a photocatalytic membrane reactor, to be used for degradation of toxic organic species dissolved in water, are reported. The catalyst, TiO 2 P25 Degussa, was immobilised by means of a flat sheet polymeric membrane and 4-Nitrophenol (4-NP) was used as a model molecule to evaluate the reactor performance. A preliminary investigation of the stability, under UV irradiation, of some eligible polymeric membranes was carried out by using scanning electron microscopy (SEM), optical microscopy (OM), determinations of water permeation flux (WPF) and total organic carbon (TOC). These tests showed that commercial membranes made of fluoride + PP (FS 50 PP-Dow), polysulp…
Influence of brine concentration on swelling pressure of pork meat throughout salting.
2009
Abstract The influence of sodium chloride on the water holding capacity of meat is well known and described in literature. An increase in water holding capacity is associated with an increase in the swelling pressure in the protein matrix. A novel device was used to measure the swelling pressure during brine salting of muscle cylinders (40 × 50 mm), in different NaCl brine concentrations (2.5 to 25%) over 6 days at 4 °C. Changes in meat composition, weight and height of non-constrained control samples were also measured. The aim of this work was to prove the feasibility of using the developed device in order to quantify the influence of the brine concentration on the magnitude of the swelli…