Search results for "MISURE"

showing 10 items of 496 documents

A study on the effect of contact pressure during physical activity on photoplethysmographic heart rate measurements

2020

Heart rate (HR) as an important physiological indicator could properly describe global subject&rsquo

Future studies0206 medical engineeringheart rate (HR)Physical activityPhysical exercise02 engineering and technologylcsh:Chemical technology01 natural sciencesBiochemistrySignalContact force Contact pressure Heart rate (HR) Heart rate reliability Heart rate signal Photoplethysmography (PPG) PPG accuracy PPG sensor WearablesArticleAnalytical ChemistryPPG accuracysymbols.namesakeWearable Electronic Devicesphotoplethysmography (PPG)Heart RateHeart rateSettore ING-IND/12 - Misure Meccaniche E TermicheMedicineheart rate reliabilityHumanslcsh:TP1-1185Electrical and Electronic EngineeringPhotoplethysmographyInstrumentationExercisecontact pressureheart rate signalbusiness.industry010401 analytical chemistrySignal Processing Computer-Assisted020601 biomedical engineeringAtomic and Molecular Physics and OpticsPearson product-moment correlation coefficient0104 chemical sciencesIntensity (physics)PPG sensorwearablessymbolssense organsbusinesscontact forceContact pressureBiomedical engineering
researchProduct

Equivalent detector models for the simulation of efficiency response of an HPGe detector with PENELOPE code

2019

Monte Carlo simulation of response of an HPGe detector is a widely used technique to evaluate counting efficiencies. It is particularly useful when calibration standards with the same shape and composition of the sample under examination are not available. The result of the simulation depends on the more or less detailed knowledge of the characteristics of the detector, able to define a "model" of the same detector. To highlight parts not well defined in the manufacturer's certification, a detector X-ray analysis is usually performed, except in cases when it is not possible to dismantle the shielding structure with the loss of previous calibration data. In this work, in absence of some data…

Gamma-ray spectrometry Monte Carlo HPGe detectors efficiency modelingSettore ING-IND/20 - Misure E Strumentazione Nucleari
researchProduct

PVA-GTA Fricke gel dosimeters exposed to clinical photons beams: Nuclear Magnetic Resonance Relaxometry and Imaging

2016

Fricke Gel (FXGs) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. The application of Fricke gels for ionizing radiation dosimetry is continuously increasing worldwide due to their many favorable properties. However, one of their shortcomings is that ferrous and ferric ions diffuse in the gel matrix. To maintain the spatial integrity of the dose distribution, Fricke gels must be undergoing measurement within a few hours of their irradiation, so that ferric ions remain close to their point of production. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained (Schreiner, 2015). The gel matrix also contributes to the oxidati…

Gel Dosimeters NMR MRI PVA GTA 3D DoseSettore ING-IND/20 - Misure E Strumentazione NucleariSettore FIS/01 - Fisica SperimentaleSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

A radiometric and petrographic interpretation of discrepancies on uranium content in samples collected at Alte Madonie Mounts region (Sicily, Italy)

2013

Abstract The main goal of this work is to evaluate a correlation between anomalous Uranium (U) content and petrographic features of some soil and rock samples collected at Alte Madonie Mounts region (North-central Sicily, Italy). A total of 41 samples of selected soils and rocks were collected, powdered, dried and sealed in “Marinelli” beakers for 20 days before the measurement to ensure that radioactive equilibrium between 226 Ra and 214 Bi was reached. Gamma-ray spectrometric analysis was used to quantify radioactivity concentrations. Mineralogical and chemical features of the samples were determined by X-ray Fluorescence (XRF), X-ray Diffractometry (XRD), Attenuated Total Reflection-Four…

Geological PhenomenaSettore ING-IND/20 - Misure E Strumentazione NucleariHealth Toxicology and MutagenesisAnalytical chemistryMineralogyX-ray fluorescencechemistry.chemical_elementPetrographyRadiation MonitoringSoil Pollutants RadioactiveEnvironmental ChemistryRadiometryWaste Management and DisposalGamma ray spectrometryRadioisotopesSettore GEO/07 - Petrologia E PetrografiaGeneral MedicineUraniumPollutionSpectrometry GammaItalychemistryEnvironmental radioactivity Radiation monitoring Gamma-ray spectrometry X-rayfluorescence X-ray diffractometryEnergy dispersive spectrometrySoil waterUraniumEnvironmental radioactivityEnvironmental scienceRadiometric datingBismuthJournal of Environmental Radioactivity
researchProduct

A procedure to evaluate coincidence-summing correction values in gamma-ray spectrometry with HPGe detectors

2009

The spectrometric analysis of a gamma-emitter sample measured in "close geometry" can be affected by errors due to coincidence-summing effects that can occur when two or more coincident photons (real coincidences) within the resolution time of the spectrometric system are emitted. The probability that these effects occur depends primarily on the nuclide decay scheme, the sample-detector distance and detector intrinsic-efficiency whereas results independent from the sample nuclide activity. Coincidence-summing corrections of the photopeak areas are requested, in particular, when the gamma ray spectrometric analysis is aimed to efficiency or activity determination. In this work is reported a …

HPge detectorsgamma-ray spectrometrySettore ING-IND/20 - Misure E Strumentazione Nuclearicoincidence-summing
researchProduct

Measurement issues on harmonic analysis according to the IEC 61000-4-7

2022

The objective of this article is an analysis of measurement issues related to the implementation of digital signal processing techniques for harmonic analysis, by means of FFT algorithm with different interpolation algorithms (linear, quadratic and cubic) and different sampling rates. A comparative analysis is made on errors on harmonics measurement obtained in the various case study analyses. Such errors are compared with the IEC 61000-4-7 limits. The study is supported by both simulation and experimental tests; these last are performed with different acquisition boards for signals acquisition.

Harmonic analysisIEC 61000-4-7power qualitypower system measurementsSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Indoor Fast Neutron Generator for Biophysical and Electronic Applications

2018

This study focuses the attention on an indoor fast neutron generator for biophysical and electronic applications. More specifically, the findings obtained by several simulations with the MCNP Monte Carlo code, necessary for the realization of a shield for indoor measurements, are presented. Furthermore, an evaluation of the neutron spectrum modification caused by the shielding is reported. Fast neutron generators are a valid and interesting available source of neutrons, increasingly employed in a wide range of research fields, such as science and engineering. The employed portable pulsed neutron source is a MP320 Thermo Scientific neutron generator, able to generate 2.5 MeV neutrons with a …

HistoryMaterials scienceNeutron generatorSettore ING-IND/20 - Misure E Strumentazione NucleariNuclear engineeringFast neutrons Generator Monte CarloComputer Science ApplicationsEducation
researchProduct

Un metodo single-point basato sulla IEEE 1459-2000 “effective apparent power resolution” per l’individuazione dei carichi disturbanti nei sistemi ele…

2009

IEEE 1459-2000 sistemi di potenza localizzazione delle sorgenti armonicheSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A single-point approach based on nonactive power factor for the assessment of harmonic distortion sources in power systems

2022

This paper presents a study on the use of power factor indicators for the assessment of harmonic distortion sources in power systems. In detail the analysis is focused on the comparison between the proposed nonactive power factor (Q1/N) and the indicators of the IEEE Std. 1459-2010, and on the indicators feasibility in identifying the presence of harmonic distortion sources. As discussed in the paper, the proposed indicator can be evaluated with good accuracy, by means of typical power quantities measurements at the point of common coupling (PCC). Thus its measurement can be feasibly implemented in commercial platforms used for smart metering applications. To verify the proposal validity, s…

IEEE 1459-2010Power QualityPower Ratio QuantitiesSettore ING-INF/07 - Misure Elettriche E Elettroniche2022 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
researchProduct

Conducibilità idraulica del suolo: Metodi di misura nelle applicazioni idrologiche

2010

Idrologia Misure Conducibilità idraulica del suoloSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-Forestali
researchProduct