Search results for "MISURE"

showing 10 items of 496 documents

Design of an open-lab activity for engineering students: A case study

2022

Project- or discovery-based learning activities promote curiosity, enjoyment, and interest deriving from the stimulating context in which students operate. Providing a concrete contextualization of laboratory activities could improve student motivation and learning outcomes. In this contribution, a case study related to a workshop on laboratory activities proposed for Engineering Master students is presented, and designed with the aim of developing practical competencies, increasing problem-solving skills, and providing design abilities. Using the facilities available in the Measurements and Control Laboratory, the students, starting from concept knowledge acquired in basic subjects, such …

Laboratory activitieSettore FIS/08 - Didattica E Storia Della FisicaMechanical EngineeringSettore ING-IND/12 - Misure Meccaniche E TermicheProblem-solving skillsProject-based learningSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)EducationInternational Journal of Mechanical Engineering Education
researchProduct

Assisted software design of a wide variety of windings in rotating electrical machinery

2014

In this paper a software developed by the Authors for winding design is presented. In particular, this software can be used as a valid aid in design and analysis for a wide variety of windings with generic number of phases, pole pairs, slot number, etc.. The calculation of winding factors and the evaluation of their harmonic distribution is also accomplished. The software is implemented in MATLAB® environment. By means of some examples, covering the most relevant winding types, the capabilities of this software will be shown. Particularly, integer and fractional slot, single and double layer winding, concentrated windings, imbrication, belt widening and belt shifting techniques can be treat…

Leakage inductanceEngineeringTotal harmonic distortionm.m.f.business.industryElectrical engineeringSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciwindingSoftwareharmonicMagnetomotive forceHarmonicsPhysics::Space Physicsflux densityWinding factorAstrophysics::Solar and Stellar AstrophysicsSoftware designwinding factorsdifferential leakagebusinessSettore ING-INF/07 - Misure Elettriche E ElettronichePhysics::Atmospheric and Oceanic PhysicsHarmonic distributionwinding connection
researchProduct

Maximum Torque per Ampere Control strategy for low-saliency ratio IPMSMs

2019

This paper deals with electrical drives employing low-saliency ratio interior permanent magnet synchronous motors. In particular, in order to help the designers choosing the best control algorithm, the performances of the Maximum Torque Per Ampere Control (MTPA) and the Field Orientation Control (FOC) are here both theoretically and experimentally assessed and compared, by using, as performance indicators, the torque-current ratio and the power losses. The tests are carried out on a low-power motor for various speeds and loads by implementing the two control strategies in a dSPACE® rapid prototyping system. The results show that the Maximum Torque Per Ampere algorithm has some appreciable a…

Low saliency ratio machineMTPA control strategySettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciFOC algorithmSettore ING-INF/07 - Misure Elettriche E ElettronicheIPMSM
researchProduct

IN TEMA DI MISURE CAUTELARI IN MATERIA FISCALE

2014

MISURE CAUTELARI FISCALISettore IUS/12 - Diritto Tributario
researchProduct

Modeling Right Ventricle Failure After Continuous Flow Left Ventricular Assist Device: A Biventricular Finite-Element and Lumped-Parameter Analysis

2017

The risk of right ventricle (RV) failure remains a major contraindication for continuous-flow left ventricular assist device (CF-LVAD) implantation in patients with heart failure. It is therefore critical to identify the patients who will benefit from early intervention to avoid adverse outcomes. We sought to advance the computational modeling description of the mechanisms underlying RV failure in LVAD-supported patients. RV failure was studied by computational modeling of hemodynamic and cardiac mechanics using lumped-parameter and biventricular finite element (FE) analysis. Findings were validated by comparison of bi-dimensional speckle-tracking echocardiographic strain assessment of the …

MaleCardiac CatheterizationCardiac outputVentricular Dysfunction Rightmedicine.medical_treatmentHemodynamicsSpeckle tracking echocardiography02 engineering and technology030204 cardiovascular system & hematologySeverity of Illness IndexRight ventricular failure Left ventricular assist device Speckle-tracking echocardiography Lumped-parameter Finite-element analysis.Ventricular Function LeftVentricular Dysfunction Left0302 clinical medicineRisk FactorsMedicineModels CardiovascularMiddle AgedTreatment Outcomemedicine.anatomical_structureEchocardiographyCardiologyFemaleCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyFinite Element Analysis0206 medical engineeringBiomedical EngineeringProsthesis DesignProsthesis Implantation03 medical and health sciencesInternal medicineSettore ING-IND/12 - Misure Meccaniche E TermicheHumansComputer SimulationInterventricular septumContraindicationRetrospective StudiesHeart Failurebusiness.industryHemodynamicsmedicine.disease020601 biomedical engineeringVentricleVentricular assist deviceHeart failureVentricular Function RightHeart-Assist DevicesbusinessCardiovascular Engineering and Technology
researchProduct

Three-dimensional parametric modeling of bicuspid aortopathy and comparison with computational flow predictions

2016

Bicuspid aortic valve (BAV)-associated ascending aneurysmal aortopathy (namely “bicuspid aortopathy”) is a heterogeneous disease making surgeon predictions particularly challenging. Computational flow analysis can be used to evaluate the BAV-related hemodynamic disturbances, which likely lead to aneurysm enlargement and progression. However, the anatomic reconstruction process is time consuming so that predicting hemodynamic and structural evolution by computational modeling is unfeasible in routine clinical practice. The aim of the study was to design and develop a parametric program for three-dimensional (3D) representations of aneurysmal aorta and different BAV phenotypes starting fr…

MalePatient-Specific ModelingBicuspid aortic valveComputed Tomography AngiographyHeart Valve DiseasesBiomedical EngineeringMedicine (miscellaneous)Bioengineering—Three-dimensional anatomic reconstructionElectrocardiographyImaging Three-DimensionalBicuspid Aortic Valve DiseaseSettore ING-IND/12 - Misure Meccaniche E TermicheHumans—Finite-element analysiProspective StudiesAortaAgedRetrospective Studies—Aortic failureHemodynamicsModels CardiovascularComputational BiologySettore ING-IND/34 - Bioingegneria IndustrialeMiddle AgedBiomaterialAortic Aneurysm—Ascending thoracic aortic aneurysmAortic ValveFemaleStress MechanicalSoftware
researchProduct

Particle image velocimetry study of the celiac trunk hemodynamic induced by continuous-flow left ventricular assist device

2017

Abstract Whereas left ventricular assist device (LVAD) is the gold-standard therapy for patients with heart failure, gastrointestinal bleeding is one of the most common complications. LVAD implantation may remarkably impact aortic hemodynamics so that experimental and computational flow analyses can be used to study the disease mechanisms. Here we present an experimentally-calibrated computational model of the celiac trunk hemodynamic of a LVAD-supported patient who experienced bleeding after device implantation. Specifically, both particle image velocimetry (PIV) and echocardiography were used to measure and compare flow distributions in each branch of a phantom model of the patient abdomi…

MalePatient-Specific ModelingCardiac outputLeft ventricular assist device (LVAD)medicine.medical_treatmentHemodynamicsBlood Pressure02 engineering and technology030204 cardiovascular system & hematology0302 clinical medicineCeliac ArteryParticle image velocimetry (PIV)Phantoms ImagingAbdominal aortaModels CardiovascularEquipment DesignMiddle AgedTreatment Outcomemedicine.anatomical_structureEchocardiographyCardiologyEquipment FailureRadiologyGastrointestinal HemorrhageRheologyBlood Flow VelocityArterymedicine.medical_specialty0206 medical engineeringBiomedical EngineeringBiophysicsAnastomosis03 medical and health sciencesInternal medicinemedicine.arterySettore ING-IND/12 - Misure Meccaniche E TermichemedicineHumansAbdominal aortaGastrointestinal bleedingbusiness.industrymedicine.disease020601 biomedical engineeringTrunkEquipment Failure AnalysisBiophysicVentricular assist deviceHeart failureHeart-Assist DevicesbusinessMedical Engineering & Physics
researchProduct

Shear stress alterations in the celiac trunk of patients with a continuous-flow left ventricular assist device as shown by in-silico and in-vitro flo…

2017

Background The use of left ventricular assist devices (LVADs) to treat advanced cardiac heart failure is constantly increasing, although this device leads to high risk for gastrointestinal bleeding. Methods Using in-silico flow analysis, we quantified hemodynamic alterations due to continuous-flow LVAD (HeartWare, Inc., Framingham, MA) in the celiac trunk and major branches of the abdominal aorta, and then explored the relationship between wall shear stress (WSS) and celiac trunk orientation. To assess outflow from the aortic branch, a 3-dimensional-printed patient-specific model of the celiac trunk reconstructed from an LVAD-supported patient was used to estimate echocardiographic outflow …

MalePulmonary and Respiratory Medicinemedicine.medical_specialtyLeft gastric arteryComputed Tomography Angiographyceliac trunkmedicine.medical_treatment0206 medical engineeringgastrointestinal bleedingHemodynamicsabdominal aorta02 engineering and technology030204 cardiovascular system & hematologyElectrocardiographycomputational fluid dynamic03 medical and health sciences0302 clinical medicineCeliac ArteryInternal medicinemedicine.arteryMultidetector Computed Tomographyleft ventricular assist deviceSettore ING-IND/12 - Misure Meccaniche E TermichemedicineHumansComputer SimulationTransplantationCommon hepatic arteryPhantoms Imagingbusiness.industryAbdominal aortaUltrasonography DopplerMiddle Agedmedicine.disease020601 biomedical engineeringTrunkOstiumVentricular assist deviceHeart failurecardiovascular systemCardiologyFemaleSurgeryHeart-Assist DevicesCardiology and Cardiovascular MedicinebusinessAlgorithmsBlood Flow VelocityThe Journal of Heart and Lung Transplantation
researchProduct

Le modifiche agli articoli 61, 572 e 612-bis del codice penale, nonché al codice delle leggi antimafia e delle misure di prevenzione (art. 9, l. 19 l…

2020

Il contributo si sofferma sulle modifiche agli artt. 61, 572 e 612-bis del codice penale, nonché al codice delle leggi antimafia e delle misure di prevenzione, dovute all'art. 9 della l. 19 luglio 2019, n. 69.

Maltrattamenti contro familiari e conviventimisure di prevenzioneatti persecutoriSettore IUS/17 - Diritto Penalecodice rosso
researchProduct

High frequency modeling technique for three phase power electronics module

2015

Nowadays, the high integrated power electronics modules (PMs), characterized by high speed, low loss and hard ware miniaturization, represent a new technology that meets the emerging demands of many applications, such us vehicle and home appliance, renewable energy sources in smart grid. The integration process and the high switching speeds increase the PM electromagnetic emissions that can create electromagnetic interference (EMI) with electric/electronic devices near the PMs. For this reason, electromagnetic compatibility (EMC) have to be carefully considered, yet in the design phase, to guarantee the reliability of PM systems. In this paper a method to develop a high frequency (HF) model…

MarketingEngineeringRenewable Energy Sustainability and the Environmentbusiness.industryElectromagnetic compatibilityEnergy Engineering and Power TechnologyPower moduleElectromagnetic interferenceElectromagnetic interferenceStrategy and Management1409 Tourism Leisure and Hospitality ManagementSmart gridEMIHigh frequency modelingPower modulePower electronicsMiniaturizationElectronic engineeringElectromagnetic compatibilityElectronicsbusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT)
researchProduct