Search results for "MISURE"

showing 10 items of 496 documents

Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy

2020

GAFChromic® HD-V2 film is a reliable dose measurement device, thin, flexible, inexpensive, simple to use and easy to analyze. The response in terms of net absorbance with respect to absorbed dose was found to be linear in a large dose range, which supports the feasibility of using the film dosimeters in many applications, such as radiotherapy. For its use, a "fogging" effect must be take into account since film response changes with time. To determine a calibration curve valid for any time, fogging effect was investigated for more than 400 days. A correction procedure allows the use of HD-V2 film dosimeters in high-dose radiotheraphy, as brachytherapy, and quality assurance (QA) procedures.

Materials scienceDosimeterFoggingbusiness.industryCalibration curveSettore ING-IND/20 - Misure E Strumentazione Nuclearimedicine.medical_treatmentBrachytherapydosimetry GAFChromic film gamma radiation radiotherapy030218 nuclear medicine & medical imagingRadiation therapy03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisAbsorbed dosemedicineDosimetrybusinessQuality assuranceBiomedical engineering
researchProduct

A novel multi-wavelength procedure for blood pressure estimation using opto-physiological sensor at peripheral arteries and capillaries

2018

© 2018 SPIE. In this study, the Carelight multi-wavelength opto-electronic patch sensor (OEPS) was adopted to assess the effectiveness of a new approach for estimating the systolic blood pressure (SBP) through the changes in the morphology of the OEPS signal. Specifically, the SBP was estimated by changing the pressure exerted on an inflatable cuff placed around the left upper arm. Pressure acquisitions were performed both with gold standard (i.e. electronic sphygmomanometer), and Carelight sensor (experimental procedure), on subjects from a multiethnic cohort (aged 28 ± 7). The OEPS sensor was applied together with a manual inflatable cuff, going slightly above the level of the SBP with in…

Materials scienceElectronic sphygmomanometerIdentification errorMulti wavelengthPeripheralInflatableBlood pressuremedicine.arteryCuffSettore ING-IND/12 - Misure Meccaniche E TermichemedicineRadial arteryblood pressure Multi-Wavelength opto-electronic patch sensor (OEPS) photopletismgraphy PPG systolic blood pressure wearable sensorBiomedical engineeringDesign and Quality for Biomedical Technologies XI
researchProduct

Simultaneous measurement of temperature and strain in glass fiber/epoxy composites by embedded fiber optic sensors: I. Cure monitoring

2007

In this paper (Part I) the use of fiber optic sensors for real-time monitoring of the cure kinetics of GFRP composites is explored. The proposed sensing system allows the simultaneous measurement of both temperature and strain by monitoring the change in reflected wavelength from two coupled fiber Bragg grating (FBG) sensors that have been embedded into the composite laminate. Instrumented GFRP laminates with 12, 18 and 24 reinforcing plies, respectively, were prepared by means of the vacuum bagging technique. Samples were cured in a thermally controlled oven at 80 degrees C and 30 kPa for 240 min (isothermal stage) and then cooled down to ambient temperature by turning off the heating sour…

Materials scienceFiber Bragg grating (FBG) sensorsComposite numberGlass fiberFiber Bragg gratingComposite cure monitoringSettore ING-IND/12 - Misure Meccaniche E TermicheSITUTemperature mesurementGeneral Materials ScienceCure monitoringElectrical and Electronic EngineeringComposite materialBRAGG GRATING SENSORSCivil and Structural EngineeringOptical fiber sensorEpoxyFibre-reinforced plasticCondensed Matter PhysicsTHERMOSETFiber Bragg grating (FBG) sensors; Optical fiber sensor; Composite cure monitoring; Strain measurement; Temperature mesurementAtomic and Molecular Physics and OpticsMechanics of MaterialsFiber optic sensorvisual_artSignal Processingvisual_art.visual_art_mediumEPOXY-RESINStrain measurementStructural health monitoringFIBRE/EPOXY COMPOSITESSYSTEM
researchProduct

Characterization of the ESR response of alanine dosimeters to low-energy Cu-target X-tube photons

2017

Abstract This article describes Electron Spin Resonance (ESR) response measurements of Kodak BioMax alanine films exposed to low-energy X-rays from a Cu-target tube operating at 20 kV. Commercial alanine detectors were used to ensure maximum reproducibility of the results, while the choice of a film was due the low penetration of the soft X-rays. X-ray energy spectra and fluences were determined with an innovative digital semiconductor detector system. These data were used to quantify the irradiation of the alanine films in terms of absorbed dose to water. The alanine films were found to present a stable response, highly linear with dose. To our knowledge, these data have not been previousl…

Materials sciencePhotonSettore ING-IND/20 - Misure E Strumentazione NucleariAnalytical chemistrySynchrotron radiationElectron Spin Resonance030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineNuclear magnetic resonancelawIrradiationElectron paramagnetic resonanceInstrumentationAlanineAlanine; Electron Spin Resonance; Low energy photons; Radiation; InstrumentationDosimeterLow energy photonsRadiationAlanineSettore FIS/01 - Fisica SperimentaleLow energy photonequipment and suppliesSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Semiconductor detector030220 oncology & carcinogenesisAbsorbed dose
researchProduct

Neutron ESR dosimetry through ammonium tartrate with low Gd content.

2014

This paper continues analyses on organic compounds for application in neutron dosimetry performed through electron spin resonance (ESR). Here, the authors present the results obtained by ESR measurements of a blend of ammonium tartrate dosemeters and gadolinium oxide (5 % by weight). The choice of low amount of Gd is due to the need of improving neutron sensitivity while not significantly influencing tissue equivalence. A study of the effect of gadolinium presence on tissue equivalence was carried out. The experiments show that the neutron sensitivity is enhanced by more than an order of magnitude even with this small additive content. Monte Carlo simulations on the increment of energy rele…

Materials scienceSettore ING-IND/20 - Misure E Strumentazione NucleariGadoliniumMonte Carlo methodAnalytical chemistrychemistry.chemical_elementGadoliniumRadiationRadiation Dosagelaw.inventionlawDosimetryRadiology Nuclear Medicine and imagingNeutronElectron paramagnetic resonanceRadiometryTartratesNeutronsRadiationRadiological and Ultrasound Technologyammonium tartratebusiness.industryPublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyResonanceGeneral MedicineESR Dosimetryneutron dosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryMeasuring instrumentNuclear medicinebusinessMonte Carlo MethodRadiation protection dosimetry
researchProduct

Gamma-ray spectrometric measurement of radionuclide purity of radiopharmaceuticals contained in bottle samples

2012

The radionuclide purity of a radiopharmaceutical product is usually measured by gamma-ray spectrometry with various measurement geometries. The importance of this test is that the radionuclide impurities, if present, result in an increase in the radiation dose to the patient without contributing to diagnostic information and in some cases may also interfere with the marking molecules and affect the proper conduct of diagnostic examination. In this work, gamma-ray spectrometry is used to determine the amounts of impurities by adopting as measurement geometry the same bottle containing eluted or prepared radiopharmaceuticals. In addition to high-purity germanium semiconductor detectors, the u…

Materials sciencebusiness.product_categorySettore ING-IND/20 - Misure E Strumentazione Nucleariradionuclide purityScintillatorMass spectrometrymedicineBottlelcsh:Nuclear and particle physics. Atomic energy. RadioactivitySafety Risk Reliability and Qualitygamma-ray spetrometryRadionuclidemedicine.diagnostic_testbusiness.industryElutionRadiochemistrydoseGamma raySemiconductor detectorPETNuclear Energy and EngineeringPositron emission tomographySPECTradionuclide purity PET SPECT gamma-ray spetrometry doselcsh:QC770-798businessNuclear medicine
researchProduct

Gamma-ray irradiation tests of CMOS sensors used in imaging techniques

2014

Technologically-enhanced electronic image sensors are used in various fields as diagnostic techniques in medicine or space applications. In the latter case the devices can be exposed to intense radiation fluxes over time which may impair the functioning of the same equipment. In this paper we report the results of gamma-ray irradiation tests on CMOS image sensors simulating the space radiation over a long time period. Gamma-ray irradiation tests were car ried out by means of IGS-3 gamma irradiation facility of Palermo Uni ver sity, based on 60Co sources with dif fer ent ac tiv i ties. To re duce the dose rate and re al ize a nar row gamma-ray beam, a lead-collimation sys tem was pur posely …

Materials scienceimaging technique CMOS image sensor gamma irradiationPixelSettore ING-IND/20 - Misure E Strumentazione Nuclearibusiness.industryImage qualityRadiationimaging techniqueSettore ING-INF/01 - Elettronicagamma irradiationBackground noiseNuclear Energy and EngineeringCMOSCMOS image sensorAbsorbed doseOptoelectronicslcsh:QC770-798lcsh:Nuclear and particle physics. Atomic energy. RadioactivityIrradiationImage sensorSafety Risk Reliability and QualitybusinessNuclear Technology and Radiation Protection
researchProduct

Incremental heuristic approach for meter placement in radial distribution systems

2019

The evolution of modern power distribution systems into smart grids requires the development of dedicated state estimation (SE) algorithms for real-time identification of the overall system state variables. This paper proposes a strategy to evaluate the minimum number and best position of power injection meters in radial distribution systems for SE purposes. Measurement points are identified with the aim of reducing uncertainty in branch power flow estimations. An incremental heuristic meter placement (IHMP) approach is proposed to select the locations and total number of power measurements. The meter placement procedure was implemented for a backward/forward load flow algorithm proposed by…

Mathematical optimizationControl and OptimizationComputer scienceHeuristic (computer science)020209 energyOptimal meter placementEnergy Engineering and Power Technology02 engineering and technologySmart gridlcsh:Technology0202 electrical engineering electronic engineering information engineeringMetrePower-flow studyInstrumentation (computer programming)Electrical and Electronic EngineeringEngineering (miscellaneous)optimal meter placement; smart grid; load flow analysis; Monte Carlo methodsRenewable Energy Sustainability and the Environmentlcsh:T020208 electrical & electronic engineeringMonte Carlo methodsLoad flow analysisPower (physics)Monte Carlo methodSmart gridLoad flow analysiSettore ING-INF/07 - Misure Elettriche E ElettronicheEnergy (miscellaneous)
researchProduct

Uncertainty evaluation in the differential measurements of power losses in a power drive system

2021

Abstract In order to guarantee a correct classification in the standardized energy efficiency classes, the current standards concerning the power drive systems prescribe that their power losses must be evaluated with great accuracy. This circumstance involves the usage of expensive measurement systems, since accurate instrumentation, skilled personnel and controlled environments are required. During the design stage of a power drive system, however, the measurement of the absolute value of its power losses is not always needed. Often, in fact, it is enough to assess the power losses variations caused by a modification of either hardware or software sections of the power drive system. In the…

Measure (data warehouse)Computer sciencebusiness.industryApplied MathematicsSystem of measurementAbsolute valueDifferential (mechanical device)Settore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciCondensed Matter PhysicsReliability engineeringPower (physics)SoftwarePower drive systems Power losses measurements Uncertainty analysisInstrumentation (computer programming)Electrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationEfficient energy useMeasurement
researchProduct

On the methodologies for the calibration of static electricity meters in the presence of harmonic distortion

2010

This paper is focused on the problems related to the calibration of static electricity meters with nonsinusoidal test waveforms. This is an up-to-date issue since the harmonic distortion levels are ever increasing, especially in low-voltage power systems, and in such conditions the performances of the modern static electricity meters can be negatively affected, depending on the implemented measurement algorithm. Thus it is important to test the meters with nonsinusoidal waveforms. The paper analyzes the problems related to both the choice of the test signals to be used for calibration and the implemented metric, with a particular focus on the reactive energy meters. The analysis is supporte…

Measurement algorithmNon-sinusoidal waveformCalibrationNon-sinusoidalEnergy meterHarmonic distortion levelLow-voltage power systemSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct