Search results for "Magnet"

showing 6 items of 15436 documents

An IPMSM torque/weight and torque/moment of inertia ratio optimization

2014

In this paper, a torque/weight and torque/moment of inertia ratio optimization procedure for interior permanent magnet syncronous motors (IPMSMs) is presented. More in detail, a performance comparison between several IPMSM rotor structures has been carried out in order to determine the optimum geometry that can maximize the torque/weight and torque/moment of inertia ratios. A commercial motor, with known electrical and mechanical characteristics, has been taken as reference. Its rotor structure has been modified several times, obtaining different rotor geometries and, therefore, many IPMSM models with different electrical and mechanical characteristics. The finite element method (FEM) analy…

ynchronous motorStall torquetorque-weight ratio optimizationMaterials scienceoptimisationpermanent magnet motorfinite element methodtorque-load-angle characteristicSettore ING-IND/32 - Convertitori Macchine E Azionamenti Elettricilaw.inventioninterior permanent magnet syncronous motorPermanent magnetmagnetisationControl theorylawRotorTorque sensorTorquetorque/weight ratioInduction motorDamping torqueFEM analysiLoad modelingTorque motorRotor (electric)finite element analysis;magnetisation;optimisation;permanent magnet motors;rotors;synchronous motors;IPMSM rotor structures;finite element method;interior permanent magnet syncronous motors;torque-load-angle characteristics;torque-moment of inertia ratio optimization;torque-weight ratio optimization;Induction motors;Load modeling;Permanent magnet motors;Permanent magnets;Rotors;Stators;Torque;FEM analysis;IPMSM;optimization;permanent magnets;torque/moment of inertia ratio;torque/weight ratioControl engineeringtorque-moment of inertia ratio optimizationStatorMoment of inertiafinite element analysiIPMSMDirect torque controlTorqueIPMSM rotor structureoptimizationtorque/moment of inertia ratio
researchProduct

Biodegradable Metal-Organic Framework-Based Microrobots (MOFBOTs).

2020

Microrobots and metal–organic frameworks (MOFs) have been identified as promising carriers for drug delivery applications. While clinical applications of microrobots are limited by their low drug loading efficiencies and the poor degradability of the materials used for their fabrication, MOFs lack motility and targeted drug delivery capabilities. The combination of these two fields marks the beginning of a new era; MOF‐based small‐scale robots (MOFBOTs) for biomedical applications. Yet, biodegradability is a major hurdle in the field of micro‐ and nanoswimmers including small‐scale robots. Here, a highly integrated MOFBOT that is able to realize magnetic locomotion, drug delivery, and selec…

zeolitic imidazolate frameworksMaterials scienceBiomedical EngineeringPharmaceutical ScienceNanotechnology02 engineering and technology010402 general chemistrybiodegradation01 natural sciencesBiomaterialsmetal–organic frameworksDrug Delivery SystemsNeoplasmsHumansMetal-Organic FrameworksBiodegradable metal021001 nanoscience & nanotechnologyControlled release0104 chemical sciencesMagnetic FieldsTargeted drug deliverySelective degradationDoxorubicindrug deliveryDrug deliverybiodegradation; drug delivery; metal–organic frameworks; microrobots; zeolitic imidazolate frameworksChemotherapeutic drugs0210 nano-technologymicrorobotsAdvanced healthcare materials
researchProduct

Experimental study of MMI structures in a switchable continuous-wave thulium-doped all-fiber laser

2022

Switchable multi-wavelength laser emission from a thulium-doped all-fiber laser is reported by implementing a tapered and a non-tapered multi-modal interference (MMI) filters. The MMI structure relies on a coreless optical fiber spliced in between two single-mode optical fibers. For the non-tapered case, a minimum insertion loss of 12.60 dB is achieved around the 2-μm region, from which stable generation of commutable dual-wavelength emission at 1986.34 nm and 2017.38 nm is obtained. On the other hand, the tapered MMI structure performs a minimum insertion loss of 8.74 dB at the 2-μm region, allowing a stable triple-wavelength emission at 1995.4 nm, 2013.3 nm, and 2038.3 nm. In addition, co…

ÒpticaElectrical and Electronic EngineeringAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsOptics & Laser Technology
researchProduct

Narrowband Monolithic Perovskite-Perovskite Tandem Photodetectors

2022

Narrowband photodetectors (PDs) are sought after for many applications requiring selective spectral response. The most common systems combine optical bandpass filters with broadband photodiodes. This work reports a method to obtain a narrowband response in a perovskite PD by the monolithic integration of a perovskite photoconductor and a perovskite photodiode. The spectral response of the tandem PD is determined by the bandgap energy difference of the two perovskites, and exhibits a full width at half maximum below 85 nm, an external quantum efficiency up to 68% and a high specific detectivity of ≈1012 Jones in reverse bias, enabling the device to detect weak light signals. The absorption p…

ÒpticaMaterialsAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials
researchProduct

Разработка и применение специальных численных методов для решения задач математической физики, гидродинамики и магнитной гидродинамики

1993

Математическая физикаMagnetohydrodynamics:NATURAL SCIENCES::Physics::Other physics::Mathematical physics [Research Subject Categories]МагнитогидродинамикаMatemātiskā fizikaMagnetohidrodinamikaHydrodynamicsГидродинамикаHidrodinamika
researchProduct

Магнитные взаимодействия и ориентационные явления в гидродинамике намагничивающихся жидкостей

1985

Ферромагнетики:NATURAL SCIENCES::Physics::Condensed matter physics [Research Subject Categories]Механика сплошных средMagnetohydrodynamicsPlūsmas mehānikaМагнитная гидродинамикаMagnetohidrodinamikaMagnetismElectromagnetic fieldFluid mechanicsГидродинамикаЭлектромагнитное поле
researchProduct