Search results for "Magnetic"
showing 10 items of 13720 documents
A half-metallic half-Heusler alloy having the largest atomic-like magnetic moment at optimized lattice constant
2016
For half-Heusler alloys, the general formula is XYZ, where X can be a transition or alkali metal element, Y is another transition metal element, typically Mn or Cr, and Z is a group IV element or a pnicitide. The atomic arrangements within a unit-cell show three configurations. Before this study, most of the predictions of half-metallic properties of half-Heusler alloys at the lattice constants differing from their optimized lattice constant. Based on the electropositivity of X and electronegativity of Z for half-Heusler alloys, we found that one of the configurations of LiCrS exhibits half-metallic properties at its optimized lattice constant of 5.803Å, and has the maximum atomic-like magn…
Guest Editorial
2019
Institute of Solid State Physics, University of Latvia as the Center of Excellence has received funding from the European Union’s Horizon 2020 Framework Programme H2020-WIDESPREAD-01-2016-2017-TeamingPhase2 under grant agreement No. 739508, project CAMART²
Rivalry of diffusion, external field and gravity in micro-convection of magnetic colloids
2019
Magnetic fields and magnetic materials have promising microfluidic applications. For example, magnetic micro-convection can enhance mixing considerably. However, previous studies have not explained increased effective diffusion during this phenomenon. Here we show that enhanced interface smearing comes from a gravity induced convective motion within a thin microfluidic channel, caused by a small density difference between miscible magnetic and non-magnetic fluids. This motion resembles diffusive behavior and can be described with an effective diffusion coefficient. We explain this with a theoretical model, based on a dimensionless gravitational Rayleigh number, and verify it by numerical si…
Conic optical fiber probe for generation and characterization of microbubbles in liquids
2021
Abstract A novel optical fiber probe has been developed to provide mechanical stability to microbubbles generated in fluids, the tip of the fiber is etched with hydrofluoric acid to pierce a truncated horn that fastens the microbubbles to the fiber tip and prevents misalignment or detachment caused by convection currents, vibrations or shocks in the liquid. Microbubbles are photo-thermally generated on the etched fiber and used as Fabry-Perot cavity sensor. Two methods were used to interrogate the probe: the first one, in the wavelength domain, is suitable for calibration in static or quasi static situations; the second one, in the time domain, can be used in dynamic environments. Experimen…
Determination of fine magnetic structure of magnetic multilayer with quasi antiferromagnetic layer by using polarized neutron reflectivity analysis
2020
We carried out polarized neutron reflectivity (PNR) analysis to determine the fine magnetic structure of magnetic multilayers with quasi-antiferromagnetic (quasi-AFM) layers realized by 90-deg coupling using two Co90Fe10 layers, and quantitatively evaluated the magnetization of quasi-AFM layers. Two types of samples with different buffer layers, Ru buffer and a NiFeCr buffer, were investigated and the average angles between the respective magnetization of the two Co90Fe10 layers were estimated to be +/− 39 degrees and +/− 53 degrees. In addition, less roughness was found in the NiFeCr buffer sample resulting stronger 90-deg coupling. A perfect quasi-AFM is expected to be realized by a flat …
A New Approach to Partial Discharge Detection Under DC Voltage: Application to Different Materials
2021
Usability of a new Direct Current Periodic waveform for partial discharge qualification in HVDC systems is exemplified by tests performed on different materials.
X-ray diffraction and Raman spectroscopy studies in Na1/2Bi1/2TiO3-SrTiO3-PbTiO3 solid solutions
2016
The long and short range orders in 0.4Na1/2Bi1/2TiO3-(0.6-x)SrTiO3-xPbTiO3 solid solutions were studied by x-ray diffraction and Raman spectroscopy. X-ray diffraction patterns for these composition...
Low energy nano diffraction (LEND) – A versatile diffraction technique in SEM
2019
Abstract Electron diffraction is a powerful characterization method that is used across different fields and in different instruments. In particular, the power of transmission electron microscopy (TEM) largely relies on the capability to switch between imaging and diffraction mode enabling identification of crystalline phases and in-depth studies of crystal defects, to name only examples. In contrast, while diffraction techniques have found their way into the realm of scanning electron microscopy (SEM) in the form of electron backscatter diffraction and related techniques, on-axis transmission diffraction is still in its infancy. Here we present a simple but versatile setup that enables a ‘…
Fast-ADT: A fast and automated electron diffraction tomography setup for structure determination and refinement.
2020
Abstract Electron crystallography has focused in the last few years on the analyses of microcrystals, mainly organic compounds, triggered by recent publications on acquisition methods based on direct detection cameras and continuous stage tilting. However, the main capability of a transmission electron microscope is the access to features at the nanometre scale. In this context, a new acquisition method, called fast and automated diffraction tomography (Fast-ADT), has been developed in form of a general application in order to get the most of the diffraction space from a TEM. It consists of two subsequent tilt scans of the goniometric stage; one to obtain a crystal tracking file and a secon…
Quasi-parallel precession diffraction: Alignment method for scanning transmission electron microscopes.
2018
Abstract A general method to set illuminating conditions for selectable beam convergence and probe size is presented in this work for Transmission Electron Microscopes (TEM) fitted with µs/pixel fast beam scanning control, (S)TEM, and an annular dark field detector. The case of interest of beam convergence and probe size, which enables diffraction pattern indexation, is then used as a starting point in this work to add 100 Hz precession to the beam while imaging the specimen at a fast rate and keeping the projector system in diffraction mode. The described systematic alignment method for the adjustment of beam precession on the specimen plane while scanning at fast rates is mainly based on …