Search results for "Masks"

showing 10 items of 49 documents

Aerosol filtration efficiency of household materials for homemade face masks: Influence of material properties, particle size, particle electrical ch…

2020

As a consequence of the COVID-19 pandemic caused by the SARS-CoV-2 virus, the widespread daily use of face masks is promoted worldwide. Particle-size dependent filtration efficiencies (FE; dp = 30 nm–10 µm), applying a particle counting approach, and additionally pressure drops (Δp) were determined for 44 samples of household materials and several medical masks. Huge FE differences were found between sample materials and for different particle sizes, spanning from <10% up to almost 100%. Minimum FE were determined for dp = 50–500 nm particles with significantly larger values for dp = 30 nm particles and especially for those with dp > 2.5 µm. Measurements at different numbers of layers…

Materials science010504 meteorology & atmospheric sciencesviruses010501 environmental sciences01 natural sciencesPollutionElectric chargelaw.inventionAerosolFace maskslawFace (geometry)Environmental ChemistryParticleGeneral Materials ScienceParticle sizeComposite materialMaterial propertiesFiltration0105 earth and related environmental sciencesAerosol Science and Technology
researchProduct

LMA Supreme™ and Ambu® AuraGain™ in anesthetized adult patients: a prospective observational study

2017

BACKGROUND Second-generation laryngeal masks with gastric access are increasingly used in daily practice and expand the indications for laryngeal masks in the OR. Only limited data exist comparing different types of laryngeal masks. We investigated the second-generation laryngeal masks LMA Supreme™ and Ambu® AuraGain™ in a clinical setting. We hypothesized that the two devices would be comparable in terms of success rate and airway complications. METHODS After approval from the local ethics committee, data were collected in a prospective trial. Endpoints were success rate, time to insertion and airway morbidity. Anesthesiologists used either the Supreme (Teleflex Medical GmbH) or Gain (Ambu…

Pediatricsmedicine.medical_specialtyAdult patientsbusiness.industryIncidence (epidemiology)030208 emergency & critical care medicine03 medical and health sciencesLaryngeal Masks0302 clinical medicineAnesthesiology and Pain MedicineInsertion time030202 anesthesiologyInterquartile rangeAnesthesiamedicineObservational studyAirwaybusinessProspective cohort studyMinerva Anestesiologica
researchProduct

Facial masks in children: the position statement of the Italian pediatric society

2020

AbstractFacial masks may be one of the most cost-effective strategies to prevent the diffusion of COVID 19 infection. Nevertheless, fake news are spreading, alerting parents on dangerous side effects in children, such as hypercapnia, hypoxia, gut dysbiosis and immune system weakness. Aim of the Italian Pediatric Society statement is to face misconception towards the use of face masks and to spread scientific trustable information.

Position statementWeakness2019-20 coronavirus outbreakmedicine.medical_specialtyConsensusCoronavirus disease 2019 (COVID-19)Pneumonia ViralFake newBetacoronavirus03 medical and health sciences0302 clinical medicineFacial mask030225 pediatricsDisease Transmission InfectiousmedicineHumansInfection control030212 general & internal medicinePsychiatryChildPandemicsChildrenCOVIDInfection ControlMaskPandemicBetacoronaviruSARS-CoV-2business.industryCoronavirus InfectionMaskslcsh:RJ1-570COVID-19lcsh:PediatricsEquipment DesignSettore MED/38Face masksDisease Transmission InfectiouFake newsCommentaryGut dysbiosisFake newsmedicine.symptomCoronavirus InfectionsbusinessHumanItalian Journal of Pediatrics
researchProduct

Management and use of filter masks in the “none-medical” population during the Covid-19 period

2020

Abstract SARS-CoV-2 has become a pandemic disease declared by the World Health Organization, consequently each nation has taken a series of actions managed by the government in order to prevent the spread of this dangerous virus. The most common countermeasure is the use of a mask that should cover the mouth and nose to filter the inhaled and exhaled air. Those masks are medical devices that should be handled properly; unfortunately in our study, observation of the population during the so-called “phase 2″ has very often shown an inappropriate use of any type of mask which reduces its effectiveness. The correct dissemination of adequate information on how to use the mask and the strict cont…

Proper behavioreducation.field_of_studyGovernmentCover (telecommunications)Coronavirus disease 2019 (COVID-19)Computer scienceSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)PopulationPublic Health Environmental and Occupational Healthmedicine.diseaseFilter (software)ArticleFiltering masksCountermeasureFiltering masks Covid-19 Proper behaviorPandemicmedicineMedical emergencyCovid-19Safety Risk Reliability and QualityeducationSafety ResearchSafety Science
researchProduct

How pediatricians in Spain manage the first acute wheezing episode in an atopic infant. Results from the TRAP study.

2005

Abstract Background Although the treatment of asthma has been addressed in several guidelines, the management of the first acute wheezing episode in infants has not often been evaluated. We surveyed practicing pediatricians in Spain about the treatment they would provide in a simulated case. Material and methods A random sample of 3000 pediatricians and physicians who normally treated children was surveyed. The questionnaire inquired about how they would treat a first mild-to-moderate wheezing attack in a 5-month-old boy with a personal and family history of allergy. Pediatricians were asked about their professional background. Results A total of 2347 questionnaires were returned with usefu…

Pulmonary and Respiratory MedicineHypersensitivity ImmediateAllergyPediatricsmedicine.medical_specialtyImmunologyAdrenergic beta-AntagonistsAdministration OralPrimary carePediatricsMaintenance therapyAdrenal Cortex HormonesAdrenergic beta-2 Receptor AntagonistsRecurrenceSurveys and QuestionnairesAdministration InhalationmedicineImmunology and AllergyHumansRespiratory soundsAnti-Asthmatic AgentsMetered Dose InhalersFamily historyPractice Patterns Physicians'AsthmaRespiratory Soundsmedicine.diagnostic_testBronchial Spasmbusiness.industryInhalerData CollectionMasksInfantGeneral Medicinemedicine.diseaseAsthmaSpainChild PreschoolOral steroidAcute DiseasePractice Guidelines as TopicDrug Therapy CombinationGuideline AdherencebusinessCase ManagementInhalation SpacersAllergologia et immunopathologia
researchProduct

Home Mechanical Ventilation in Amyotrophic Lateral Sclerosis Patients Is Not Always a Problem

2000

Pulmonary and Respiratory MedicineMechanical ventilationmedicine.medical_specialtybusiness.industrymedicine.medical_treatmentMasksCritical Care and Intensive Care Medicinemedicine.diseaseHome Care ServicesPositive-Pressure RespirationTracheostomyPhysical medicine and rehabilitationQuality of LifemedicineHumansMotor Neuron DiseaseAmyotrophic lateral sclerosisCardiology and Cardiovascular MedicinebusinessChest
researchProduct

Reducing Rebreathing During Noninvasive Ventilation: Bias Flow or No Bias Flow?

2019

To the Editor : We read with interest the article by Signori et al[1][1] that evaluated CO2 rebreathing during noninvasive ventilation (NIV) via a full face mask connected to a double-limb ventilation circuit with 2 different configurations: (1) a single mask connector directly attached to the Y-

Pulmonary and Respiratory MedicineNoninvasive Ventilationbusiness.industryMasksleakGeneral MedicineCritical Care and Intensive Care Medicinelaw.invention03 medical and health sciences0302 clinical medicine030228 respiratory systemFlow (mathematics)lawflowVentilation (architecture)MedicineNoninvasive ventilationCardiac OutputbusinessBiomedical engineeringRespiratory care
researchProduct

Material and Technology: Back to the Future for the Choice of Interface for Non-Invasive Ventilation – A Concise Review

2020

Non-invasive ventilation (NIV) has dramatically changed the treatment of both acute and chronic respiratory failure in the last 2 decades. The success of NIV is correlated to the application of the “best ingredients” of a patient’s “tailored recipe,” including the appropriate choice of the selected candidate, the ventilator setting, the interface, the expertise of the team, and the education of the caregiver. The choice of the interface is crucial for the success of NIV. Type (oral, nasal, nasal pillows, oronasal, hybrid mask, helmet), size, design, material and headgears may affect the patient’s comfort with respect to many aspects, such as air leaks, claustrophobia, skin erythema, eye irr…

Pulmonary and Respiratory MedicineRespiratory failure.medicine.medical_specialtySkin erythemamedicine.medical_treatmentInterface (computing)Skin breakdownlaw.invention03 medical and health sciencesFacial deformity0302 clinical medicinelawHumansMedicine030212 general & internal medicineIntensive care medicineReduction (orthopedic surgery)Noninvasive VentilationContinuous Positive Airway Pressurebusiness.industryMasksEquipment DesignHome ventilationInterfacemedicine.diseaseHome setting030228 respiratory systemVentilation (architecture)Non-invasive ventilationClaustrophobiaRespiratory Insufficiencybusiness
researchProduct

Comparative bench study evaluation of different infant interfaces for non-invasive ventilation

2018

Abstract Background To compare, in terms of patient-ventilator interaction and performance, a new nasal mask (Respireo, AirLiquide, FR) with the Endotracheal tube (ET) and a commonly used nasal mask (FPM, Fisher and Paykel, NZ) for delivering Pressure Support Ventilation (PSV) in an infant model of Acute Respiratory Failure (ARF). Methods An active test lung (ASL 5000) connected to an infant mannequin through 3 different interfaces (Respireo, ET and FPM), was ventilated with a standard ICU ventilator set in PSV. The test lung was set to simulate a 5.5 kg infant with ARF, breathing at 50 and 60 breaths/min). Non-invasive ventilation (NIV) mode was not used and the leaks were nearly zero. Res…

Pulmonary and Respiratory Medicinemedicine.medical_specialtyAcute respiratory failure; Bench test; Infant mask; Mechanical ventilation; Non invasive ventilation; Patient-ventilator interactionRespiratory ratemedicine.medical_treatmentPressure support ventilationAcute respiratory failureManikinsBench test03 medical and health sciences0302 clinical medicineMechanical ventilationRespiratory Rate030225 pediatricsInternal medicineSettore MED/41 - ANESTESIOLOGIAIntubation IntratrachealTidal VolumeMedicineNon-invasive ventilationHumansTidal volumePatient-ventilator interactionMonitoring PhysiologicWork of BreathingMechanical ventilationlcsh:RC705-779LungNoninvasive Ventilationbusiness.industryMasksInfantNon invasive ventilationlcsh:Diseases of the respiratory systemAcute respiratory failure; Bench test; Infant mask; Mechanical ventilation; Non invasive ventilation; Patient-ventilator interaction; Pulmonary and Respiratory Medicinemedicine.anatomical_structure030228 respiratory systemVolume (thermodynamics)ItalyAcute DiseaseBreathingCardiologyInfant maskbusinessRespiratory InsufficiencyResearch ArticleBMC Pulmonary Medicine
researchProduct

Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study

2015

BACKGROUND: In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive respiratory conditions. METHODS: A test lung, connected to a pediatric mannequin using different interfaces (endotracheal tube [ETT], face mask, and helmet), was ventilated in pressure support ventilation mode testing 2 ventilator settings (pressurization time [Timepress]50%/cycling-off flow threshold [T…

Pulmonary and Respiratory Medicinemedicine.medical_specialtyRespiratory rateface maskPositive pressurePressure support ventilationRespiratory physiologyCritical Care and Intensive Care MedicineManikinsManikinPositive-Pressure Respirationendotracheal tubepatient-ventilator interactionSettore MED/41 - ANESTESIOLOGIAmedicineIntubation IntratrachealHumansIntensive care medicineChildInteractive Ventilatory Supportpressure-support ventilationLungVentilators MechanicalMaskRespiratory MechanicHead Protective Devicebusiness.industryRespirationMaskshelmetnoninvasive ventilationGeneral Medicinemedicine.anatomical_structureAnesthesiaBreathingRespiratory MechanicsHead Protective DevicesAirwaybusinessInteractive Ventilatory SupportHuman
researchProduct