Search results for "Matrix"

showing 10 items of 3205 documents

Size Exclusion Chromatography for Semipreparative Scale Separation of Au 38 (SR) 24 and Au 40 (SR) 24 and Larger Clusters

2011

Size exclusion chromatography (SEC) on a semipreparative scale (10 mg and more) was used to size-select ultrasmall gold nanoclusters (2 nm) from polydisperse mixtures. In particular, the ubiquitous byproducts of the etching process toward Au(38)(SR)(24) (SR, thiolate) clusters were separated and gained in high monodispersity (based on mass spectrometry). The isolated fractions were characterized by UV-vis spectroscopy, MALDI mass spectrometry, HPLC, and electron microscopy. Most notably, the separation of Au(38)(SR)(24) and Au(40)(SR)(24) clusters is demonstrated.

ChromatographyChemistrySize-exclusion chromatographyAnalytical chemistry02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnologyMass spectrometry01 natural sciencesHigh-performance liquid chromatography0104 chemical sciencesAnalytical ChemistryNanoclusterslaw.inventionGel permeation chromatographyMatrix-assisted laser desorption/ionizationlawddc:540Electron microscope0210 nano-technologySpectroscopy
researchProduct

Electrothermal Atomic Absorption Spectrometric Diagnosis of Familial Hypercholesterolemia

2000

We have developed a new nonradioactive assay to identify human low-density lipoprotein receptor defects. It is based on the incubation of cultured cells with colloidal gold-LDL conjugates and quantitation of the gold associated with the cells by electrothermal atomic absorption spectrometry. After an oxidative treatment with nitric and hydrochloric acids, the biological matrix interferes neither with the gold recovery nor with the gold measurements, which are linear, at least from 0.15 to 3 ng of gold. When cells expressing a functional LDL receptor are incubated with increasing amounts of colloidal-gold LDL conjugates, the obtained saturation curve parallels that described when [125I]LDL i…

ChromatographyChemistrySpectrophotometry AtomicCholesterol LDLGold ColloidFamilial hypercholesterolemiamedicine.diseaseLigand (biochemistry)Analytical ChemistryHyperlipoproteinemia Type IIMatrix (chemical analysis)PhenotypeReceptors LDLBiochemistryCell cultureCOS CellsLDL receptormedicineAnimalsHumansSaturation vapor curveReceptorLipoproteinAnalytical Chemistry
researchProduct

An automated on-line multidimensional HPLC system for protein and peptide mapping with integrated sample preparation.

2002

A comprehensive on-line two-dimensional 2D-HPLC system with integrated sample preparation was developed for the analysis of proteins and peptides with a molecular weight below 20 kDa. The system setup provided fast separations and high resolving power and is considered to be a complementary technique to 2D gel electrophoresis in proteomics. The on-line system reproducibly resolved approximately 1000 peaks within the total analysis time of 96 min and avoided sample losses by off-line sample handling. The low-molecular-weight target analytes were separated from the matrix using novel silica-based restricted access materials (RAM) with ion exchange functionalities. The size-selective sample fr…

ChromatographyIon exchangeChemistryIon chromatographyAnalytical chemistryProteinsUltrafiltrationFibroblastsMass spectrometryChromatography Ion ExchangeHigh-performance liquid chromatographyOnline SystemsPeptide MappingAnalytical ChemistryCell LineMatrix (chemical analysis)Matrix-assisted laser desorption/ionizationTwo-dimensional chromatographySpectrometry Mass Matrix-Assisted Laser Desorption-IonizationHumansSample preparationElectrophoresis Polyacrylamide GelChromatography High Pressure LiquidAnalytical chemistry
researchProduct

Error analysis and performance of different retention models in the transference of data from/to isocratic/gradient elution.

2003

The transferability of retention data among isocratic and gradient RPLC elution modes is studied. For this purpose, 16 beta-blockers were chromatographed under both isocratic and gradient elution with acetonitrile-water mobile phases. Taking into account the elution mode where the experimental data come from, and the mode where the retention should be predicted, the following combinations are possible: isocratic predictions from (i) isocratic or (ii) gradient experimental designs; and gradient predictions from (iii) isocratic or (iv) gradient data. Each of these possibilities was checked using three retention models that relate the logarithm of the retention factor: (a) linearly and (b) qua…

ChromatographyLogarithmChemistryElutionOrganic ChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographyBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)Phase (matter)Volume fractionConfidence IntervalsGradient elutionChromatography LiquidJournal of chromatography. A
researchProduct

MALDI-TOF characterization of macromonomers

1996

Methacryloyl endfunctionalized oligostyrene macromonomers were characterized by matrix assisted laser desorption ionization/time of flight (MALDI-TOF) spectroscopy and by isocratic and gradient high performance liquid chromatography (HPLC). The molar mass distribution derived by the different techniques coincide for the investigated oligomers. Mixing experiments revealed that the MALDI-TOF peak areas do not necessarily represent the mixing ratio of the components. Combination of gradient HPLC and MALDI-TOF has resolved the chemical composition of the coupling products formed by reaction of the living anion with oxygen.

ChromatographyPolymers and PlasticsChemistryOrganic ChemistryMatrix isolationAnalytical chemistryMass spectrometryMacromonomerHigh-performance liquid chromatographyTime of flightMatrix-assisted laser desorption/ionizationMaterials ChemistryMolar mass distributionSpectroscopyMacromolecular Rapid Communications
researchProduct

Optimization of iron speciation (soluble, ferrous and ferric) in beans, chickpeas and lentils

2001

Abstract A spectrophotometric method with bathophenanthroline for iron determination that makes it possible to differentiate between iron (II) and iron (III) in total soluble iron in legumes (beans, chickpeas and lentils) was optimized. Sample size, volumes of reducing agent and bathophenanthroline were selected. Matrix interferences made it necessary to apply the addition’s method. To check the quality of the method, linearity and precision (RSD%) were determined. A linear response between 0.1 and 1.8 μg Fe/ml in the assay and precision values ranging from 2.1 to 6 for instrumental precision, and from 1.6 to 1.7 and 2.7 to 9.1, for intra- and inter-day assays, respectively were obtained. T…

ChromatographyReducing agentChemistrymedia_common.quotation_subjectMetallurgySoluble ironGeneral MedicineAnalytical ChemistryFerrousMatrix (chemical analysis)SpeciationmedicineFerricDry matterFood Sciencemedicine.drugmedia_commonFood Chemistry
researchProduct

Commercial thickeners used by patients with dysphagia: Rheological and structural behaviour in different food matrices

2015

In order to achieve a safe swallowing in patients with dysphagia, liquids must be thickened. In this work, two commercial starch based thickeners dissolved inwater,whole milk, apple juice and tomato juice were studied. The thickeners were Resource®, composed of modified maize starch and Nutilis®, composed of modified maize starch and gums. They were formulated at two different concentrations corresponding to nectar- and pudding-like consistencies. Influence of composition, concentration and food matrix on rheological properties and structure of the resulting pastes were analysed. Viscoelastic measurements and microscopic observations of the thickeners dissolved in water revealed structural …

ChromatographyTECNOLOGIA DE ALIMENTOSStarchGeneral Chemical Engineeringfood and beveragesGeneral ChemistryDysphagiaViscoelasticityMaize starchViscositychemistry.chemical_compoundMatrix (mathematics)GumRheologychemistryThickenersComposition (visual arts)Food scienceStructured systemsRheologyMicrostructureFood Science
researchProduct

Development of a species-unspecific isotope dilution GC-ICPMS method for possible routine quantification of sulfur species in petroleum products.

2008

Inductively coupled plasma mass spectrometry (ICPMS) hyphenated with capillary gas chromatography was applied for sulfur multispecies determination in petroleum products by species-unspecific isotope dilution mass spectrometry (IDMS). To guarantee a stable and continuous addition of the spike into the GC-ICPMS system, a special dosing unit was designed and synthesis of a (34)S-labeled dimethyldisulfide spike from (34)S-enriched elemental sulfur in the milligram range was developed. The sample was mixed with an internal standard for spike mass flow calibration. From the mass flow chromatogram obtained by species-unspecific GC-ICP-IDMS, determination of all separated sulfur species and of the…

Chromatographybusiness.industrychemistry.chemical_elementIsotope dilutionMass spectrometrySulfurAnalytical ChemistryMatrix (chemical analysis)Petroleum productchemistryIon trapGas chromatographybusinessInductively coupled plasma mass spectrometryAnalytical chemistry
researchProduct

ORGANIZATION OF HIGHER-LEVEL CHROMATIN STRUCTURES (CHROMOMERE, CHROMONEMA AND CHROMATIN BLOCK) EXAMINED USING VISIBLE LIGHT-INDUCED CHROMATIN PHOTO-S…

2002

The method of chromatin photo-stabilization by the action of visible light in the presence of ethidium bromide was used for investigation of higher-level chromatin structures in isolated nuclei. As a model we used rat hepatocyte nuclei isolated in buffers which stabilized or destabilized nuclear matrix. Several higher-level chromatin structures were visualized: 100 nm globules—chromomeres, chains of chromomeres—chromonemata, aggregates of chromomeres—blocks of condensed chromatin. All these structures were completely destroyed by 2 M NaCl extraction independent of the matrix state, and DNA was extruded from the residual nuclei (nuclear matrices) into a halo. These results show that nuclear …

ChromomereLightPhotochemistrySolenoid (DNA)BuffersBiologyRadiation Dosagechemistry.chemical_compoundMicroscopy Electron TransmissionNuclear Matrix-Associated ProteinsEthidiumAnimalsNucleoidChromatin structure remodeling (RSC) complexInterphaseCell NucleusCell BiologyGeneral MedicineNuclear matrixMolecular biologyChromatinProtein Structure TertiaryRatsChromatinDNA-Binding ProteinschemistryHepatocytesBiophysicsbiology.proteinInterphaseDNASubcellular FractionsCell Biology International
researchProduct

Tight DNA-protein complexes isolated from barley seedlings are rich in potential guanine quadruplex sequences

2020

Background The concept of chromatin domains attached to the nuclear matrix is being revisited, with nucleus described as a set of topologically associating domains. The significance of the tightly bound to DNA proteins (TBP), a protein group that remains attached to DNA after its deproteinization should be also revisited, as the existence of these interactions is in good agreement with the concept of the topologically associating domain. The work aimed to characterize the DNA component of TBP isolated from barley seedlings. Methods The tight DNA-protein complexes from the first leaves, coleoptiles, and roots of barley seedlings were isolated by purification with chromatography on nitrocell…

Circular dichroismGuaninelcsh:MedicinePlant ScienceGC-rich DNAG-quadruplexDeproteinisation-resistant DNA-protein complexesGeneral Biochemistry Genetics and Molecular Biology03 medical and health scienceschemistry.chemical_compoundBarleyMolecular Biology030304 developmental biology0303 health sciencesOligonucleotideChemistryGeneral Neurosciencelcsh:R030302 biochemistry & molecular biologyStructural geneCell BiologyGenomicsGeneral MedicineNuclear matrixG-quadruplexesChromatinBiochemistryGeneral Agricultural and Biological SciencesDNAPeerJ
researchProduct