Search results for "Maxim"
showing 10 items of 1236 documents
Compensation of missing wedge effects with sequential statistical reconstruction in electron tomography.
2014
Electron tomography (ET) of biological samples is used to study the organization and the structure of the whole cell and subcellular complexes in great detail. However, projections cannot be acquired over full tilt angle range with biological samples in electron microscopy. ET image reconstruction can be considered an ill-posed problem because of this missing information. This results in artifacts, seen as the loss of three-dimensional (3D) resolution in the reconstructed images. The goal of this study was to achieve isotropic resolution with a statistical reconstruction method, sequential maximum a posteriori expectation maximization (sMAP-EM), using no prior morphological knowledge about …
Stark broadening of the hydrogen Paschen ? transition at electron densities of the order of $ \mathsf {10^{15}}$ cm $ \mathsf {^{-3}}$
2003
Stark broadening measurements and calculations of the Paschen γ spectral line of hydrogen ( λ = 1.094[: MU :] m) are reported. Investigations have been performed at plasma electron densities between 1.4×10 15 cm -3 and 3.7×10 15 cm -3 . As the light source a wall-stabilized arc operated in a helium-hydrogen gas mixture at atmospheric pressure has been applied. The radiation of the plasma emitted from nearly homogeneous plasma layers in end-on direction, was measured with the use of a grating spectrometer equipped with a charge coupled device (CCD) detector. The radiance calibration was carried out against light outputs originating from a tungsten strip radiation standard. The measured FWHM …
Calibration of the width of the NI spectral line at for electron density determination
2002
Abstract The Stark broadening of a NI spectral line at 7915.42 A has been calibrated for electron density determination of low temperature plasmas. The determined simple formula based on measured FWHM is applicable in the electron density range from 3×1015 to 10 16 cm −3 .
Outdoor Performance of 10 year Old a-Si and Poly-Si Modules in southern Norway conditions
2012
The outdoor performance of 10 years modules has been measured in southern Norway conditions. For this study, Poly-Si and a-Si modules are selected and the measurements are carried out using a portable electronic load. The I–V characteristics and maximum power have been recorded for several modules of each technology. It is found that Poly-Si modules perform very well even after 10 years of span whereas some of a-Si modules have visual degradation which causes significant power losses. The experimentally outdoor monitored values of P mp , V mp , short circuit current (I sc ), Open circuit voltage (V oc ) and efficiency for different modules are compared with manufacturer's values.
Least energy solutions to the Dirichlet problem for the equation −D(u) = f (x, u)
2017
Let be a bounded smooth domain in RN. We prove a general existence result of least energy solutions and least energy nodal ones for the problem −u = f(x, u) in u = 0 on ∂ (P) where f is a Carathéodory function. Our result includes some previous results related to special cases of f . Finally, we propose some open questions concerning the global minima of the restriction on the Nehari manifold of the energy functional associated with (P) when the nonlinearity is of the type f(x, u) = λ|u| s−2u − μ|u| r−2u, with s, r ∈ (1, 2) and λ,μ > 0.
Design, assembly and characterization of silicide-based thermoelectric modules
2016
ID: 1143 In: Energy conversion and management, 13-21. Summary: Highlights•Novel silicide-based thermoelectric modules were experimentally investigated.•The modules produced high power of 1.04 W at 405 °C and 3.24 W at 735 °C.•An estimated module efficiency of 5.3% represent the highest reported for silicide systems.AbstractSilicides have attracted considerable attention for use in thermoelectric generators due mainly to low cost, low toxicity and light weight, in contrast to conventional materials such as bismuth and lead telluride. Most reported work has focused on optimizing the materials properties while little has been done on module testing. In this work we have designed and tested mod…
A mixed FES/EMG system for real time analysis of muscular fatigue
2010
International audience; In this article, we present a functional electrical stimulator allowing the extraction in real time of M-wave characteristics from resulting EMG recodings in order to quantify muscle fatigue. This system is composed of three parts. A Labview software managing the stimulation output and electromyogram (EMG) input signal, a hardware part amplifying the output and input signal and a link between the two previous parts which is made up from input/output module (NIdaq USB 6251). In order to characterize the fatigue level, the Continuous Wavelet Transform is applied yielding a local maxima detection. The fatigue is represented on a scale from 0 for a fine shaped muscle to …
Control and power management of Photovoltaic-battery based micro grid
2016
The growing demand for electrical power and the interruption of the power supply has paved the way for the realization of renewable based energy generation. This paper presents the control and power management of a hybrid microgrid system that comprises Photovoltaic (PV) array, battery, and local AC load, connected to the utility grid. This work focuses on the compensation of PV power reduction due to partial shading using bidirectional half bridge converter with battery storage. This system considers fulfilling the local load demand through PV production and, then, to manage the power among the battery and grid. In the proposed system, the considered power conditioning devices area boost c…
Analytical Investigation and Control System Set-up of Medium Scale PV Plants for Power Flow Management
2012
In the field of photovoltaic (PV) plants and energy conversion from renewable sources, a large part of the technical literature is more devoted to practical aspects (new solar cells, electrically driven PV panels, safety, reduction of parasitic currents, etc.) than to theoretical investigations. Despite this tendency, this paper presents a mathematical analysis of a medium scale photovoltaic power generation system connected to the distribution network and of its control system. In such a system, the conversion stage is unique due to the absence of a boost chopper. The conducted analysis leads to the interesting conclusion that the inverter used in the plant presents two degrees of freedom,…
The Sequential Switching Shunt Maximum Power Regulator and its Application in the Electric Propulsion System of a Spacecraft
2007
This paper describes a baseline solution of a Power Conditioning and Distribution Unit (PCDU) for Electrical Propulsion (EP) systems. The solution adopted uses two high efficiency, low-mass power regulators; a solar array regulator (SAR) based on the classical Sequential Switching Shunt Regulator with Maximum Power Point Tracking (MPPT) capability followed by a step-up converter to achieve the desired regulated bus voltage. This paper focuses on the first part of the PCDU, the Sequential Switching Shunt Maximum Power Regulator (S3MPR). This electrical architecture has been adapted and recently proposed for the Electric Propulsion power system of the European and Japanese Mercury Mission (Be…