Search results for "Measurement"
showing 10 items of 2918 documents
Interaction of hyperalgesia and sensory loss in complex regional pain syndrome type I (CRPS I).
2008
Background: Sensory abnormalities are a key feature of Complex Regional Pain Syndrome (CRPS). In order to characterise these changes in patients suffering from acute or chronic CRPS I, we used Quantitative Sensory Testing (QST) in comparison to an age and gender matched control group. Methods: 61 patients presenting with CRPS I of the upper extremity and 56 healthy subjects were prospectively assessed using QST. The patients’ warm and cold detection thresholds (WDT; CDT), the heat and cold pain thresholds (HPT; CPT) and the occurrence of paradoxical heat sensation (PHS) were observed. Results: In acute CRPS I, patients showed warm and cold hyperalgesia, indicated by significant changes in H…
Pulpal ischemia in man: effects on detection threshold, A-delta neural response and sharp dental pain
1999
— Preferential blocks of peripheral nerves have shown that myelinated nerves are more susceptible to local compression and less resistent to asphyxia than unmyelinated fibers. Since two groups of functionally different nociceptors exist in the dental pulp, it is of theoretical and clinical interest to determine the influence of ischemia on the sensitivity of human dental pulp, using standard means for testing tooth vitality and at the same time investigating the intensity coding in one pathway of the afferent trigeminal system. Adrenaline was used to study the differential effect of adrenaline-induced ischemia on intradental A-delta nerve activity (INA) and the concomitant sharp pain, as we…
Hypnotic hypo- and hyperalgesia: divergent effects on pain ratings and pain-related cerebral potentials.
1993
Pain ratings and pain-related cerebral potentials in response to noxious stimuli were investigated under hypnotic hypo- or hyperalgesia. Out of a sample of 50 subjects the 10 most highly hypnotizable were selected using the Stanford Hypnotic Susceptibility Scale. Phasic pain was induced by brief electrical stimuli intracutaneously applied to the subject's left middle finger. The subjects took part in three experimental sessions. The first session was without hypnosis for familiarization with the experimental surroundings. In the two other sessions, the subjects were hypnotized and given a suggestion of analgesia or hyperalgesia with respect to pain sensation in the left hand. The sequence o…
Asymmetric metabolic profile in mesial temporal lobes: Localized H-1 MR spectroscopy in healthy right-handed and non-right-handed subjects
1996
International audience; Abstract: PURPOSE: To determine a possible asymmetric metabolic profile in right-handed and non-right-handed healthy subjects by comparing proton spectra from temporal lobes. MATERIALS AND METHODS: Twenty-eight healthy adults (17 right-handers, 11 non-right-handers) underwent magnetic resonance (MR) imaging and single-voxel MR spectroscopy. N-acetylaspartate (NAA), choline (Cho), and creatine (Cr) peak areas were measured. RESULTS: Volume of hippocampal formations was larger on the right in right-handers (right volume: 4.04 cm(3) +/- 0.67 vs left volume: 3.84 cm(3) +/- 0.62; P = .00004) and in non-right-handers (right volume: 4.22 cm(3) +/- 0.78 vs left volume: 4.05 …
Instantaneous Transfer Entropy for the Study of Cardiovascular and Cardio-Respiratory Nonstationary Dynamics
2017
Objective: Measures of transfer entropy (TE) quantify the direction and strength of coupling between two complex systems. Standard approaches assume stationarity of the observations, and therefore are unable to track time-varying changes in nonlinear information transfer with high temporal resolution. In this study, we aim to define and validate novel instantaneous measures of TE to provide an improved assessment of complex nonstationary cardiorespiratory interactions. Methods: We here propose a novel instantaneous point-process TE (ipTE) and validate its assessment as applied to cardiovascular and cardiorespiratory dynamics. In particular, heartbeat and respiratory dynamics are characteriz…
The efficacy of acupuncture in human pain models: A randomized, controlled, double-blinded study
2012
Acupuncture is frequently used to treat pain, although data supporting the analgesic efficacy from placebo-controlled studies is sparse. In order to get evidence for acupuncture analgesia we performed a study with 2 well-recognized experimental human pain models - the cold-pressor (CP) test and intradermal capsaicin injection. Fifty healthy men were included. Our study compared Traditional Chinese Medicine-based acupuncture to sham acupuncture with Streitberger placebo needles in a randomized, controlled, double-blinded trial. The primary endpoint was the reduction of mean pain intensity during 3minutes of CP test or of mean pain intensity within 10minutes after capsaicin injection. Seconda…
Noninvasive measurement of intracranial pressure: Is it possible?
2007
BACKGROUND: Some publications suggest a strong correlation between the intracranial pressure and the intraocular pressure. Other studies claim no correlation between these two physiologic variables. Our aim was to study whether the tonometry could be a useful method to evaluate intracranial pressure in patients with suspected intracranial abnormality. METHODS: We evaluated the correlation between the intracranial pressure and the intraocular pressure, the intracranial pressure and the mean arterial pressure, and the intraocular pressure and the mean arterial pressure in 22 patients, initially comatose, who were admitted to our hospital. All patients required the intracranial pressure monito…
Single region of interest versus multislice T2* MRI approach for the quantification of hepatic iron overload.
2011
Purpose To evaluate the effectiveness of the single ROI approach for the detection of hepatic iron burden in thalassemia major (TM) patients in respect to a whole liver measurement. Materials and Methods Five transverse hepatic slices were acquired by a T2* gradient-echo sequence in 101 TM patients and 20 healthy subjects. The T2* value was calculated in a single region of interest (ROI) defined in the medium-hepatic slice. Moreover, the T2* value was extracted on each of the eight ROIs defined in the functionally independent segments. The mean hepatic T2* value was calculated. Results For patients, the mean T2* values over segments VII and VIII were significantly lower. This pattern was su…
Volumetry of Ventilated Airspaces by 3He MRI
2001
To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI.3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated.Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,…
Amplitudes of laser evoked potential recorded from primary somatosensory, parasylvian and medial frontal cortex are graded with stimulus intensity
2003
Intensity encoding of painful stimuli in many brain regions has been suggested by imaging studies which cannot measure electrical activity of the brain directly. We have now examined the effect of laser stimulus intensity (three energy levels) on laser evoked potentials (LEPs) recorded directly from the human primary somatosensory (SI), parasylvian, and medial frontal cortical surfaces through subdural electrodes implanted for surgical treatment of medically intractable epilepsy. LEP N2* (early exogenous/stimulus-related potential) and LEP P2** (later endogenous potential) amplitudes were significantly related to the laser energy levels in all regions, although differences between regions w…