Search results for "Measurement"
showing 10 items of 2918 documents
Development of an Inductive NIS Thermometer
2012
We have studied an inductive readout for normal metal-insulator-superconductor (NIS) tunnel junctions by using on-chip planar inductors and a DC SQUID (superconducting quantum interference device) to develop a sensitive and fast thermometer for studies of nanoscale heat conduction and bolometry. Our initial results show the feasibility of the concept, with a good sensitivity for temperatures below 1 K for aluminum as the superconductor when voltage biased close to the superconductor energy gap. peerReviewed
Superconducting properties of polycrystalline YBCO prepared by a pyrolytic process
1994
Polycrystalline YBCO was prepared by a pyrolytic process starting from citrate and tartrate precursors. The effect of the precursor on the superconducting properties was investigated by means of magnetic measurements using a SQUID magnetometer, a Vibrating-Sample Magnetometer and an a.c. susceptometer. The critical temperature is not affected by the type of precursor (Tc=85 K for both). On the other hand, the precursor plays an important role on the critical current density, which is found to be an order of magnitude higher in the sample obtained from citrates (Jc(77K, H=0)=2.3·104 A/cm2 and 103 A/cm2 for the from-citrate and from-tartrate sample, respectively).
Estimating the difference between brightness and surface temperatures for a vegetal canopy
1995
Abstract The difference between the surface temperature T S and the brightness temperature T b , which can be measured with a thermal infrared radiometer, has been calculated for different surface emissivity values and different atmospheric conditions. These calculations show that T s − T b is often significant even for high surface emissivities and that the spectral band in which the measurements are performed is a key factor in the interpretation of T s − T b . In particular, it is not a simple matter to use the characterisation of the whole spectrum atmospheric radiation to derive T s from T b when the measurements are performed in the 8–14 μm atmospheric window.
A comparison of direct and indirect methods for measuring leaf and surface areas of individual bushes
1995
Indirect estimates of leaf area from measurements with three commercially available instruments (DEMON, LAI-2000 and Sunfleck Ceptometer) were compared with directly measured areas of individual Retama sphaerocarpa bushes. The three indirect methods gave good estimates of the total surface area of individual bushes. For the DEMON, the method of log-linear averaging of transmitted radiation gave estimates closer to directly measured surface area than the method of averaging transmission linearly. For the LAI-2000, estimated surface area index multiplied by canopy projected area gave the best agreement with directly measured values. For measurements with the Sunfleck Ceptometer, values of sur…
Luminescence of the surface nonbridging oxygen hole center in silica: Spectral and decay properties
2008
We investigated the red luminescence in a porous film of silica nanoparticles, originating from surface nonbridging oxygen hole centers. The excitation spectrum was measured from 1.8 to 8.0 eV by a tunable laser system and a synchrotron radiation source; this spectrum evidences a peak at 2.0 eV, nearly overlapping with the emission, and an ultraviolet broadband with peaks at 4.8 and 6.0 eV. The emission is characterized by a spectrum with two subbands split by 0.07 eV, its decay occurs with lifetime longer than 30 microsec and undergoes a thermal quenching by a factor aboout 2 with increasing temperature from 10 to 290 K. The optical characteristics of surface and bulk centers are discussed…
Measuring Multiple Residual-Stress Components using the Contour Method and Multiple Cuts
2009
The conventional contour method determines one component of residual stress over the cross section of a part. The part is cut into two, the contour (topographic shape) of the exposed surface is measured, and Bueckner’s superposition principle is analytically applied to calculate stresses. In this paper, the contour method is extended to the measurement of multiple residual-stress components by making multiple cuts with subsequent applications of superposition. The theory and limitations are described. The theory is experimentally tested on a 316L stainless steel disk with residual stresses induced by plastically indenting the central portion of the disk. The multiple-cut contour method resu…
Systematic Error Correction of a 3D Laser Scanning Measurement Device
2011
International audience; Non-contact measurement techniques using laser scanning have the advantage of fast acquiring large numbers of points. However, compared to their contact-based counterparts, these techniques are known to be less accurate. The work presented in this paper aims at improving the accuracy of these techniques through an error correction procedure based on an experimental process that concerns mechanical parts. The influence of the three parameters defining the relative position and the orientation between the sensor and the surface is studied. The process used to build an experimental global model of error is presented and applied to a typical part composed of planes or sk…
Assessment of particle suspension conditions in stirred vessels by means of pressure gauge technique
2002
In this work the quantitative assessment of the mass of suspended solid particles in stirred vessels is performed using the Pressure Gauge Technique. This is based on the measurements of the pressure increase on the tank bottom due to the presence of suspended solid particles at any agitation speed. The method has the advantages of not utilising visual observations and of easy and inexpensive application to both laboratory and industrial equipment. Very few data are available in literature and the experimental results collected using the present PGT technique and the correlations here proposed are of considerable academic and industrial interest.
Sustainable Development Goals and Performance Measurement of Positive Energy District: A Methodological Approach
2021
The “Positive Energy Districts and Neighbourhoods for Sustainable Urban Development” program launched by the European Union can be considered a milestone towards the clean energy transition and carbon neutrality of urban areas. The achievement of this ambitious transition requires properly defined methodologies and action plans grounded on the main environmental, economic, and social pillars of sustainability. This paper is focused on the definition of a methodology for the characterization of PEDs sustainability assessment in terms of Sustainable Development Goals. In particular, the main research question to be answered regards the allocation of the surplus energy of PEDs to target the su…
Quantification of Lung Volume at Different Tidal Volumes and Positive End-Expiratory Pressures in a Porcine Model by Using Retrospective Respiratory …
2008
PURPOSE: This feasibility study in healthy animals should prove the concept that it is possible to quantitatively assess the effects of different ventilatory settings on the lung parenchyma during ongoing ventilation in respiratory gated 4-dimensional (D)-computed tomography (CT). For this purpose, the influence of different tidal volumes and positive end-expiratory pressure (PEEP) on quantitative assessment of lung volumes (LVs) and lung compartments was analyzed. METHODS: Five anesthetized and ventilated (20 breaths/min, inspiratory/expiratory ratio of 1:2) healthy pigs underwent 16-row multidetector CT with retrospective respiratory gating using a noncontact charge-coupled device camera …