Search results for "Measurement"
showing 10 items of 2918 documents
Noiseless Quantum Measurement and Squeezing of Microwave Fields Utilizing Mechanical Vibrations
2017
A process which strongly amplifies both quadrature amplitudes of an oscillatory signal necessarily adds noise. Alternatively, if the information in one quadrature is lost in phase-sensitive amplification, it is possible to completely reconstruct the other quadrature. Here we demonstrate such a nearly perfect phase-sensitive measurement using a cavity optomechanical scheme, characterized by an extremely small noise less than 0.2 quanta. We also observe microwave radiation strongly squeezed by 8 dB below vacuum. A source of bright squeezed microwaves opens up applications in manipulations of quantum systems, and noiseless amplification can be used even at modest cryogenic temperatures.
Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments
2021
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and volume-averaged root-mean-square normal noise amplitudes at a certain frequency bandwidth for a cylindrical geometry. In addition, we model the source of noise as a finite number of current dipoles and demonstrate a method to simulate temporal and three-dimensional spatial dependencies of JNN. The c…
Mass measurements of As, Se, and Br nuclei, and their implication on the proton-neutron interaction strength toward the N=Z line
2021
Mass measurements of the $^{69}$As, $^{70,71}$Se and $^{71}$Br isotopes, produced via fragmentation of a $^{124}$Xe primary beam at the FRS at GSI, have been performed with the multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) of the FRS Ion Catcher with an unprecedented mass resolving power of almost 1,000,000. For the $^{69}$As isotope, this is the first direct mass measurement. A mass uncertainty of 22 keV was achieved with only 10 events. For the $^{70}$Se isotope, a mass uncertainty of 2.6 keV was obtained, corresponding to a relative accuracy of $\delta$m/m = 4.0$\times 10^{-8}$, with less than 500 events. The masses of the $^{71}$Se and $^{71}$Br isotopes were measured…
Mass measurements of neutron-deficient nuclei and their implications for astrophysics
2012
During the years 2005-2010 the double-Penning-trap mass spectrometer JYFLTRAP has been used to measure the masses of 90 ground and 8 isomeric states of neutron-deficient nuclides with a typical precision of better than 10keV. The masses of 14 nuclides -- 84Zr , 88, 89Tc , 90-92Ru , 92-94Rh , 94, 95Pd , 106, 108, 110Sb -- have been experimentally determined for the first time. This article gives an overview on these measurements and their impact on the modeling of the astrophysical rp -process. peerReviewed
Teachers' self-efficacy and the sources of efficacy: A cross-cultural investigation in Japan and Finland
2019
The study explores the extent and sources of Teachers’ Self-Efficacy (TSE) for inclusive practices among 261 Japanese and 1123 Finnish teachers. Measurement invariance was tested to ensure the chosen scales’ cross-cultural validity. In both countries, mastery experience was identified as the strongest of the four sources contributing uniquely to TSE. However, the two groups differed in how verbal persuasion predicted TSE. The findings indicate that the effects of the four sources on TSE depend strongly on sociocultural context, and that, in Japan, other sources may exert a powerful influence. Practical implications are discussed, with particular regard to teacher training programs. peerRevi…
Effects of school-based physical activity on mathematics performance in children: a systematic review
2019
AbstractBackgroundThe benefits of physical activity (PA) on children’s health and wellbeing are well established. However, the benefits of PA on academic performance and particularly on mathematics performance warrant systematic analysis. Mathematics is one of the core subjects in school education globally.MethodsWe systematically searched, analysed and synthesized the literature on the effects of school-based PA interventions on mathematics performance in children aged 4–16. A total of 29 studies consisting of randomised trials and other interventions with control groups were identified through a systematic search, and 11 of them provided sufficient data and appropriate design for a meta-a…
On-Line Characterization of Gamma Radiation Effects on Single-Ended Raman Based Distributed Fiber Optic Sensor
2016
We report distributed temperature measurements based on Raman scattering performed during steady state $\gamma $ -ray irradiation at a dose rate of 1 kGy( ${\rm SiO}_{2}$ )/h and up to a total ionizing dose (TID) of $\sim 0.1\ \hbox{MGy}$ . We characterize on-line the evolution of the performances of a single-ended Raman distributed temperature sensor (RDTS) during the $\gamma $ -ray exposure of different classes of commercial multimode fibers (MMFs) acting as the sensing element. RDTS is influenced by the radiation-induced attenuation (RIA) phenomena leading to both large errors in the temperature measurements and a diminution of the useful sensing length. The amplitude of the radiation-in…
Investigation of Coating Impact on OFDR Optical Remote Fiber-Based Sensors Performances for Their Integration in High Temperature and Radiation Envir…
2016
The response of optical frequency-domain reflectometry-based temperature sensors is here investigated in harsh environments (high temperature, high radiation dose) focusing the attention on the impact of the fiber coating on the sensor performances in such conditions. Our results demonstrate that the various coating types evolve differently under thermal treatment and/or radiations, resulting in a small (<5%) change in the temperature coefficient of the sensor. The identified procedure, consisting of a prethermal treatment of the fiber at its maximum coating operating temperature, is here verified up to 150 °C for higherature acrylate and up to 300 °C for polyamide coating. This method allo…
Measurement of the soliton number in guiding media through continuum generation.
2020
No general approach is available yet to measure directly the ratio between chromatic dispersion and the nonlinear coefficient, and hence the soliton number for a given optical pulse, in an arbitrary guiding medium. Here we solve this problem using continuum generation. We experimentally demonstrate our method in polarization-maintaining and single-mode fibers with positive and negative chromatic dispersion. Our technique also offers new opportunities to determine the chromatic dispersion of guiding media over a broad spectral range while pumping at a fixed wavelength. (C) 2020 Optical Society of America
Structural Parameters under Partial Least Squares and Covariance-Based Structural Equation Modeling : A Comment on Yuan and Deng (2021)
2023
In their article, Yuan and Deng argue that a structural parameter under partial least squares structural equation modeling (PLS-SEM) is zero if and only if the same structural parameter is zero under covariance-based structural equation modeling (CB-SEM). Yuan and Deng then conclude that statistical tests on individual structural parameters assessing the null hypothesis of no effect can achieve the same purpose in CB-SEM and PLS-SEM. Our response to their article highlights that the relationship they find between PLS-SEM and CB-SEM structural parameters is not universally valid, and that consequently, tests on individual parameters in CB-SEM and PLS-SEM generally do not fulfill the same pur…