New Stage-Discharge Equation for the SMBF Flume
2016
AbstractFlumes for indirect discharge measurements are widespread and are characterized by a particular shape of the cross section area with various degrees of convergence and subsequent divergence. The flume named Samani, Magallanez, Baiamonte, Ferro (SMBF) is a simple and inexpensive instrument and its channel contraction is obtained by applying two semicylinders to the walls of a rectangular cross section. At first, in this paper a new stage-discharge equation for the SMBF flume is theoretically deduced. Then, this equation is experimentally calibrated using the laboratory measurements from the literature for different values of the contraction ratio. Finally the field measurements carri…
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
An Innovative Measurement Approach for Load Flow Analysis in MV Smart Grids
2016
This paper proposes a novel measurement procedure for load flow analysis in medium voltage (MV) smart grids. The new approach is based on power measurements at low voltage (LV) side of MV/LV distribution substations. Such measurements are carried out by means of power quality analyzers. If compared with the load flow methods based on measurements at the MV side, the proposed approach has a lower cost and it offers an equally reliable measurement system. The proposed algorithm takes the basic concept of the current summation backward/forward method; some modifications are introduced to use LV load powers measurements. To this aim, the MV/LV power transformer is properly modeled and taken int…
A New Low Cost Coupling System for Power Line Communication on Medium Voltage Smart Grids
2018
This paper proposes and verifies the performance of an innovative and low cost coupling system for power line communication (PLC) on medium voltage (MV) smart grids. The coupling system makes use of the capacitive divider of the voltage detecting systems (VDSs) to inject and receive the PLC signal. VDS are usually already installed in the MV switchboards of the major electrical manufacturer all over the world according to IEC 61243-5. VDS are used to detect the presence of the mains voltage to guarantee personnel safety. An interface circuit has been developed to be connected between the PLC transceiver and the VDS socket. In this way, the PLC signal can be coupled to the MV network without…
Low-cost underwater navigation systems by multi-pressure measurements and AHRS data
2017
This paper deals with accurate navigation for underwater remotely operated vehicles. A feasibility study for a multi-pressure device to be mounted on an ROV is presented. The device can provide accurate estimates of a ROV orientation and angular speed. It is based on the well-known total pressure principle, also used in a Pitot tube, and allows reconstruction of static and dynamic pressures, which in turn provide good estimates of the ROV's orientation and rotational speed, respectively. An appealing feature of the proposed device is its ability to provide accurate estimates even for low-speed movements.
Synchronization techniques for power quality instruments
2004
The measurement of voltage characteristics in power systems requires the accurate estimation of the power supply frequency and signal synchronization, even in the presence of disturbances. The authors developed and tested two innovative techniques for instrument synchronization. The first is based on signal spectral analysis techniques performed by means of the Chirp-Z transform analysis. The second is a phase-locked loop (PLL) software based on a time-domain coordinate transformation and an innovative phase-detection technique. To evaluate how synchronization techniques are adversely affected by the application of a disturbing influence, experimental tests were carried out, taking into acc…
Wideband modeling of cascaded H-plane waveguide junctions using the generalised impedance matrix representation
2009
A strong interest in H-plane waveguide components composed of a large number of cascaded planar junctions is recently renewed. Therefore, the more efficient development of full-wave analysis tools of such devices is again receiving consideration, specially for its potential use within modern design tools. A novel technique for providing the wideband generalised impedance matrix representation of the inductive devices in the form of pole expansions, thus extracting the most expensive computations from the frequency loop is proposed. For such purpose, the whole device is first decomposed into simpler building blocks, i.e. planar junctions and uniform waveguides, which are modelled in terms of…
New Measurement Procedure for Load Flow Evaluation in Medium Voltage Smart Grids
2013
The aim of this paper is to present a new approach for the medium voltage (MV) distribution network load flow analysis, mainly based on power measurement at the low voltage (LV) level of MV/LV distribution substations. This allows to use measurement instruments, usually already installed in the secondary substations, thus achieving an equally reliable measurement system with a lower cost compared to measurements at the MV side. The new approach can be applied using a proper communication system to collect the nodal measurements and an iterative algorithm based on ladder iterative technique (LIT) to compute the load flow. The validity of this method is presented and discussed on the basis of…
Applicational Aspects of a New Diagnostic Methodology for Fault Location in MV Networks: Problems, Solutions and Improvements
2005
The electrical energy market liberalization has encouraged utilities to make new investments at distribution level so as to attain higher quality levels. Service continuity is one of the aspects of greater importance in the definition of the quality of the electrical energy, for this reason, the research in the field of faults diagnostic for distribution systems is spreading ever more. The Authors have just developed a new methodology for diagnostic management of automated distribution systems. The technique is based on the use of circuital models of the electrical system resulting from the composition of quadripoles. In this paper, after a brief description of the proposed approach, the is…
Mono and Stereoscopic Image Analysis for Detecting the Transverse Profile of Worn-Out Rails
2012
AbstractThe purpose of this paper is to suggest a new procedure for reconstructing the transverse profile of rails in operation by means of image-processing technique. This methodological approach is based on the “information” contained in high-resolution photographic images of tracks and on specific algorithms which allow to obtain the exact geometric profile of the rails and therefore to measure the state of the rail-head extrados wear. The analyses and the results concern rails taken from railway lines under upgrading by means of mono- and stereoscopic methods which are appropriate to be employed in laboratory applications or in high-efficiency surveys in situ.