Search results for "Measurements"
showing 10 items of 720 documents
Chlorine partitioning in the lowermost Arctic vortex during the cold winter 2015/2016
2019
Activated chlorine compounds in the polar winter stratosphere drive catalytic cycles that deplete ozone and methane, whose abundances are highly relevant to the evolution of global climate. The present work introduces a novel dataset of in situ measurements of relevant chlorine species in the lowermost Arctic stratosphere from the aircraft mission POLSTRACC–GW-LCYCLE–SALSA during winter 2015/2016. The major stages of chemical evolution of the lower polar vortex are presented in a consistent series of high-resolution mass spectrometric observations of HCl and ClONO2. Simultaneous measurements of CFC-12 are used to derive total inorganic chlorine (Cly) and active chlorine (ClOx). The new data…
A battery of toxicity tests as indicators of decontamination in composting oily waste.
2000
Heterogeneous oily waste from an old dumping site was composted in three windrows constructed from different proportions of waste, sewage sludge, and bark. The objectives of this pilot study were to examine the usefulness of composting as a treatment method for this particular waste and to study decontamination in the composting process by using a battery of toxicity tests. Five samples from the windrow having intermediate oil concentrations were tested with toxicity tests based on microbes (Pseudomonas putida growth inhibition test, ToxiChromotest, MetPLATE, and three different modifications of a luminescent bacterial test), enzyme inhibition (reverse electron transport), plants (duckweed …
Sun-induced fluorescence - a new probe of photosynthesis: First maps from the imaging spectrometer HyPlant.
2015
Variations in photosynthesis still cause substantial uncertainties in predicting photosynthetic CO2 uptake rates and monitoring plant stress. Changes in actual photosynthesis that are not related to greenness of vegetation are difficult to measure by reflectance based optical remote sensing techniques. Several activities are underway to evaluate the sun-induced fluorescence signal on the ground and on a coarse spatial scale using space-borne imaging spectrometers. Intermediate-scale observations using airborne-based imaging spectroscopy, which are critical to bridge the existing gap between small-scale field studies and global observations, are still insufficient. Here we present the first …
A New Simple Static Method for the Determination of Solubilities of Condensed Compounds in Supercritical Fluids
2002
Abstract A simple static method based on gravimetric measurements has been adopted to measure the solubility of benzenecarboxylic acid, 2-hydroxy-benzenecarboxylic acid, 4-hydroxy-benzenecarboxylic acid and 1,8-dihydroxyanthraquinone along several isotherms in the temperature range 318–357 K and the pressure interval 7–23 MPa. Solubility data have been correlated with the Zieger–Eckert approach, using the Fedor atomic and group contribution method to estimate the solubility parameter and the molar volume of the solutes. A good agreement was obtained between data reported in the literature and those determined using the proposed method which allows one to measure solubility mole fraction as …
Effects of ultrahigh dilutions of 3,5-dichlorophenol on the luminescence of the bacterium Vibrio fischeri.
2003
Abstract There is a great need for research in the field of homeopathy for laboratory test systems to investigate the actions of ultrahighly diluted biological effectors. With this in mind, we used the luminescent bacterium Vibrio fischeri, which is used throughout the world in testing water quality. Luminescence inhibition is utilized as a test parameter for the toxicity of a sample. We used ultrahigh dilutions (UHD) of 3,5-dichlorophenol as effector and adapted the standard test procedure for water toxicity in a way that let us evaluate very minute effects. Three groups of samples were prepared and then blinded: 45 dilutions of 3,5-dichlorophenol in steps of 10, starting with 4.2×10−2 M, …
Strong circularly polarized luminescence of an octahedral chromium(iii) complex
2019
The chiral spin-flip luminophore [Cr(ddpd)2]3+ can be resolved into enantiopure material by chiral HPLC. The corresponding enantiomers show very high luminescence dissymmetry factors of up to ∣glum ∣≈ 0.093 in circularly polarized luminescence (CPL) measurements for the "ruby-like" phosphorescence transition 2E/2T1 → 4A2 in the near-IR region around λ ≈ 775 nm.
Dynamics of mild strombolian activity on Mt. Etna
2015
Abstract Here we report the first measurements of gas masses released during a rare period of strombolian activity at the Bocca Nuova crater, Mt. Etna, Sicily. UV camera data acquired for 195 events over an ≈ 27 minute period (27th July 2012) indicate erupted SO2 masses ranging from ≈ 0.1 to ≈ 14 kg per event, with corresponding total gas masses of ≈ 0.1 to 74 kg. Thus, the activity was characterised by more frequent and smaller events than typically associated with strombolian activity on volcanoes such as Stromboli. Events releasing larger measured gas masses were followed by relatively long repose periods before the following burst, a feature not previously reported on from gas measureme…
A modified applicative criterion of the physical model concept for evaluating plot soil erosion predictions
2015
Abstract In this paper, the physical model concept by Nearing (1998. Catena 32: 15–22) was assessed. Soil loss data collected on plots of different widths (2–8 m), lengths (11–44 m) and steepnesses (14.9–26.0%), equipped in south and central Italy, were used. Differences in width between plots of given length and steepness determined a lower data correlation and more deviation of the fitted regression line from the identity one. A coefficient of determination between measured, M , and predicted, P , soil losses of 0.77 was representative of the best-case prediction scenario, according to Nearing (1998). The relative differences, Rdiff = ( P − M ) / ( P + M ), decreased in absolute value a…
Colour Specification of Terracotta Calatina Specimens
2012
A new low cost power line communication solution for smart grid monitoring and management
2018
Modern smart grids require the improvement of measurement and communication infrastructures of distribution networks, at both medium voltage (MV) and low voltage (LV) levels. Distributed sensing and measurement systems are needed to provide all necessary data for grid monitoring, control and management, as well as for the implementation of a number of smart functionalities, such as remote control of distributed generators (DGs), real time analysis of power flows, automatic meter reading (AMR), demand side management (DSM), grid automation and so on [1]-[6]. Acquired network data include typical electrical network quantities and status variables (such as powers, voltages, currents, switches …