Search results for "Measurements"
showing 10 items of 720 documents
A systematic review of maternal smoking during pregnancy and fetal measurements with meta-analysis
2017
Maternal smoking during pregnancy is linked to reduced birth weight but the gestation at onset of this relationship is not certain. We present a systematic review of the literature describing associations between maternal smoking during pregnancy and ultrasound measurements of fetal size, together with an accompanying meta-analysis. Studies were selected from electronic databases (OVID, EMBASE and Google Scholar) that examined associations between maternal smoking or smoke exposure and antenatal fetal ultrasound measurements. Outcome measures were first, second or third trimester fetal measurements. There were 284 abstracts identified, 16 papers were included in the review and the meta-anal…
LV Measurement Device Placement for Load Flow Analysis in MV Smart Grids
2016
This paper deals with the issue of measurement device placement for load flow analysis in medium-voltage (MV) distribution networks. The study is carried out using an innovative measurement algorithm for load flow analysis developed by the authors. It is based on low-voltage (LV) load power measurements applied on a backward/forward algorithm for the load flow resolution. The final aim is to identify the most suitable number and placement of the LV measurement points in order to limit the uncertainty on the power flow estimation to a target value. The proposed approach is based on the uncertainty evaluation of the estimated power flows; a sensitivity analysis is performed in order to assess…
A set of indicators for arc faults detection based on low frequency harmonic analysis
2016
In this paper a novel set of indicators is presented for arc faults detection in electrical circuits. The indicators are defined starting from an experimental characterization of the arc fault phenomenon and the study of the arcing current in several test conditions, which were chosen in accordance with the UL 1699 Standard requirements. The proposed parameters are measured by means of a high resolution low frequency spectral analysis of the arcing current, which allows to achieve a good spectral resolution even with short observation windows.
Measurements and Observations in the XXI century (MOXXI) : innovation and multi-disciplinarity to sense the hydrological cycle
2018
ISI Document Delivery No.: FV7JXTimes Cited: 4Cited Reference Count: 249Tauro, Flavia Selker, John van de Giesen, Nick Abrate, Tommaso Uijlenhoet, Remko Porfiri, Maurizio Manfreda, Salvatore Caylor, Kelly Moramarco, Tommaso Benveniste, Jerome Ciraolo, Giuseppe Estes, Lyndon Domeneghetti, Alessio Perks, Matthew T. Corbari, Chiara Rabiei, Ehsan Ravazzani, Giovanni Bogena, Heye Harfouche, Antoine Brocca, Luca Maltese, Antonino Wickert, Andy Tarpanelli, Angelica Good, Stephen Alcala, Jose Manuel Lopez Petroselli, Andrea Cudennec, Christophe Blume, Theresa Hut, Rolf Grimaldi, SalvatoreTaylor & francis ltdAbingdon; To promote the advancement of novel observation techniques that may lead to new so…
Energy measurements at Skarpnes zero energy homes in Southern Norway: Do the loads match up with the on-site energy production?
2017
Five houses are designed as zero-energy homes in Skarpnes, Norway. The energy goal is to achieve net zero-energy balance on an annual basis. The houses have heat pumps and solar cells (PV). Energy use and delivered energy have been monitored from June 2015. Variations between calculations and measurements are explained by technical and non-technical reasons. For the first year, higher than expected energy loads result in a solar energy cover factor of 65–87% of delivered electricity. The PV generation performs satisfactorily, hence, it may be possible to achieve energy goals during later years provided technical adjustments or behavioral changes. Acknowledgements. This report has been writt…
Modular, customisable, accomodation-friendly antenna system for satellite avionics: Development, prototyping and validation
2014
In the frame of ESA program AO/1- 6737/11/NL/MH, an innovative X-band antenna system for satellite avionics has been studied, demonstrated and validated at Proof of Concept Model level. The innovative contribution of such an antenna system relies on modularity, customizability and accommodation friendliness. The antenna concept is based on a Plug and Play architecture, where the basic module is a 2.7 cm-cube with a mass of 53 gr, which can be clustered in array configuration. A catalogue of predefined and ready-to-use clusters could be developed with the possibility of adapting the antenna systems to various platform types by tuning just a few control parameters. Different levels of customi…
A simplified approach for load flow analysis in MV smart grids based on LV power measurements
2017
This paper presents a simplified approach for load flow analysis in medium voltage (MV) distribution networks. It is a power summation Backward/Forward (B/F) algorithm, based on measurements of active and reactive powers at low voltage (LV) side of MV/LV distribution substations. The proposed solution allows achieving good accuracy, computational efficiency and fast convergence. In order to verify the algorithm performances, simulation studies are carried out in the case of a real test system, i.e. the distribution grid of Favignana Island (Mediterranean Sea, Italy). The compatibility between simulations results and power measurements at the MV bus bars of the generating substation shows th…
Quasi-digital conversion for resistive devices: application in GMR-based IC current sensors
2013
Resistive devices, including sensors, are used in a huge range of applications within different scenarios. When a complete system is considered, a quasi-digital output is often recommendable. If the conversion is operated at device level, some problems such as noise disturbs, insertion losses and so on, can be reduced. In this work, we describe a resistance-tofrequency (R-f) converter with a suggested application in low current monitoring by means of GiantMagnetoResistance (GMR) sensors. Specific devices have been designed and microfabricated. The system has been tested by means of discrete components with a PCB. The complete microsystem monolithic integration in a standard CMOS technology …
A PC-based wattmeter for high accuracy power measurements
2010
This paper proposes the use of a commercial data acquisition board (DAQ) connected to a common personal computer for high accuracy power measurements. In the paper the set up of the PC-based wattmeter is described and an experimental evaluation of its metrological performances is made by means of the comparison with a simultaneous coherent digital sampling wattmeter realized with two high-precision DMMs Hewlett Packard Model 3458 A. In both cases the power source is a Fluke 6100A/E electrical power standard. © 2010 IEEE.
Field Testing of a Simple Flume (SMBF) for Flow Measurement in Open Channels
2008
In this paper the stage–discharge relationship of a new flume named SMBF (Samani, Magallanex, Baiamonte, Ferro), originally proposed by Samani and Magallanez and tested by Baiamonte and Ferro, for measuring flow discharge in open channels is reviewed. The flume is obtained inserting two semicylinders in a rectangular cross section. The results of some experimental runs carried out using horizontal flumes characterized by different values of the contraction ratio (ranging from 0.17 to 0.81) are used for determining the two coefficients of the power stage–discharge equation. The stage–discharge equation is tested using flow measurements carried out in the period between December 2004 and Marc…