Search results for "Measurements"

showing 10 items of 720 documents

Hyper-concentrated flow and surface velocity estimation by digital imaging technique: a study case

2015

This paper investigates the utility of digital imaging technique for performing surface velocity measurements of hyper-concentrated flows. The analysis is conducted with the aid of data collected in a scale laboratory flume constructed at the Hydraulic laboratory of the Department of Civil, Environmental, Aerospatial and of Materials Engineering (DICAM) – University of Palermo (Italy). In particular the present paper describes the setup of a laboratory test and the applicability of a fully digital imaging approach.

Predictions hyper-concentrated flows flow velocity experiments digital measurementsSettore ICAR/01 - Idraulica
researchProduct

Defect incorporation in In-containing layers and quantum wells: Experimental analysis via deep level profiling and optical spectroscopy

2020

Abstract Recent studies demonstrated that the performance of InGaN/GaN quantum well (QW) light emitting diodes (LEDs) can be significantly improved through the insertion of an InGaN underlayer (UL). The current working hypothesis is that the presence of the UL reduces the density of non-radiative recombination centers (NRCs) in the QW itself: during the growth of the UL, surface defects are effectively buried in the UL, without propagating towards the QW region. Despite the importance of this hypothesis, the concentration profile of defects in the quantum wells of LEDs with and without the UL was never investigated in detail. This paper uses combined capacitance-voltage and steady-state pho…

Profiling (computer programming)Materials scienceAcoustics and UltrasonicsDeep levelInGaNbusiness.industryunderlayerSSPC measurementsCondensed Matter PhysicsSettore ING-INF/01 - ElettronicaSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialsdefects growthefficiencyOptoelectronicsSpectroscopybusinessdefects growth; InGaN; SSPC measurements; underlayerperformanceQuantum well
researchProduct

Teaching mechanical oscillations using an integrate curriculum

1997

Abstract A set of teaching materials dealing with harmonic oscillations was developed as part of a research project investigating the influence of different pedagogical tools on physics learning. The materials incorporate simulation software and laboratory activities associated with Teacher and Student Units. The project involved research groups at seven Italian universities and the materials have been trialled in high schools nation‐wide. This paper describes the experimental protocol for the use of these materials in pilot classes and the evaluation of student learning and teacher training results. The intervention was found to improve physics education at school praxis level and to promo…

Protocol (science)Sociology of scientific knowledgePraxisContent areaLaboriatorymedia_common.quotation_subjectPhysics educationOn-line measurementsinnovative apprachesIntegrated curriculumcomputer.software_genreEducationSimulation softwarePhysics EducationSeven Italian universities coordinationMechanical OscillationsPhysics Education; Mechanical Oscillations; Laboriatory; On-line measurementsComputingMilieux_COMPUTERSANDEDUCATIONMathematics educationstudents difficultieSet (psychology)computermedia_common
researchProduct

Los bancos de items en el desarrollo de tests : aspectos psicométricos y análisis de un sistema para su desarrollo y gestión informatizada

1997

Psychology Psychometrics:PSICOLOGÍA [UNESCO]UNESCO::PSICOLOGÍAEducation Tests and Measurements
researchProduct

Production of reactive oxygen intermediates by human macrophages exposed to soot particles and asbestos fibers and increase in NF-kappa B p50/p105 mR…

1999

Alveolar macrophages (AM) play a decisive role in the immunologic defense system of the lung and in inflammatory pulmonary pathomechanisms. AM and blood monocytes (BM) were exposed to chrysotile B, soot FR 101, and Printex 90 (P 90). We evaluated the reactive oxygen intermediate (ROI) release of AM and BM after particle exposure. ROI release was measured by chemiluminescence. Thirty-minute exposure caused a significant (up to 2.5-fold) increase in ROI release of AM (100 micrograms/10(6) cells) compared with control experiments (p0.01). Identical exposure conditions for BM resulted in a similar reaction pattern (maximum 2.2-fold increase in ROI release; p0.05). After a 90-min particle exposu…

Pulmonary and Respiratory MedicineAdultMaleP50Asbestos Serpentinemedicine.medical_treatmentMonocytesProinflammatory cytokineSuperoxide dismutaseGene expressionMacrophages AlveolarmedicineHumansRNA MessengerReceptorCells CulturedAgedLungbiologyDose-Response Relationship DrugChemistryReverse Transcriptase Polymerase Chain ReactionNF-kappa BMiddle AgedNFKB1Molecular biologyCarbonCytokinemedicine.anatomical_structureGene Expression RegulationImmunologyLuminescent Measurementsbiology.proteinFemaleReactive Oxygen SpeciesBronchoalveolar Lavage FluidLung
researchProduct

Airway distensibility by HRCT in asthmatics and COPD with comparable airway obstruction.

2013

Introduction: Decreased airway distensibility (AD) in response to deep inspirations, as assessed by HRCT, has been associated with the severity of asthma and COPD. Aims: The current study was designed to compare the magnitude of AD by HRCT in individuals with asthma and COPD with comparable degrees of bronchial obstruction, and to explore factors that may influence it. Results: We enrolled a total of 12 asthmatics (M/F:7/5) and 8 COPD (7/1) with comparable degree of bronchial obstruction (FEV1% predicted mean±SEM: 69.1 ± 5.2% and 61.2 ± 5.0%, respectively; p = 0.31). Each subject underwent chest HRCT at FRC and at TLC. A total of 701 airways (range 20 to 38 airway per subject; 2.0 to 23.1 m…

Pulmonary and Respiratory MedicineAdultMalemedicine.medical_specialtyVital CapacityLung Volume MeasurementSettore MED/10 - Malattie Dell'Apparato RespiratorioImagingDeep inspirationPulmonary Disease Chronic ObstructiveInternal medicineForced Expiratory VolumeMultidetector Computed TomographyMedicineHumansLung volumesBronchial obstructionLungAsthmaAgedCOPDbusiness.industryrespiratory systemAirway obstructionMiddle Agedmedicine.diseaseAsthmarespiratory tract diseasesLung volumeAirway distensibility Asthma COPDSpirometryCardiologyFemaleRadiologyAirwaybusinessLung Volume MeasurementsHumanCOPD
researchProduct

Effect of unilateral diaphragmatic paralysis on postpneumonectomy lung growth.

2013

Respiratory muscle-associated stretch has been implicated in normal lung development (fetal breathing movements) and postpneumonectomy lung growth. To test the hypothesis that mechanical stretch from diaphragmatic contraction contributes to lung growth, we performed left phrenic nerve transections (PNT) in mice with and without ipsilateral pneumonectomy. PNT was demonstrated by asymmetric costal margin excursion and confirmed at autopsy. In mice with two lungs, PNT was associated with a decrease in ipsilateral lung volume ( P < 0.05) and lung weight ( P < 0.05). After pneumonectomy, PNT was not associated with a change in activity level, measureable hypoxemia, or altered minute venti…

Pulmonary and Respiratory MedicinePhysiologymedicine.medical_treatmentDiaphragmDiaphragmatic breathingDiaphragmatic paralysisPneumonectomyMicePhysiology (medical)MedicineAnimalsLung volumesRespiratory systemPneumonectomyLungPhrenic nerveLungbusiness.industryRespirationCell BiologyArticlesrespiratory systemRespiratory ParalysisDiaphragm (structural system)respiratory tract diseasesPhrenic Nervemedicine.anatomical_structureAnesthesiabusinessLung Volume MeasurementsAmerican journal of physiology. Lung cellular and molecular physiology
researchProduct

Lung Function Monitoring; A Randomized Agreement Study

2016

Objective: To determine the agreement between devices and repeatability within devices of the forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), peak expiratory flow (PEF) and forced expiratory flow at 50% of FVC (FEF50) values measured using the four spirometers included in the study. Methods: 50 (24 women) participants (20-64 years of age) completed maximum forced expiratory flow manoeuvres and measurements were performed using the following devices: MasterScreen, SensorMedics, Oxycon Pro and SpiroUSB. The order of the instruments tested was randomized and blinded for both the participants and the technicians. Re-testing was conducted on a following day within 72 hours …

Pulmonary and Respiratory Medicinemedicine.medical_specialtyVital capacitySpirometersTestingArticleMean difference03 medical and health sciencesFEV1/FVC ratio0302 clinical medicineInternal medicinemedicineAdultsRepeatability030212 general & internal medicineLung functionReproducibilitybusiness.industryMeasurementsRepeatabilityrespiratory systemReproducibilityConfidence intervalrespiratory tract diseases030228 respiratory systemPhysical therapyCardiologybusinessThe Open Respiratory Medicine Journal
researchProduct

Mechanostructural adaptations preceding postpneumonectomy lung growth

2012

In many species, pneumonectomy results in compensatory growth in the remaining lung. Although the late mechanical consequences of murine pneumonectomy are known, little is known about the anatomic adaptations and respiratory mechanics during compensatory lung growth. To investigate the structural and mechanical changes during compensatory growth, mice were studied for 21 days after left pneumonectomy using microCT and respiratory system impedance (FlexiVent). Anatomic changes after left pneumonectomy included minimal mediastinal shift or chestwall remodeling, but significant displacement of the heart and cardiac lobe. Mean displacement of the cardiac lobe centroid was 5.2 ± 0.8 mm. Lung imp…

Pulmonary and Respiratory Medicinemedicine.medical_specialtymedicine.medical_treatmentHysteresivityClinical BiochemistryMediastinal ShiftRespiratory physiologyPulmonary complianceBiologyArticleMicePneumonectomyInternal medicineRespirationmedicineAnimalsRegenerationPostoperative PeriodRespiratory systemPneumonectomyThoracic WallLungLung ComplianceMolecular BiologyLungRespirationElectric ConductivityOrgan SizeX-Ray MicrotomographyAnatomyAdaptation PhysiologicalElasticityMice Inbred C57BLDisease Models Animalmedicine.anatomical_structureCardiologyLung Volume MeasurementsExperimental Lung Research
researchProduct

Dynamic determination of oxygenation and lung compliance in murine pneumonectomy.

2011

Thoracic surgical procedures in mice have been applied to a wide range of investigations, but little is known about the murine physiologic response to pulmonary surgery. Using continuous arterial oximetry monitoring and the FlexiVent murine ventilator, the authors investigated the effect of anesthesia and pneumonectomy on mouse oxygen saturation and lung mechanics. Sedation resulted in a dose-dependent decline of oxygen saturation that ranged from 55% to 82%. Oxygen saturation was restored by mechanical ventilation with increased rate and tidal volumes. In the mouse strain studied, optimal ventilatory rates were a rate of 200/minute and a tidal volume of 10 mL/kg. Sustained inflation pressu…

Pulmonary and Respiratory Medicinemedicine.medical_treatmentClinical BiochemistryPulmonary complianceArticlePositive-Pressure RespirationPneumonectomyMiceTidal VolumeMedicineAnimalsLung volumesAnesthesiaPneumonectomyMolecular BiologyLungLung ComplianceTidal volumeOxygen saturation (medicine)Mechanical ventilationLungbusiness.industryTotal Lung CapacityOxygenationrespiratory systemRespiration ArtificialMice Inbred C57BLOxygenmedicine.anatomical_structureAnesthesiabusinessLung Volume MeasurementsExperimental lung research
researchProduct