Search results for "Mechanical Phenomena"

showing 10 items of 532 documents

Biomechanical effectiveness of a distraction-rotation knee brace in medial knee osteoarthritis: preliminary results.

2013

Abstract Background Non-pharmacological therapies are recommended for the care of knee osteoarthritis patients. Unloader knee braces provide an interesting functional approach, which aims to modulate mechanical stress on the symptomatic joint compartment. We aimed to confirm the biomechanical effects and evaluate functional benefits of a new knee brace that combines a valgus effect with knee and tibial external rotation during gait in medial osteoarthritis patients. Methods Twenty patients with unilateral symptomatic medial knee osteoarthritis were included and they performed two test sessions of 3D gait analysis with and without the brace at the initial evaluation (W0) and after 5weeks (W5…

musculoskeletal diseasesMalemedicine.medical_specialtyWOMACVisual Analog ScaleOsteoarthritisPhysical medicine and rehabilitationmedicineHumansOrthopedics and Sports MedicineProspective StudiesGaitBracesbiologybusiness.industryEquipment DesignMiddle AgedOsteoarthritis Kneemusculoskeletal systembiology.organism_classificationmedicine.diseaseGaitBraceBiomechanical PhenomenaPreferred walking speedValgusmedicine.anatomical_structurePatient SatisfactionGait analysisFemaleAnklebusinesshuman activitiesLocomotionThe Knee
researchProduct

A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.

2018

Background Displaced transverse patellar fractures require open reduction and internal fixation. State-of-the-art stabilization techniques are tension band wiring (TBW) using Kirschner wires or cannulated screws. These techniques are associated with high rates of secondary fracture displacement, implant migration, implant prominence, wound-healing disturbances, and the need for implant removal. Recently, a locked intraosseous patellar nail prototype was developed. The aim of the present study was to investigate the biomechanical performance of this nail compared with TBW using cannulated screws. Methods Seven paired fresh-frozen human cadaveric knees were stripped of all soft tissues except…

musculoskeletal diseasesMalemedicine.medical_treatmentBone ScrewsKnee InjuriesBone NailsOsteotomy03 medical and health sciencesFracture Fixation InternalFractures Bone0302 clinical medicineCadaverFracture fixationmedicineCadaverInternal fixationHumansOrthopedics and Sports MedicineRange of Motion ArticularOrthodontics030222 orthopedicsbusiness.industryTension band wiring030208 emergency & critical care medicineGeneral MedicinePatellamusculoskeletal systemmedicine.diseaseBiomechanical Phenomenamedicine.anatomical_structureSurgeryFemaleQuadriceps tendonPatella fractureCadaveric spasmbusinessThe Journal of bone and joint surgery. American volume
researchProduct

Effects of muscle activation on shear between human soleus and gastrocnemius muscles

2015

Lateral connections between muscles provide pathways for myofascial force transmission. To elucidate whether these pathways have functional roles in vivo, we examined whether activation could alter the shear between the soleus (SOL) and lateral gastrocnemius (LG) muscles. We hypothesized that selective activation of LG would decrease the stretch-induced shear between LG and SOL. Eleven volunteers underwent a series of knee joint manipulations where plantar flexion force, LG, and SOL muscle fascicle lengths and relative displacement of aponeuroses between the muscles were obtained. Data during a passive full range of motion were recorded, followed by 20° knee extension stretches in both pass…

musculoskeletal diseasesMuscle fascicleAdultKnee Jointtendonmuscle stretchPhysical Therapy Sports Therapy and RehabilitationStimulationKnee Jointshear strain03 medical and health sciencesYoung Adultmuscle contraction0302 clinical medicinemedicineShear stressHumansOrthopedics and Sports MedicineAponeurosisMuscle StrengthRange of Motion Articularmyofascial force transmissionMuscle Skeletalta315activation-dependentChemistry030229 sport sciencesAnatomymusculoskeletal systemHealthy VolunteersTendonBiomechanical Phenomenamedicine.anatomical_structureaponeurosismedicine.symptomRange of motionShear Strength030217 neurology & neurosurgeryMuscle contractionScandinavian Journal of Medicine and Science in Sports
researchProduct

Breaststroke swimmer's knee

1980

The cause of the breaststroke swimmer's knee with medial pain of the knee joint has not been clearly identified. Breaststroke swimmers with knee pain were, therefore, examined arthros copically. None showed any other disorders of their knees than medial synovitis in seven of nine swimmers. Since structural abnormalities could be ruled out, biomechanical analyses utiliz ing cinematographic techniques were used to study patients swimming in a special flume with the speed set at 90% of their best competitive performance. The results indicate that the extension and flexion and also in some cases the hip abduction and adduction movements of the whip kick were performed with high peak angular ve…

musculoskeletal diseasesPainPhysical Therapy Sports Therapy and RehabilitationKnee InjuriesKnee Joint03 medical and health sciences0302 clinical medicineSynovitismedicineHumansOrthopedics and Sports MedicineFemurBreaststrokeTibiaSwimmingOrthodonticsHigh peak030222 orthopedicsbusiness.industryEndoscopy030229 sport sciencesAnatomymusculoskeletal systemmedicine.diseaseBiomechanical PhenomenaKnee painExternal rotationAthletic Injuriesmedicine.symptombusinesshuman activitiesThe American Journal of Sports Medicine
researchProduct

A reanalysis of spinal motion during vibration

1987

Calibrated film of the motion of the lumbar spine during vibration was reanalysed, making use of a number of computer based techniques to improve accuracy and reduce measurement noise. The results demonstrated resonant behaviour at about 4 Hz and indicated that at vibration levels of the order of 1 m/s2 there exists bending of the order of 1° (peak to peak) between adjacent vertebrae in the lumbar spine. The bending is complex and involves phase differences along the spine and possibly a rocking motion of the pelvis.

musculoskeletal diseasesPhysicsAcousticsBiomechanicsPhase (waves)Motion (geometry)Physical Therapy Sports Therapy and RehabilitationHuman Factors and ErgonomicsBody movementBendingAnatomymusculoskeletal systemVibrationNoise (electronics)SpineBiomechanical PhenomenaVibrationHumansRachisErgonomics
researchProduct

Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept

2020

Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsi…

musculoskeletal diseasesSacrumMaterials sciencePercutaneousmedicine.medical_treatmentBone Screws0206 medical engineering02 engineering and technologyOsteotomyPelvisScrew fixationFracture Fixation InternalFractures Bone03 medical and health sciences0302 clinical medicineFragilitymedicineHumansOrthopedics and Sports MedicinePelvis030203 arthritis & rheumatologyOrthodonticsX-Raysequipment and suppliesmusculoskeletal systemSacrum020601 biomedical engineeringBiomechanical PhenomenaOsteotomyRadiographysurgical procedures operativemedicine.anatomical_structureSpinal FracturesStress MechanicalImplantTest protocolJournal of Orthopaedic Research
researchProduct

Enhanced prolylhydroxylase activity in the posterior annulus fibrosus of canine intervertebral discs following long-term running exercise

2010

The effect of long-term excercise on the intervertebral disc collagen concentration (hydroxyproline), collagen-synthesizing enzymes (prolyl-4-hydroxylase, PH, and galactosyl-hydroxylysyl glucosyltransferase, GGT) and hydroxypyridinium crosslinks was studied in ten female beagle dogs. The dogs were run on a treadmill for 1 year starting at the age of 15 weeks. The daily running distance was gradually increased to 40km, which distance the dogs ran for the final 15 weeks. Ten untrained dogs from the same breeding colony served as controls. The nucleus pulposus and anterior and posterior halves of the annulus fibrosus of C2-3, T10-12, L4-5 disc segments were analysed. Crosslinks were measured f…

musculoskeletal diseasesTime FactorsProcollagen-Proline DioxygenaseBeagleThoracic VertebraeHydroxyprolinechemistry.chemical_compoundDogsLumbarStress PhysiologicalPhysical Conditioning AnimalmedicineAnimalsOrthopedics and Sports MedicineTreadmillIntervertebral DiscAnnulus (mycology)Lumbar VertebraePhysical conditioningbusiness.industryIntervertebral discAnatomymusculoskeletal systemBiomechanical PhenomenaHydroxyprolinemedicine.anatomical_structurechemistryGlucosyltransferasesModels AnimalCollagen metabolismCervical VertebraePhysical EnduranceFemaleSurgeryCollagenbusinessEuropean Spine Journal
researchProduct

Kinematics of the ulna during pronation and supination in a cadaver study: implications for elbow arthroplasty

2003

Objective. Aim of this study was to exactly describe and quantify kinematics of the ulna during pro- and supination. Design. Biomechanical study in fresh frozen cadavers. Background. A previous MRI study revealed a varus/valgus motion of the ulna averaging 7.1° during pro-/supination. Axial rotation, however, could not be quantified. Methods. Sixteen arms were examined in a new apparatus that fixed the humerus on a template and allowed forearm rotation. Motion of a Kirschner wire placed in the ulna was recorded in steps of 30° by two perpendicularly arranged charge coupled device cameras during pro- and supination. Results. From supination to pronation the ulna showed a semi-lunar evasive m…

musculoskeletal diseasesanimal structuresElbowBiophysicsUlnaForearmCadaverSupine PositionmedicineHumansPronationOrthopedics and Sports MedicineKirschner wireHumerusArthroplasty Replacementbiologybusiness.industryUlnaAnatomymusculoskeletal systembiology.organism_classificationBiomechanical Phenomenabody regionsValgusmedicine.anatomical_structureCoronal planebusinessBone WiresClinical Biomechanics
researchProduct

Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis

2015

In factures of the distal tibia with simple articular extension, the optimal surgical treatment remains debatable. In clinical practice, minimally invasive plate osteosynthesis and intramedullary nailing are both routinely performed. Comparative biomechanical studies of different types of osteosynthesis of intraarticular distal tibial fractures are missing due to the lack of an established model. The goal of this study was first to establish a biomechanical model and second to investigate, which are the biomechanical advantages of angle-stable plate osteosynthesis and intramedullary nailing of distal intraarticular tibial fractures. Seven 4(th) generation biomechanical composite tibiae feat…

musculoskeletal diseasesmedicine.medical_specialtyIntra-Articular Fracturesmedicine.medical_treatmentBone ScrewsTorsion MechanicalBone Nailsmedicine.disease_causeOsteotomyWeight-bearingBiomechanical Phenomenalaw.inventionWeight-BearingIntramedullary rodFixation (surgical)lawBone platemedicineHumansGeneral Environmental ScienceOrthodonticsOsteosynthesisbusiness.industrymusculoskeletal systemBiomechanical PhenomenaFracture Fixation IntramedullaryOsteotomySurgeryTibial FracturesFeasibility StudiesGeneral Earth and Planetary SciencesImplantbusinessBone PlatesInjury
researchProduct

Two different posterior-stabilized mobile-bearing TKA designs: navigator evaluation of intraoperative kinematic differences

2020

Purpose: The purpose of this study was to compare two types of posterior-stabilized (PS) mobile-bearing (MB) total knee arthroplasties (TKAs). The hypothesis was that no major differences were going to be found among the two TKA designs. Methods: Two cohorts of patients who were divided according to implant design (Cohort A, new design gradually reducing radius PS MB TKA; Cohort B, traditional dual-radius PS MB TKA) were analyzed by means of intraoperative navigation. All operations were guided by a non-image-based navigation system that recorded relative femoral and tibial positions in native and implanted knees during the following kinematic tests: passive range of motion (PROM), varus–va…

musculoskeletal diseasesmedicine.medical_specialtyKinematicsKnee Jointmedicine.medical_treatmentComparisonKinematicsPromProsthesis DesignProsthesis03 medical and health sciences0302 clinical medicinemedicineHumansOrthopedics and Sports MedicinePosterior-stabilized kneeRange of Motion ArticularSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeArthroplasty Replacement KneeOrthodontics030222 orthopedicsKnee laxitybusiness.industryTKAPosterior stabilized030229 sport sciencesKinematicmusculoskeletal systemNavigationBiomechanical PhenomenaSurgeryCohortOrthopedic surgerySurgeryMobile bearingKnee ProsthesisRange of motionbusinessMUSCULOSKELETAL SURGERY
researchProduct