Search results for "Medical device"
showing 7 items of 47 documents
Dataset related to the article "LITHOTRIPSY OF CALCIFIED AORTIC VALVE LEAFLETS BY A NOVEL ULTRASOUND TRANSCATHETER-BASED DEVICE"
2022
This record contains raw data related to the article “LITHOTRIPSY OF CALCIFIED AORTIC VALVE LEAFLETS BY A NOVEL ULTRASOUND TRANSCATHETER-BASED DEVICE” The increasing incidence of calcific aortic valve disease necessitates the elaboration of new strategies to retard the progression of the pathology with an innovative solution. While the increasing diffusion of the transcatheter aortic valve replacements (TAVRs) allows a mini-invasive approach to aortic valve substitution as an alternative to conventional surgical replacement (SAVR) in an always larger patient population, TAVR implantation still has contraindications for young patients. In addition, it is liable to undergo calcification with …
A portable multisensor system to assess cardiorespiratory interactions through photoplethysmography
2022
Nowadays, the ever-growing interest to health and quality of life of individuals and the advancements in electronic devices technology are pushing the development of portable and wearable biomedical devices able to pursue a minimally invasive monitoring of physiological parameters in daily-life conditions. Such devices can now carry out a real-time assessment of the subjects’ overall health status and possibly even detect ongoing diseases. In this context, we have designed and implemented a multisensor portable system able to perform synchronous real-time acquisitions of electrocardiographic (ECG), photoplethysmographic (PPG) and airflow breathing signals. We investigated cardiorespiratory …
Low-invasive multisensor real-time acquisition system for the assessment of cardiorespiratory and skin conductance parameters
2022
In recent years, the attention to the health and comfort of the individual, together with the electronic miniaturization progress, have led to an increased interest in the development of biomedical devices that are able to acquire a multitude of biomedical signals. Such devices should be wearable and comfortable during daily use, to be thus suitable for continuously monitoring psychophysical health states. In this context, we have designed and realized a portable biomedical device capable of real-time acquisition of electrocardiographic (ECG), photoplethysmographic (PPG), breathing and galvanic skin response (GSR) signals, for a noninvasive monitoring of multiple physiological parameters. T…
Lithotripsy of Calcified Aortic Valve Leaflets by a Novel Ultrasound Transcatheter-Based Device
2022
The increasing incidence of calcific aortic valve disease necessitates the elaboration of new strategies to retard the progression of the pathology with an innovative solution. While the increasing diffusion of the transcatheter aortic valve replacements (TAVRs) allows a mini-invasive approach to aortic valve substitution as an alternative to conventional surgical replacement (SAVR) in an always larger patient population, TAVR implantation still has contraindications for young patients. In addition, it is liable to undergo calcification with the consequent necessity of re-intervention with conventional valve surgery or repeated implantation in the so-called TAVR-in-TAVR procedure. Inspired …
Beneficial Effect of Foot Plantar Stimulation in Gait Parameters in Individuals with Parkinson’s Disease
2020
New treatments based on peripheral stimulation of the sensory-motor system have shown to be promising in rehabilitation strategies for patients with neurological disorders, including Parkinson's disease (PD), especially in regards to reducing gait impairment, and hence, the incidence of falls. The aim of this study was to evaluate the change in several gait parameters measured by sensor inertial measurement in PD patients after acute plantar stimulation, under the distal phalanx of the big toe, and underneath the head of the first metatarsal joint of both feet, using a 3D printing insole. In order to assess whether the effects are selective for PD patients, we compared the effect of the tre…
Deposition and characterization of coatings of Hydroxyapatite, Chitosan, and Hydroxyapatite-Chitosan on 316L for biomedical devices
2018
In the last decades, the scientific community has turned on great interest towards the development of increasingly performing biomedical systems. In the orthopedic field, biomedical devices are made up by metallic materials (mainly steel and titanium alloys), which have low/medium resistance to corrosion and a low osteointegration capacity when implanted inside the human body. This can lead to infection or inflammation that can damage the tissues surrounding the implant. The use of biocompatible coatings allows cancelling or mitigating these phenomena. The coating interposing between aggressive environment and biomedical device inhibits corrosion so limiting the metal ions release into the …
Lääkintälaitteiden kyberturvallisuuden standardit ja testaaminen
2017
Tietotekniikkaa sisältävät lääkintälaitteet pitävät meidät hengissä, jos kehomme pettää. Esimerkiksi ostoskeskuksissa olevat älykkäät defibrillaattorit antavat maallikoillekin mahdollisuuden antaa tehokasta ensiapua sydänkohtaukseen. Tietotekniikan käyttäminen lääkintälaitteissa tuo mahdollisuuksien lisäksi uhkia. Tässä tutkielmassa perehdytään siihen, miten standardit ja testaaminen edistävät kyberturvallisuutta, uhkien torjumista. Ensin tehdään katsaus kirjallisuuteen ja standardeihin ja sitten kytketään tieto käytäntöön testaamalla potilasmonitoria kirjallisuuden pohjalta. Tulos oli, että tutkittava potilasmonitori oli hyvin avoin fyysisen käyttöliittymän kautta. Esimerkiksi potilastiedo…