Search results for "Medical physics"
showing 10 items of 579 documents
SU-FF-T-13: Monte Carlo Calculation of the TG-43 Dosimetric Parameters of a New BEBIG Ir-192 HDR Source
2005
Purpose: High dose rate (HDR) brachytherapy is a highly extended practice in clinical brachytherapy today. Quality dose rate distribution datasets of the HDR sources used in a clinical treatment are required. Because of the different source designs, a specific dosimetry dataset is required for each source model. In the recently published BRAPHYQS-ESTRO Report, an overview of available dosimetric data for all HDR Ir-192 sources is given, pointing out the lack of data for one of the sources, the used by the BEBIG MultiSource afterloading system (BEBIG GmbH, Germany). The purpose of this study is to obtain detailed dose rate distributions in liquid water media around this source. Material and …
SU-FF-T-329: Monte Carlo Dosimetric Study of the Flexisource Ir-192 HDR Source
2006
Purpose:Brachytherapy with high dose rate (HDR) sources of 192 Ir is a usual practice in clinical brachytherapy today. The TG43 U1 update report recommends that accurate dose distribution data of the brachytherapysource in use should be obtained experimentally or by Monte Carlo (MC), to be used as input in the HDR Treatment Planning System (TPS). The purpose of this study is to obtain the dose rate distribution in liquid water media for the Flexisource HDR 192 Ir source (Isodose Control GmbH, Germany) using the Monte Carlo method to obtain the TG43 U1 parameters and the 2‐D rectangular dose rate table. Material and methods: The MC code GEANT4 (7.1 version) was used to estimate dose rate in …
Implementation and Validation of an End-to-End Commissioning Process for Model-Based Dose Calculation Algorithms in Brachytherapy
2016
WE-C-141-01: Research and Relevance of Brachytherapy Dose Calculation Advancements
2013
Research and Relevance of Brachytherapy Dose Calculation Advancements Organizer: Mark J. Rivard Moderator: Geoffrey S. Ibbott Speakers: Facundo Ballester, Asa Carlsson Tedgren, Firas Mourtada Brachytherapy dosimetry is undergoing a renaissance with the scrutiny of the AAPM TG‐43 dose calculation formalism and comparisons with alternate approaches such as the Monte Carlo method, the grid‐based Boltzmann solvers, and the collapsed‐cone technique. Treatment planning systems (TPS) using these more advanced, model‐based dose calculation algorithms (MBDCAs) are now available for clinical use. However, their accuracy and the preferred method for their use have not been established. Thus, it is imp…
Eye lens equivalent dose in interventional neuroradiology based on OSL dosimetry
2016
Over the past years there has been an increase in the assessment of eye lens doses in interventional radiology procedures. This is due to the new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) that proposes to reduce equivalent dose limit for the eye lens. The aim of this study is to make estimates of equivalent dose received by eye lens of the medical staff in interventional neuroradiology procedures. Consequently, this study presents an alternative for eye lens dosimetry. For this purpose nanoDot dosimeters based on optically stimulated luminescence (OSL) technology from Landauer Inc. product were used. The measurements obtained for …
Estimation of equivalent dose to the eye lens and hands in wrist surgery using OSL dosimetry
2016
The new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) proposes reducing the limit of equivalent dose to the eye lens. For this reason, it is necessary to make estimates about received equivalent dose to the eye lens of medical staff. This study provides an alternative to dosimetry of the eye lens and hands, using dosimeters nanoDots based on optically stimulated luminescence (OSL) technology in wrist surgery procedure carried out with fluoroscopy.
Diagnosis and Planning in Immediate Loading: Surgical Diagnosis
2019
For several decades, two-dimensional images were the only available for the surgical diagnosis prior to implant placement. The introduction of digital radiology and software applications for three-dimensional imaging has increased the prospects of success in implant diagnosis and surgical placement. The CBCT is definitely more precise and complete than panoramic radiography, but it is not always mandatory for every case. Success for fixed implant-supported rehabilitations, especially in immediate provisionalization techniques, depends on accurate pre-surgical evaluation of the following issues: (1) recognize feasible restoration procedures to rehabilitate patient edentulism; (2) list all th…
Dentomaxillofacial Radiology in 2020—Exciting developments ahead
2019
IC‐P‐050: The European diffusion tensor imaging study in dementia (EDSD): Physical phantom study and multimodal clinical study on the diagnosis of Al…
2012
Machine Perfusions in Liver Transplantation: The Evidence‐Based Position Paper of the Italian Society of Organ and Tissue Transplantation
2020
The use of machine perfusion (MP) in liver transplantation (LT) is spreading worldwide. However, its efficacy has not been demonstrated, and its proper clinical use has far to go to be widely implemented. The Società Italiana Trapianti d’Organo (SITO) promoted the development of an evidence-based position paper. A 3-step approach has been adopted to develop this position paper. First, SITO appointed a chair and a cochair who then assembled a working group with specific experience of MP in LT. The Guideline Development Group framed the clinical questions into a patient, intervention, control, and outcome (PICO) format, extracted and analyzed the available literature, ranked the quality of th…