Search results for "Medical physics"

showing 10 items of 579 documents

SU-FF-T-13: Monte Carlo Calculation of the TG-43 Dosimetric Parameters of a New BEBIG Ir-192 HDR Source

2005

Purpose: High dose rate (HDR) brachytherapy is a highly extended practice in clinical brachytherapy today. Quality dose rate distribution datasets of the HDR sources used in a clinical treatment are required. Because of the different source designs, a specific dosimetry dataset is required for each source model. In the recently published BRAPHYQS-ESTRO Report, an overview of available dosimetric data for all HDR Ir-192 sources is given, pointing out the lack of data for one of the sources, the used by the BEBIG MultiSource afterloading system (BEBIG GmbH, Germany). The purpose of this study is to obtain detailed dose rate distributions in liquid water media around this source. Material and …

medicine.medical_specialtyDose calculationComputer sciencemedicine.medical_treatmentBrachytherapyMonte Carlo methodmedicineDosimetryMedical physicsGeneral MedicineDose rateClinical treatmentAlgorithmMedical Physics
researchProduct

SU-FF-T-329: Monte Carlo Dosimetric Study of the Flexisource Ir-192 HDR Source

2006

Purpose:Brachytherapy with high dose rate (HDR) sources of 192 Ir is a usual practice in clinical brachytherapy today. The TG43 U1 update report recommends that accurate dose distribution data of the brachytherapysource in use should be obtained experimentally or by Monte Carlo (MC), to be used as input in the HDR Treatment Planning System (TPS). The purpose of this study is to obtain the dose rate distribution in liquid water media for the Flexisource HDR 192 Ir source (Isodose Control GmbH, Germany) using the Monte Carlo method to obtain the TG43 U1 parameters and the 2‐D rectangular dose rate table. Material and methods: The MC code GEANT4 (7.1 version) was used to estimate dose rate in …

medicine.medical_specialtyDose calculationComputer sciencemedicine.medical_treatmentMonte Carlo methodBrachytherapymedicineDosimetryMedical physicsGeneral MedicineDose rateRadiation treatment planningAlgorithmMedical Physics
researchProduct

Implementation and Validation of an End-to-End Commissioning Process for Model-Based Dose Calculation Algorithms in Brachytherapy

2016

medicine.medical_specialtyDose calculationProject commissioningbusiness.industrymedicine.medical_treatmentBrachytherapyProcess (computing)Reliability engineeringOncologyEnd-to-end principlemedicineRadiology Nuclear Medicine and imagingMedical physicsbusinessBrachytherapy
researchProduct

WE-C-141-01: Research and Relevance of Brachytherapy Dose Calculation Advancements

2013

Research and Relevance of Brachytherapy Dose Calculation Advancements Organizer: Mark J. Rivard Moderator: Geoffrey S. Ibbott Speakers: Facundo Ballester, Asa Carlsson Tedgren, Firas Mourtada Brachytherapy dosimetry is undergoing a renaissance with the scrutiny of the AAPM TG‐43 dose calculation formalism and comparisons with alternate approaches such as the Monte Carlo method, the grid‐based Boltzmann solvers, and the collapsed‐cone technique. Treatment planning systems (TPS) using these more advanced, model‐based dose calculation algorithms (MBDCAs) are now available for clinical use. However, their accuracy and the preferred method for their use have not been established. Thus, it is imp…

medicine.medical_specialtyDose calculationbusiness.industrymedicine.medical_treatmentBrachytherapyThe RenaissanceGeneral MedicineMedical physicistmedicineBenchmark (computing)DosimetryRelevance (information retrieval)Medical physicsRadiation treatment planningbusinessMedical Physics
researchProduct

Eye lens equivalent dose in interventional neuroradiology based on OSL dosimetry

2016

Over the past years there has been an increase in the assessment of eye lens doses in interventional radiology procedures. This is due to the new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) that proposes to reduce equivalent dose limit for the eye lens. The aim of this study is to make estimates of equivalent dose received by eye lens of the medical staff in interventional neuroradiology procedures. Consequently, this study presents an alternative for eye lens dosimetry. For this purpose nanoDot dosimeters based on optically stimulated luminescence (OSL) technology from Landauer Inc. product were used. The measurements obtained for …

medicine.medical_specialtyDosimetergenetic structuresOptically stimulated luminescencemedicine.diagnostic_testEquivalent dosebusiness.industryInterventional radiologyeye diseases030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisRadiological weaponmedicineDosimetryMedical physicssense organsNuclear medicinebusinessInterventional neuroradiologyNeuroradiology2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE)
researchProduct

Estimation of equivalent dose to the eye lens and hands in wrist surgery using OSL dosimetry

2016

The new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) proposes reducing the limit of equivalent dose to the eye lens. For this reason, it is necessary to make estimates about received equivalent dose to the eye lens of medical staff. This study provides an alternative to dosimetry of the eye lens and hands, using dosimeters nanoDots based on optically stimulated luminescence (OSL) technology in wrist surgery procedure carried out with fluoroscopy.

medicine.medical_specialtyDosimetergenetic structuresOptically stimulated luminescencemedicine.diagnostic_testEquivalent dosebusiness.industryWrist surgeryeye diseases030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisRadiological weaponMedicineDosimetryFluoroscopyMedical physicssense organsEye lensbusinessNuclear medicine2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE)
researchProduct

Diagnosis and Planning in Immediate Loading: Surgical Diagnosis

2019

For several decades, two-dimensional images were the only available for the surgical diagnosis prior to implant placement. The introduction of digital radiology and software applications for three-dimensional imaging has increased the prospects of success in implant diagnosis and surgical placement. The CBCT is definitely more precise and complete than panoramic radiography, but it is not always mandatory for every case. Success for fixed implant-supported rehabilitations, especially in immediate provisionalization techniques, depends on accurate pre-surgical evaluation of the following issues: (1) recognize feasible restoration procedures to rehabilitate patient edentulism; (2) list all th…

medicine.medical_specialtyEdentulismbusiness.industryRadiographymedicine.diseaseSurgical planningOsseointegrationResonance frequency analysisImmediate loadingmedicineMedical physicsImplantSurgical diagnosisbusiness
researchProduct

Dentomaxillofacial Radiology in 2020—Exciting developments ahead

2019

medicine.medical_specialtyEditorialOtorhinolaryngologybusiness.industryMEDLINEmedicineRadiology Nuclear Medicine and imagingMedical physicsGeneral MedicinebusinessGeneral DentistryDentomaxillofacial Radiology
researchProduct

IC‐P‐050: The European diffusion tensor imaging study in dementia (EDSD): Physical phantom study and multimodal clinical study on the diagnosis of Al…

2012

medicine.medical_specialtyEpidemiologybusiness.industryHealth PolicyDiseasemedicine.diseaseImaging phantomClinical studyPsychiatry and Mental healthCellular and Molecular NeuroscienceDevelopmental NeurosciencemedicineDementiaMedical physicsNeurology (clinical)Geriatrics and GerontologybusinessNeuroscienceDiffusion MRIAlzheimer's & Dementia
researchProduct

Machine Perfusions in Liver Transplantation: The Evidence‐Based Position Paper of the Italian Society of Organ and Tissue Transplantation

2020

The use of machine perfusion (MP) in liver transplantation (LT) is spreading worldwide. However, its efficacy has not been demonstrated, and its proper clinical use has far to go to be widely implemented. The Società Italiana Trapianti d’Organo (SITO) promoted the development of an evidence-based position paper. A 3-step approach has been adopted to develop this position paper. First, SITO appointed a chair and a cochair who then assembled a working group with specific experience of MP in LT. The Guideline Development Group framed the clinical questions into a patient, intervention, control, and outcome (PICO) format, extracted and analyzed the available literature, ranked the quality of th…

medicine.medical_specialtyEvidence-based practice2747 TransplantationGRADE; donor after circulatory death; donor brain death; hypothermic machine; liver transplant; machine perfusion; normothermic machine; normothermic regional perfusion; position papermedicine.medical_treatmentDelphi methodMEDLINEhypothermic machine610 Medicine & healthdonor after circulatory deathliver perfusion machine030230 surgeryLiver transplantationnormothermic regional perfusionliver03 medical and health sciences0302 clinical medicinenormothermic machineHumansMedicineMedical physics10217 Clinic for Visceral and Transplantation SurgeryHumansItalyTransplantationMachine perfusionHepatologybusiness.industrymachine perfusionOrgan Preservationdonor brain deathperfusion machineInstitutional review boardLiver Transplantation2746 SurgeryPerfusionTransplantationliver transplantGRADEItalyPosition paper2721 Hepatology030211 gastroenterology & hepatologySurgerybusinessposition paperHumanLiver Transplantation
researchProduct