Search results for "Medical procedure"

showing 10 items of 102 documents

Primary Cytomegalovirus Infection in Seronegative Kidney Transplant Patients Is Associated with Protracted Cold Ischemic Time of Seropositive Donor O…

2017

Human Cytomegalovirus (CMV) can lead to primary infection or reactivation in CMV-seronegative or -seropositive kidney transplant recipients, respectively. Complications comprise severe end-organ diseases and acute or chronic transplant rejection. Risk for CMV manifestation is stratified according to the CMV-IgG-serostatus, with donor+/recipient- (D+/R-) patients carrying the highest risk for CMV-replication. However, risk factors predisposing for primary infection in CMV-seronegative recipients are still not fully elucidated. Therefore, we monitored D+/R- high-risk patients undergoing kidney transplantation in combination with antiviral prophylaxis for the incidence of CMV-viremia for a med…

Cytomegalovirus InfectionMaleViral DiseasesT-Lymphocyteslcsh:MedicineCytomegalovirusPathology and Laboratory MedicineCell-Mediated ImmunityWhite Blood CellsAnimal CellsMedicine and Health SciencesRenal TransplantationPublic and Occupational Healthlcsh:ScienceImmunity CellularT CellsCold Ischemiavirus diseasesVaccination and ImmunizationTissue DonorsInfectious DiseasesMedical MicrobiologyViral PathogensVirusesCytomegalovirus InfectionsHuman CytomegalovirusFemaleCellular TypesPathogensResearch ArticleHerpesvirusesImmune CellsImmunologySurgical and Invasive Medical ProceduresCytotoxic T cellsSerogroupMicrobiologyUrinary System ProceduresHumansViremiaMicrobial PathogensTransplantationBlood CellsProphylaxislcsh:ROrganismsImmunityBiology and Life SciencesCell BiologyOrgan TransplantationKidney Transplantationlcsh:QPreventive MedicineDNA virusesPLoS ONE
researchProduct

The short-term efficacy and safety of artificial total disc replacement for selected patients with lumbar degenerative disc disease compared with ant…

2018

PurposeTo systematically compare the efficacy and safety of lumbar total disc replacement (TDR) with the efficacy and safety of anterior lumbar interbody fusion (ALIF) for the treatment of lumbar degenerative disc disease (LDDD).MethodsThe electronic databases PubMed, Web of Science and the Cochrane Library were searched for the period from the establishment of the databases to March 2018. The peer-reviewed articles that investigate the safety and efficacy of TDR and ALIF were retrieved under the given search terms. Quality assessment must be done independently by two authors according to each item of criterion. The statistical analyses were performed using RevMan (version 5.3) and Stata (v…

Databases FactualIntervertebral Disc DegenerationCochrane Librarylaw.inventionDatabase and Informatics MethodsMathematical and Statistical Techniques0302 clinical medicineRandomized controlled triallawMedicine and Health SciencesRange of Motion ArticularDatabase Searching030222 orthopedicsMultidisciplinaryQStatisticsRMetaanalysisResearch AssessmentHospitalsTreatment OutcomeResearch DesignMeta-analysisPhysical SciencesObservational StudiesMedicineRange of motionResearch ArticleTotal Disc Replacementmedicine.medical_specialtySystematic ReviewsClinical Research DesignScienceSurgical and Invasive Medical ProceduresResearch and Analysis MethodsDegenerative disc disease03 medical and health sciencesLumbarmedicineHumansStatistical Methodsbusiness.industryEvidence-based medicinemedicine.diseaseSurgeryHealth CareSpinal FusionHealth Care FacilitiesObservational studyAdverse EventsbusinessPublication BiasMathematics030217 neurology & neurosurgeryPLOS ONE
researchProduct

Computer-assisted clinical diagnosis in the official European union languages

2016

eHealth services integrate Web Information Retrieval and Intelligent Medical Decision Support for health care professionals based on the range of possible symptoms which a patient reports. However, many symptoms like high temperature, fever, or headache, are ambiguous in terms of suggesting wide variety of possible patient's conditions to the GP, while other symptoms are mutually dependant, which again can be misleading to make an accurate diagnosis. On the other hand, doctor's up-to-date knowledge on the medicaments, drugs, active medical substances included, anticipated range of diseases relating to the symptoms reported, and the most reliable pharmaceutical manufacturers, are of the grea…

Decision support systemehealthMedical procedure0102 computer and information sciences01 natural sciencesHealth informatics030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineNursingHealth careeHealthmedicinemedical informaticsmedia_common.cataloged_instanceMedical historyinformation retrievalEuropean unionmedia_commonbusiness.industrypattern recognitionmedicine.disease010201 computation theory & mathematicsMedical emergencyDependantbusinessdecision support systems2016 IEEE 18th International Conference on e-Health Networking, Applications and Services (Healthcom)
researchProduct

Fractal-structured multifocal intraocular lens

2017

[EN] In this work, we present a new concept of IOL design inspired by the demonstrated properties of reduced chromatic aberration and extended depth of focus of Fractal zone plates. A detailed description of a proof of concept IOL is provided. The result was numerically characterized, and fabricated by lathe turning. The prototype was tested in vitro using dedicated optical system and software. The theoretical Point Spread Function along the optical axis, computed for several wavelengths, showed that for each wavelength, the IOL produces two main foci surrounded by numerous secondary foci that partially overlap each other for different wavelengths. The result is that both, the near focus an…

DiffractionOptical PhenomenaFocus (geometry)VisionSocial Scienceslcsh:MedicinePhysics::Optics01 natural sciences0302 clinical medicineMedicine and Health SciencesPsychologylcsh:ScienceLens (Anatomy)PhysicsMultidisciplinaryPhysicsOphthalmic ProceduresCataract SurgeryOptical LensesWavelengthFractalsOptical EquipmentPhysical SciencesEngineering and TechnologySensory PerceptionAnatomyDiffractionResearch ArticlePoint spread functionOcular AnatomyGeometryEquipmentSurgical and Invasive Medical ProceduresIn Vitro TechniquesProsthesis DesignProof of Concept Study010309 optics03 medical and health sciencesFractalOpticsOcular SystemOptical transfer function0103 physical sciencesChromatic aberrationPrototypesComputer Simulationbusiness.industrylcsh:RBiology and Life SciencesModels TheoreticalMultifocal Intraocular LensesOptical axisTechnology DevelopmentFISICA APLICADAWaves030221 ophthalmology & optometryEyeslcsh:QbusinessHeadMathematicsNeuroscience
researchProduct

Internal limiting membrane peeling versus no peeling during primary vitrectomy for rhegmatogenous retinal detachment: A systematic review and meta-an…

2018

Background Internal limiting membrane (ILM) peeling during primary vitrectomy for rhegmatogenous retinal detachment (RRD) prevents the formation of postoperative macular epiretinal membrane (ERM). However, studies that compared vitrectomy with and without ILM peeling for RRD, have reported controversial outcomes. Objective To assess the efficacy of ILM peeling versus non-ILM peeling during vitrectomy for RRD by a systematic review and meta-analysis of published studies. Methods PubMed, Medline, Web of Science, Embase databases, and the Cochrane Library were searched up to April 2018 to identify studies that compared primary vitrectomy with and without ILM peeling for RRD with at least six m…

Genetics and Molecular Biology (all)Visual acuitygenetic structuresVisionmedicine.medical_treatmentVisual Acuitylcsh:MedicineSocial SciencesVitrectomyBiochemistrylaw.inventionDatabase and Informatics Methods0302 clinical medicineMathematical and Statistical TechniquesPostoperative ComplicationsRandomized controlled trialBiochemistry Genetics and Molecular Biology (all); Agricultural and Biological Sciences (all)lawVitrectomyMedicine and Health SciencesPsychology030212 general & internal medicineDatabase Searchinglcsh:ScienceMultidisciplinaryOphthalmic ProceduresRetinal detachmentEpiretinal MembraneResearch AssessmentMeta-analysisPhysical SciencesRetinal DisordersSensory PerceptionEpiretinal membranemedicine.symptomAnatomyStatistics (Mathematics)HumanResearch Articlemedicine.medical_specialtySystematic ReviewsSurgical and Invasive Medical ProceduresResearch and Analysis Methods03 medical and health sciencesOcular SystemOphthalmologymedicineHumansStatistical MethodsBiochemistry Genetics and Molecular Biology (all)Primary vitrectomybusiness.industryInternal limiting membranelcsh:RRetinal DetachmentBiochemistry; Genetics and Molecular Biology (all); Agricultural and Biological Sciences (all)Biology and Life Sciencesmedicine.diseaseeye diseasesbody regionsOphthalmologyAgricultural and Biological Sciences (all)030221 ophthalmology & optometryEyeslcsh:QPostoperative Complicationsense organsbusinessHeadMathematicsMeta-AnalysisNeuroscience
researchProduct

Endovascular stentectomy using the snare over stent-retriever (SOS) technique: An experimental feasibility study

2017

PLoS one 12(5), e0178197 (2017). doi:10.1371/journal.pone.0178197

GlycerolSwinePhysiologylcsh:Medicine030218 nuclear medicine & medical imaging0302 clinical medicinePig ModelsBlood FlowMedicine and Health SciencesMedicinelcsh:ScienceData flow modelClinical scenarioMammalsMultidisciplinaryExperimental DesignEndovascular ProceduresVasospasmAnimal ModelsProsthesis FailureBody FluidsPhysical sciencesChemistryBloodExperimental Organism SystemsResearch DesignVertebratesFemaleStentsRadiologyAnatomyResearch ArticleBiotechnologymedicine.medical_specialtyCathetersSurgical and Invasive Medical ProceduresMonomers (Chemistry)Research and Analysis Methods03 medical and health sciencesAnimal modelText miningIn vivoBlood vessel prosthesisAnimalsHumansPolymer chemistryStent retrieverbusiness.industrylcsh:ROrganismsBiology and Life Sciencesmedicine.diseaseBlood Vessel ProsthesisDisease Models AnimalStent ImplantationAmniotesFeasibility StudiesMedical Devices and Equipmentlcsh:Qbusiness030217 neurology & neurosurgeryPLOS ONE
researchProduct

Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry.

2016

AIMS The tonographic effect is a phenomenon of intraocular pressure (IOP) reduction following repeated tonometry. This study examines whether the tonographic effect occurs following IOP measurement performed with Ocular Response Analyzer (ORA). METHODS Both eyes of 31 glaucoma patients and 35 healthy controls underwent nine IOP-measurements performed with GAT and ORA. The number of GAT and ORA measurements performed on each eye differed depending on the randomly allocated investigation scheme. Central corneal thickness (CCT), anterior chamber volume (ACV) and anterior chamber depth (ACD) were assessed with Pentacam before and after the repeated GAT/ORA measurements. RESULTS There was no sta…

Intraocular pressuregenetic structuresEye DiseasesPhysiologyGlaucomalcsh:MedicineWalkingGoldmann applanation tonometryCornea0302 clinical medicineMedicine and Health SciencesMedicineBiomechanicslcsh:ScienceMultidisciplinaryOphthalmic ProceduresDrugsMiddle AgedFemaleAnatomyResearch ArticleAdultmedicine.medical_specialtyOcular AnatomySurgical and Invasive Medical ProceduresCorneal hysteresis03 medical and health sciencesTonometry OcularOcular SystemOphthalmologyHumansPain ManagementIn patientIntraocular PressureAgedAnestheticsPharmacologybusiness.industryBiological Locomotionlcsh:RBiology and Life SciencesGlaucomamedicine.diseaseeye diseasesOphthalmologyCase-Control Studies030221 ophthalmology & optometryEyeslcsh:Qsense organsbusinessHead030217 neurology & neurosurgeryPloS one
researchProduct

Extracellular Matrix Molecular Remodeling in Human Liver Fibrosis Evolution

2016

Chronic liver damage leads to pathological accumulation of ECM proteins (liver fibrosis). Comprehensive characterization of the human ECM molecular composition is essential for gaining insights into the mechanisms of liver disease. To date, studies of ECM remodeling in human liver diseases have been hampered by the unavailability of purified ECM. Here, we developed a decellularization method to purify ECM scaffolds from human liver tissues. Histological and electron microscopy analyses demonstrated that the ECM scaffolds, devoid of plasma and cellular components, preserved the three-dimensional ECM structure and zonal distribution of ECM components. This method has been then applied on 57 l…

Liver Cirrhosis0301 basic medicineProteomicsPathologyProteomeBiopsylcsh:MedicineHepacivirusMatrix (biology)ProteomicsBiochemistryExtracellular matrixMiceLiver disease0302 clinical medicineFibrosisSettore BIO/13 - Biologia ApplicataMedicine and Health Scienceslcsh:Scienceliver fibrosisExtracellular Matrix ProteinsMultidisciplinaryDecellularizationAnimals; Extracellular Matrix; Hepacivirus; Humans; Liver; Liver Cirrhosis; Mice; Proteome; Proteomics; Tissue Scaffolds; Disease ProgressionTissue ScaffoldsChemistryLiver DiseasesLiver030220 oncology & carcinogenesisProteomeDisease ProgressionCellular Structures and OrganellesAnatomyliver fibrosis; extracellular matrix; proteomicsResearch Articlemedicine.medical_specialtyHistologySettore BIO/06extracellular matrixSurgical and Invasive Medical ProceduresGastroenterology and HepatologyScaffold03 medical and health sciencesmedicineAnimalsHumansHuman liverlcsh:RBiology and Life SciencesProteinsCell Biologymedicine.diseaseFibrosisLiver Fibrosi030104 developmental biologyLiver Fibrosis; Scaffold; Proteomicslcsh:QCollagensDevelopmental Biology
researchProduct

Serological Tests Do Not Predict Residual Fibrosis in Hepatitis C Cirrhotics with a Sustained Virological Response to Interferon

2016

BACKGROUND AND AIM: Liver biopsy (LB) has lost popularity to stage liver fibrosis in the era of highly effective anti-hepatitis C virus (HCV) therapy, yet diagnosis of persistent cirrhosis may have important implications following HCV eradication. As performance of serological non-invasive tests (NITs) to predict residual fibrosis in non-viremic HCV patients is unknown, we investigated accuracy of NITs to predict residual fibrosis in cirrhotics after a sustained virological response (SVR) to interferon (IFN). METHODS: Thirty-eight patients with a pre-treatment histological diagnosis of cirrhosis and a 48–104 months post-SVR LB were tested with APRI, CDS, FIB-4, FibroQ, Forns Score, GUCI Ind…

Liver CirrhosisMalePathologyCirrhosisBiopsylcsh:MedicineHepacivirusPathology and Laboratory MedicineGastroenterology0302 clinical medicineEsophageal varicesFibrosisOutcome Assessment Health CareMedicine and Health Scienceslcsh:ScienceSerodiagnosisMultidisciplinarymedicine.diagnostic_testLiver DiseasesHepatitis CMiddle AgedHepatitis C3. Good healthSerologyCirrhosisLiver030220 oncology & carcinogenesisLiver biopsyHepatocellular carcinomaHost-Pathogen InteractionsLiver FibrosisElasticity Imaging Techniques030211 gastroenterology & hepatologyFemaleAnatomyResearch Articlemedicine.medical_specialtyHistologySurgical and Invasive Medical ProceduresGastroenterology and HepatologyAntiviral Agents03 medical and health sciencesDiagnostic MedicineInternal medicineBiopsymedicineHumansSerologic TestsAspartate AminotransferasesAgedbusiness.industryPlatelet Countlcsh:RBiology and Life Sciencesmedicine.diseaseFibrosisROC Curvelcsh:QInterferonsTransient elastographybusinessBiomarkersDevelopmental BiologyPLoS ONE
researchProduct

Comparison of two techniques (in vivo and ex-vivo) for evaluating the elastic properties of the ascending aorta: Prospective cohort study.

2021

Introduction Aneurysms of the ascending aorta (AA) correspond to a dilatation of the ascending aorta that progressively evolves over several years. The main complication of aneurysms of the ascending aorta is type A aortic dissection, which is associated with very high rates of morbidity and mortality. Prophylactic ascending aorta replacement guidelines are currently based on maximal AA diameter. However, this criterion is imperfect. Stretching tests on the aorta carried out ex-vivo make it possible to determine the elastic properties of healthy and aneurysmal aortic fragments (tension test, resistance before rupture). For several years now, cardiac magnetic resonance imaging (MRI) has pro…

Magnetic Resonance SpectroscopyVascular MedicineDiagnostic RadiologyStiffnessBreath HoldingAortic aneurysmMedicine and Health SciencesBiomechanicsProspective StudiesPulse wave velocityAortaAortic dissectionMultidisciplinarymedicine.diagnostic_testCardiac cycleRadiology and ImagingQRArteriesMagnetic Resonance ImagingAortic AneurysmBiomechanical PhenomenaDescending aortaPhysical Sciencescardiovascular systemMedicineAnatomyAneurysmsMaterials scienceImaging TechniquesScienceMaterials ScienceMaterial PropertiesMagnetic Resonance Imaging CineSurgical and Invasive Medical ProceduresPulse Wave AnalysisResearch and Analysis MethodsDiagnostic MedicineCardiac magnetic resonance imagingRegistered Report Protocolmedicine.arteryAscending aortamedicineMechanical PropertiesHumansVascular DiseasesAortabusiness.industryBiology and Life Sciencesmedicine.diseaseElasticityCardiovascular AnatomyBlood VesselsNuclear medicinebusinessPLoS ONE
researchProduct