Search results for "Microscope"
showing 10 items of 1412 documents
Modified Graphene Sheet Stacks for Hydrogen Binding
2017
Results are partially obtained using infrastructure of Lithuanian Energy Institute with support of COST Action MP1103 “Nanostructured materials for solid-state hydrogen storage”. Latvian National Research program IMIS2 is greatly acknowledged for financial support
Surface Morphology of Single and Multi-Layer Silicon Nitride Dielectric Nano-Coatings on Silicon Dioxide and Polycrystalline Silicon
2019
Silicon nitride (Si3N4) in a form of single and multi-layer nanofilms is proposed to be used as a dielectric layer in nanocapacitors for operation in harsh environmental conditions. Characterization of surface morphology, roughness and chemical bonds of the Si3N4 coatings has an important role in production process as the surface morphology affects the contact surface with other components of the produced device. Si3N4 was synthesized by using low pressure chemical vapour deposition method and depositing single and multi-layer (3 – 5 layers) nanofilms on SiO2 and polycrystalline silicon (PolySi). The total thickness of the synthesized nanofilms was 20 – 60 nm. Surface morphology was investi…
Application of Tuning Fork Sensors for In-situ Studies of Dynamic Force Interactions Inside Scanning and Transmission Electron Microscopes
2012
Mechanical properties of nanoscale contacts have been probed in-situ by specially developed force sensor based on a quartz tuning fork resonator (TF). Additional control is provided by observation of process in scanning electron microscope (SEM) and transmission electron microscope (TEM). A piezoelectric manipulator allows precise positioning of atomic force microscope (AFM) probe in contact with another electrode and recording of the TF oscillation amplitude and phase while simultaneously visualizing the contact area in electron microscope. Electrostatic control of interaction between the electrodes is demonstrated during observation of the experiment in SEM. In the TEM system the TF senso…
A Novel Fast Volumetric Light Sheet Microscopy
2016
Fast noninvasive three-dimensional (3D) imaging is crucial for the quantitative understanding of highly dynamic biological processes. Over the last decades, several fluorescence microscopy techniques have been developed in order to provide a faster and deeper imaging of thick biological samples [1]. Within this framework, Light Sheet Fluorescence Microscopy (LSFM) has emerged as a powerful imaging tool for 3D imaging of thick samples ranging from single cells to entire animals [2,3].However, to obtain a 3D reconstruction either sample or microscope parts usually need to be moved limiting the acquisition speed and inducing possible interferences in volume recording. To solve this problem, he…
Microneedling dilates the follicular infundibulum and increases transfollicular absorption of liposomal sepia melanin
2015
Gabriel Serrano,1 Patricia Almudéver,2 Juan M Serrano,3 Julio Cortijo,2 Carmen Faus,1 Magda Reyes,1 Inmaculada Expósito,3 Ana Torrens,3 Fernando Millán1 1Clínica Dermatológica Serrano, 2Department of Pharmacology, University of Valencia, 3Research and Development Department, Sesderma Laboratories, Valencia, Spain Abstract: Encapsulation of chemicals in liposomes and microneedling are currently used techniques to enhance the penetration of several substances through skin and hair. In this study, we apply a liposomal melanin–fluorescein compound to an ex vivo model of human skin, using a new electrical microneedling device (Nano…
When the Grafting of Double Decker Phthalocyanines on Si(100)-2 × 1 Partly Affects the Molecular Electronic Structure
2016
International audience; A combined X-ray photoelectron spectroscopy (XPS), scanning tunneling microscopy (STM), and density functional theory (DFT) study has been performed to characterize the adsorbate interaction of lutetium biphthalocyanine (LuPc2) molecules on the Si(100)-2 × 1 surface. Large molecule–substrate adsorption energies are computed and are found to compete with the molecule–molecule interactions of the double decker molecules. A particularly good matching between STM images and computed ones confirms the deformation of the molecule upon the absorption process. The comparison between DFT calculations and XP spectra reveals that the electronic distribution in the two plateaus …
E. Leitz palielināmais stikls uz statīva
2020
Raksts par palielināmajiem stikliem, mikroskopiem un optisko instrumentu ražošanas uzņēmumu "Ernst Leitz Wetzlar", kura ražotais vienkāršais sadalīšanas mikroskops nr. 46 atrodas Latvijas Universitātes Muzeja Botānikas un mikoloģijas kolekciju krājumā.
2019
Ultrasmall polyaminocarboxylate-coated gold nanoparticles (NPs), Au@DTDTPA and Au@TADOTAGA, that have been recently developed exhibit a promising potential for image-guided radiotherapy. In order to render the radiosensitizing effect of these gold nanoparticles even more efficient, the study of their localization in cells is required to better understand the relation between the radiosensitizing properties of the agents and their localization in cells and in tumors. To achieve this goal, post-functionalization of Au@DTDTPA nanoparticles by near-infrared (NIF) organic dyes (aminated derivative of cyanine 5, Cy5-NH2) was performed. The immobilization of organic Cy5-NH2 dyes onto the gold nano…
Alginate encapsulation improves viability and integrity of cryopreserved pancreatic islets and multicellular spheroids: combined fluorescence, scanni…
2007
Extended abstract of a paper presented at MC 2007, 33rd DGE Conference in Saarbrücken, Germany, September 2 – September 7, 2007
Effects of ultrasonically activated irrigants with or without surfactant on smear layer removal after post space preparation
2012
The aim of this study was to compare the effects of different NaOCl and EDTA formulations with/without ultrasonic use on smear layer removal and root canal surface characteristics after post space preparation. Study design: After post space preparations, forty-six teeth were subjected to different post space irrigation regimes; G1, 17% EDTA; G2, 17% EDTA+Ultrasonic activation; G3, EDTA-T; G4, EDTA-T+Ultrasonic activation; G5, NaOCl; G6, NaOCl+Ultrasonic activation. Specimens were examined under scanning electron microscope and scored for debris and smear layer removal and dentinal tubule opening and statistically analyzed with Kruskal Wallis and Dunn's test. Significance value was set at p<…