Search results for "Microscopist"

showing 2 items of 2 documents

Two simple criteria to estimate an objective's performance when imaging in non design tissue clearing solutions

2019

Tissue clearing techniques are undergoing a renaissance motivated by the need to image fluorescent neurons, and other cells, deep in the sample without physical sectioning. Optical transparency is achieved by equilibrating tissues with high refractive index (RI) solutions. When the microscope objective is not perfectly matched to the RI of the cleared sample, aberrations are introduced. We present two simple-to-calculate numerical criteria predicting: (i) the degradation in image quality (brightness and resolution) from optimal conditions of any clearing solution/objective combination; (ii) which objective, among several available, achieves the highest resolution in a given medium. We deriv…

0301 basic medicineBrightnessMicroscopeDeconvolution; Fluorescence; Microscopy; Neuron; Serial optical sectioning; Spherical aberration; Tissue clearingComputer scienceImage qualitySample (material)DeconvolutionFluorescencelaw.invention03 medical and health sciences0302 clinical medicineSimple (abstract algebra)lawSerial optical sectioningMicroscopyFluorescence microscopeMicroscopistSpherical aberrationColoring AgentsSettore MAT/07 - Fisica MatematicaNeuronsMicroscopyTissue clearingGeneral NeuroscienceMicroscopy Tissue clearing Fluorescence Neuron Spherical aberration Serial optical sectioning DeconvolutionNeuronFluorescenceRefractometrySpherical aberration030104 developmental biologyMicroscopy FluorescenceDeconvolutionAlgorithm030217 neurology & neurosurgeryTissue clearing
researchProduct

Toward fast malaria detection by secondary speckle sensing microscopy

2012

Diagnosis of malaria must be rapid, accurate, simple to use, portable and low cost, as suggested by the World Health Organization (WHO). Despite recent efforts, the gold standard remains the light microscopy of a stained blood film. This method can detect low parasitemia and identify different species of Plasmodium. However, it is time consuming, it requires well trained microscopist and good instrumentation to minimize misinterpretation, thus the costs are considerable. Moreover, the equipment cannot be easily transported and installed. In this paper we propose a new technique named "secondary speckle sensing microscopy" ((SM)-M-3) based upon extraction of correlation based statistics of s…

Microscopeocis:(170.4580) Optical diagnostics for medicineocis:(170.0180) MicroscopyBiologylaw.inventionSpeckle patternOpticslawocis:(120.6160) Speckle interferometryMicroscopyComputer visionMicroscopistInstrumentation (computer programming)ocis:(170.6480) Spectroscopy specklebusiness.industryGold standard (test)Atomic and Molecular Physics and OpticsCell StudiesDiagnosis of malariaocis:(170.1470) Blood or tissue constituent monitoringocis:(170.1530) Cell analysisSpeckle imagingArtificial intelligenceocis:(170.3880) Medical and biological imagingbusinessBiotechnologyBiomedical Optics Express
researchProduct