Search results for "Microscopy"

showing 10 items of 3390 documents

In Vivo Molecular Imaging of Somatostatin Receptors in Pancreatic Islet Cells and Neuroendocrine Tumors by Miniaturized Confocal Laser-Scanning Fluor…

2010

The aim of the study was to evaluate real time in vivo molecular imaging of somatostatin receptors (sstrs) using a handheld miniaturized confocal laser scan microscope (CLM) in conjunction with fluorescein-labeled octreotate (OcF) in healthy mice and murine models of neuroendocrine tumors. For CLM a small rigid probe (diameter 7 mm) with an integrated single line laser (488 nm) was used (optical slice thickness 7 μm; lateral resolution 0.7 μm). OcF was synthesized via Fmoc solid-phase peptide synthesis and purified by HPLC showing high-affinity binding to the sstr2 (IC50 6.2 nmol). For in vitro evaluation, rat and human pancreatic cancer cells were used and characterized with respect to its…

medicine.medical_specialtyPathologyConfocalEndocrinology Diabetes and MetabolismClinical BiochemistryMice NudeNeuroendocrine tumorsOctreotideBinding CompetitiveBiochemistryIslets of LangerhansMiceEndocrinologyIn vivoInternal medicinePancreatic cancerCell Line TumormedicineSomatostatin receptor 2AnimalsHumansReceptors SomatostatingeographyMice Inbred BALB Cgeography.geographical_feature_categoryMicroscopy ConfocalMiniaturizationChemistrySomatostatin receptorReverse Transcriptase Polymerase Chain ReactionGene Expression ProfilingBiochemistry (medical)Reproducibility of Resultsmedicine.diseaseIsletFluoresceinsImmunohistochemistryMolecular ImagingNeuroendocrine TumorsEndocrinologyEx vivoThe Journal of Clinical Endocrinology & Metabolism
researchProduct

Confocal Laser Endomicroscopy: Technical Advances and Clinical Applications

2010

Since its introduction in 2004, confocal laser endomicroscopy (CLE) has emerged as a valuable tool for gastrointestinal endoscopic imaging. Endomicroscopy enables the endoscopist to obtain real time in vivo histology during ongoing endoscopy thereby creating “optical biopsies.” To date, numerous studies have shown potential applications of endomicroscopy in the clinical setting, including in vivo diagnosis of esophageal squamous cell carcinoma, Barrett’s esophagus, celiac disease, and colonic polyps. Moreover, recent data suggest the potential application of endomicroscopy in the field of molecular imaging. Additionally, in recent months new applications and developments in the field of con…

medicine.medical_specialtyPathologyGastrointestinal DiseasesEndoscopy GastrointestinalFood and drug administrationEndoscopic imagingConfocal imagingPredictive Value of TestsmedicineEndomicroscopyHumansConfocal laser endomicroscopyMicroscopy ConfocalMucous MembraneHepatologymedicine.diagnostic_testbusiness.industryGastroenterologyEquipment DesignWide fieldMolecular ImagingEndoscopyEndoscopes GastrointestinalGastrointestinal TractRadiologyMolecular imagingbusinessGastroenterology
researchProduct

WITHDRAWN: Defining In Vivo Mucosal Inflammatory Activity Using Laser Scanning Confocal Endomicroscopy in Human Ulcerative Colitis

2008

This article has been withdrawn consistent with Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). The Publisher apologizes for any inconvenience this may cause.

medicine.medical_specialtyPathologyHepatologyLaser scanningbusiness.industryConfocalGastroenterologymedicine.diseaseGastroenterologyUlcerative colitisIn vivoInternal medicineEndomicroscopyMedicinebusinessGastroenterology
researchProduct

Automatic scanning of large tissue areas in neurosurgery using optical coherence tomography

2012

Background With its high spatial and temporal resolution, optical coherence tomography (OCT) is an ideal modality for intra-operative imaging. One possible application is to detect tumour invaded tissue in neurosurgery, e.g. during complete resection of glioblastoma. Ideally, the whole resection cavity is scanned. However, OCT is limited to a small field of view (FOV) and scanning perpendicular to the tissue surface. Methods We present a new method to use OCT for scanning of the resection cavity during neurosurgical resection of brain tumours. The main challenges are creating a map of the cavity, scanning perpendicular to the surface and merging the three-dimensional (3D) data for intra-ope…

medicine.medical_specialtyPathologyMicroscopemedicine.diagnostic_testComputer scienceBiophysicsmedicine.diseaseComplete resectionComputer Science Applicationslaw.inventionTumour tissueOptical coherence tomographylawTemporal resolutionMicroscopymedicineSurgeryNeurosurgeryBiomedical engineeringGlioblastomaThe International Journal of Medical Robotics and Computer Assisted Surgery
researchProduct

Molecular imaging of gastroenteropancreatic neuroendocrine tumors.

2010

Somatostatin-receptor scintigraphy has become an obligatory molecular imaging method in the management of patients with neuroendocrine tumors when metastatic disease is suspected. Using positron emission tomography and new somatostatin analogues, sensitivity of somatostatin receptor imaging has further increased. With a combination of morphologic imaging methods, such as hybrid imaging by PET/CT, this method represents the method of choice in many centers and efforts are under way to translate somatostatin receptor imaging onto a cellular level by endoscopic confocal microscopy. Other clinically relevant functional pathways in neuroendocrine tumors that are accessible by PET imaging are glu…

medicine.medical_specialtyPathologyNeuroendocrine tumorsScintigraphylaw.inventionConfocal microscopylawmedicineHumansReceptors SomatostatinGastrointestinal NeoplasmsMicroscopy Confocalmedicine.diagnostic_testbusiness.industrySomatostatin receptorGastroenterologyPet imagingmedicine.diseaseCarcinoma NeuroendocrineMolecular ImagingPancreatic NeoplasmsNeuroendocrine TumorsSomatostatinPositron emission tomographyPositron-Emission TomographyRadiologyMolecular imagingRadiopharmaceuticalsbusinessGastroenterology clinics of North America
researchProduct

Establishment and Characterization of a Continuous Human Chondrosarcoma Cell Line, ch-2879: Comparative Histologic and Genetic Studies with Its Tumor…

2003

Chondrosarcomas are malignant cartilage-forming tumors that represent the second most common malignant solid tumor of bone. These biologically poorly understood neoplasms vary considerably in clinical presentation and biologic behavior. Chemotherapy and radiation therapy are generally ineffective. Here we describe the establishment and characterization of a new human chondrosarcoma cell line named ch-2879, and we compare the cell line with its tumor of origin. The cell line was established from a recurrent grade 3 chondrosarcoma of the chest wall and characterized by growth kinetics and morphologic studies. Immunocytochemistry and RT-PCR were performed to examine the expression of cartilage…

medicine.medical_specialtyPathologyPopulationCell Culture TechniquesChondrosarcomaBone NeoplasmsChromosomal translocationVimentinPathology and Forensic MedicineCyclin D1Tumor Cells CulturedmedicineHumanseducationMolecular BiologyMetaphaseChromosome Aberrationseducation.field_of_studymedicine.diagnostic_testbiologyCytogeneticsKaryotypeCell BiologyFlow Cytometrymedicine.diseaseMicroscopy ElectronKaryotypingbiology.proteinCancer researchChondrosarcomaFluorescence in situ hybridizationLaboratory Investigation
researchProduct

Verbesserte Orts- und Kontrastauflösung in der Ultraschalldiagnostik durch Nutzung Harmonischer Frequenzen

2001

Background: The aim of new techniques in head and neck sonography is to increase the sensitivity and the specificity of the examination, With tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) new techniques are available which allow increased contrast and resolution in head and neck sonography as well as a better detection of small blood vessels. Methods: We studied whether these techniques improve sonographic detection of head and neck lymph nodes and primary tumours of the upper aerodigestive tract. Results: The results indicate that THI allows a better detection of cervical lymph nodes. Furthermore, intranodal structures and the borders of the lymph node can be better det…

medicine.medical_specialtyPathologybusiness.industrySecond-harmonic imaging microscopymedicine.anatomical_structureUpper aerodigestive tractOtorhinolaryngologyEpidermoid carcinomaCervical lymph nodesMedicineRadiologyLymphbusinessHead and neckLymph nodeTumour statusLaryngo-Rhino-Otologie
researchProduct

Pentobarbital-sensitive EDHF comediates ACh-induced arteriolar dilation in the hamster microcirculation

1999

It is unclear to what extent the endothelium-derived hyperpolarizing factor (EDHF) contributes to the control of microcirculatory blood flow in vivo. We analyzed, by intravital microscopy in hamster muscles, the potential role of EDHF along the vascular tree under stimulated (ACh) or basal conditions. Experiments were performed in conscious as well as anesthetized (pentobarbital, urethan) animals. Additionally, cellular effects of the potential EDHF were studied in isolated small arteries. In pentobarbital-anesthetized animals, treatment with N ω-nitro-l-arginine (l-NNA; 30 μmol/l) and indomethacin (3 μmol/l) reduced the dilation in response to 10 μmol/l ACh from 60 ± 6 to 20 ± 4%. This ni…

medicine.medical_specialtyPentobarbitalEndothelium-derived hyperpolarizing factorPotassium ChannelsCharybdotoxinPhysiologyVasodilator AgentsIndomethacinHamsterVasodilationNitroarginineMuscle Smooth VascularMicrocirculationGlibenclamideBiological FactorsCytochrome P-450 Enzyme SystemArterioleCricetinaePhysiology (medical)Internal medicinemedicine.arterymedicineAnimalsCyclooxygenase InhibitorsMuscle SkeletalPentobarbitalSkinMesocricetusChemistryMicrocirculationPenicillamineAcetylcholineArteriolesEndocrinologyAnesthesiaFatty Acids UnsaturatedPotassiumEndothelium VascularCardiology and Cardiovascular MedicineIntravital microscopyAdjuvants Anesthesiamedicine.drugAmerican Journal of Physiology-Heart and Circulatory Physiology
researchProduct

Regulation of the human bradykinin B2 receptor expressed in sf21 insect cells: A possible role for tyrosine kinases

2000

The functional regulation of the human bradykinin B2 receptor expressed in sf21 cells was studied. Human bradykinin B2 receptors were immunodetected as a band of 75–80 kDa in membranes from recombinant baculovirus-infected cells and visualized at the plasma membrane, by confocal microscopy, using an antibody against an epitope from its second extracellular loop. B2 receptors, detected in membranes by [3H-bradykinin] binding, showed a Kd of 0.66 nmol/L and an expression level of 2.57 pmol/mg of protein at 54 h postinfection. In these cells, bradykinin induced a transient increase of intracellular calcium ([Ca2+]i) in fura 2-AM loaded sf21 cells, and promoted [35S]-GTPγS binding to membranes.…

medicine.medical_specialtyReceptor Bradykinin B2G proteinGene Expressionchemistry.chemical_elementBradykininReceptors Cell SurfaceSpodopteraCalciumBiologyBradykininBiochemistryCalcium in biologychemistry.chemical_compoundGTP-Binding ProteinsInternal medicineHomologous desensitizationmedicineAnimalsHumansPhosphorylationBradykinin receptorPhosphoamino AcidsReceptorOctopamineMolecular BiologyBradykinin Receptor AntagonistsCells CulturedMicroscopy ConfocalReceptors BradykininCell MembraneCell BiologyProtein-Tyrosine KinasesTyrphostinsGenisteinMolecular biologyRecombinant ProteinsEndocrinologychemistryGuanosine 5'-O-(3-Thiotriphosphate)ThapsigarginCalciumBaculoviridaeTyrosine kinaseProtein BindingJournal of Cellular Biochemistry
researchProduct

Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik

2005

Purpose To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. Materials and methods Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using …

medicine.medical_specialtyShort axisVentricular functionmedicine.diagnostic_testbusiness.industryPhase contrast microscopySignificant differenceMagnetic resonance imagingBlood flowlaw.inventionSurgeryVolume (thermodynamics)Flow (mathematics)Paired sampleslawmedicine.arteryAscending aortaLeft ventricular Stroke volumeMedicineRadiology Nuclear Medicine and imagingSystolebusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct