Search results for "Mitomycin"
showing 8 items of 48 documents
2017
Purpose Intraocular pressure (IOP) fluctuation is considered as a risk factor for glaucoma progression. We investigated IOP values and IOP fluctuation before and after trabeculectomy (TE) with mitomycin C (MMC) measured by 48-hour diurnal-nocturnal-IOP-profiles (DNP). Methods Pre- and postoperative DNPs of 92 eyes undergoing primary TE with MMC were analysed. Each 48-hour IOP-profile involved 10 IOP measurements (8:00 a.m., 2:00 p.m., 6:00 p.m., and 9:00 p.m. in sitting and at 00:00 in supine position). The “preoperative DNP” was performed a few weeks before TE. The “postoperative DNP” was performed at least six months (range: 6 months—2 years) after TE. Mean IOP values and IOP fluctuations…
Response to Letter to the Editor: Outcome of Bleb Revision With Autologous Conjunctival Graft Alone or Combined With Donor Scleral Graft for Late-ons…
2021
Re: Urinary pH is Highly Associated With Tumor Recurrence During Intravesical Mitomycin C Therapy for Nonmuscle Invasive Bladder Tumor
2011
Cytoreductive surgery and mitomycin C hyperthermic intraperitoneal chemotherapy with CO2 recirculation (HIPEC-CO2) for colorectal cancer peritoneal m…
2021
Peritoneal dissemination from colorectal cancer (CRC) has long been associated with unfavorable prognosis. However, in the last decades, the combination of cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) was able to obtain up to 30% 5-year survival rate in selected centers. Despite the wide diffusion of CRS and HIPEC, until now, there are no clear recommendations on the drug of choice for HIPEC nor its technique, and safety and efficacy data of HIPEC regimens and techniques are lacking. We performed a retrospective analysis of a prospectively maintained database of 26 CRS and mitomycin C HIPEC with CO2 recirculation (HIPEC-CO2) for CRC peritoneal metastasis…
Fluorescent in situ hybridization (FISH): A useful diagnostic tool for childhood conjunctival melanoma
2021
Introduction: Conjunctival melanoma is extremely rare in children and has low rates of resolution. Definitive histopathological diagnosis based exclusively on microscopic findings is sometimes difficult. Thus, early diagnosis and adequate treatment are essential to improve clinical outcomes. Clinical case: We present the first case in which the fluorescent in situ hybridization (FISH) diagnostic technique was applied to a 10-year-old boy initially suspected of having amelanotic nevi in his right eye. Based on the 65% of tumor cells with 11q13 (CCND1) copy number gain and 33% with 6p25 (RREB1) gain as measured by the FISH analysis, and on supporting histopathological findings, the diagnosis …
Results of conservative treatment (transurethral resection plus adjuvant intravesical chemotherapy) in patients with primary T1, G3 transitional cell…
1996
Objectives. To evaluate a selected population of 50 consecutive patients with primary T1, G3 bladder transitional cell carcinoma in the absence of carcinoma in situ (Tis) treated with a bladder-sparing approach. Methods. Between January 1983 and December 1992, all patients were treated by transurethral resection (TUR) plus adjuvant intravesical chemotherapy over 1 year. In most cases, doxorubicin, epirubicin, and mitomycin were used alone or in combination. Results. At a mean follow-up period of 52 months (range, 18 to 126), 16 of 50 patients (32%) showed a recurrent superficial tumor. The recurrent lesion was of Stage T1 in 11 (22%) cases, but was a T1, G3 tumor only in 5 cases (10%). In 2…
Mitomycin C bei oberflächlichen Hornhautablationen mit dem Excimer-Laser: Eigene Erfahrungen und Literaturübersicht
2005
Haze formation with loss of corneal transparency and surface irregularities and myopic regression are the major complications after corneal refractive surface surgery. The use of mitomycin C (MMC) with its antibiotic and antineoplastic properties is intended to inhibit wound healing mechanisms leading to subepithelial fibrosis. We report the use of MMC to achieve visual rehabilitation in the re-treatment of 3 eyes of 2 patients following refractive corneal surgery. According to the literature, the local use of MMC 0.02 % for 2 minutes is safe and enables one to treat and prevent stromal haze and myopic regression and allows a reduction of the postoperative topical pharmacotherapy. Results a…
Optical quality of hyperopic and myopic phakic intraocular lenses
2013
Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…