Search results for "Mitral"
showing 10 items of 146 documents
P2575Comparison of deep sedation with general anesthesia in patients undergoing percutaneous mitral valve repair (PMVR)
2018
Multiplane two-dimensional versus real time three-dimensional transesophageal echocardiography in ischemic mitral regurgitation
2011
OBJECTIVES: Intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) has been suggested to be a valuable technique for the evaluation of the mechanisms of ischemic mitral regurgitation (IMR). Studies comparing multiplane two-dimensional (2D) with 3D TEE reconstruction of the mitral valve using the new mitral valve quantification (MVQ) software are lacking. We undertook a prospective comparison between multiplane 2D and 3D TEE for the assessment of IMR. METHODS: We evaluated echocardiographically 45 patients with IMR who underwent mitral valve surgery in our institution. 2D and 3D TEE examinations followed by a 3D offline assessment of the mitral valve apparatus were perf…
On the Modeling of Transcatheter Therapies for the Aortic and Mitral Valves: A Review
2022
Transcatheter aortic valve replacement (TAVR) has become a milestone for the management of aortic stenosis in a growing number of patients who are unfavorable candidates for surgery. With the new generation of transcatheter heart valves (THV), the feasibility of transcatheter mitral valve replacement (TMVR) for degenerated mitral bioprostheses and failed annuloplasty rings has been demonstrated. In this setting, computational simulations are modernizing the preoperative planning of transcatheter heart valve interventions by predicting the outcome of the bioprosthesis interaction with the human host in a patient-specific fashion. However, computational modeling needs to carry out increasingl…
“Handbook” per la valutazione preoperatoria con CardioRM dei pazienti con insufficienza mitralica post-ischemica.
2010
Impatto dell'insufficienza mitralica funzionale sulla prognosi dei pazienti affetti da cardiopatia ischemica
2015
Impact of Right Ventricular Dysfunction on Outcomes After Transcatheter Edge-to-Edge Repair for Secondary Mitral Regurgitation
2021
OBJECTIVES This study sought to assess the impact of right ventricular dysfunction (RVD) as defined by impaired right ventricular-to-pulmonary artery (RV-PA) coupling, on survival after edge-to-edge transcatheter mitral valve repair (TMVR) for severe secondary mitral regurgitation (SMR). BACKGROUND Conflicting data exist regarding the benefit of TMVR in severe SMR. A possible explanation could be differences in RVD. METHODS Using data from the EuroSMR (European Registry on Outcomes in Secondary Mitral Regurgitation) registry, this study compared the characteristics and outcomes of SMR patients undergoing TMVR, according to their RV-PA coupling, assessed by tricuspid annular plane systolic e…
Mitral Valve Repair Without Using Rings or Slings
1989
Reconstructive surgery of the mitral valve is still deemed superior to prosthetic replacement because of the lower operative risk as well as the fewer thromboembolic complications [1, 2]. Whereas closed or open commissurotomy of a stenosed mitral valve has been routine in the past and present [3], reconstructive measures for incompetent valves have been among those least often performed. The use of rigid or semi-flexible annular rings [4–9] has significantly contributed to progress in this field. However, these are not suitable for repair of all valvular lesions and undoubtedly have at least some of the negative features of prosthetic substitutes. We have therefore started a program of mitr…
Advanced Protocol for Three-Dimensional Transesophageal Echocardiography Guidance Implementing Real-Time Multiplanar Reconstruction for Transcatheter…
2019
Transcatheter direct annuloplasty has been introduced as a novel interventional treatment option for severe mitral valve regurgitation. Until now, only one direct annuloplasty device (Edwards Cardioband) has been commercially available, being implanted in more than 250 patients worldwide. Yet this procedure poses greater challenges regarding optimal fluoroscopic and echocardiographic guidance compared with edge-to-edge repair: correct localization and orientation of the anchors upon penetration into the fibrous mitral annulus tissue and the basal left ventricular myocardium are preconditions for an optimal result and essential to avoid damage of the neighboring structures (atrioventricular …
Feasibility of a MPR-based 3DTEE guidance protocol for transcatheter direct mitral valve annuloplasty.
2020
Objectives Several interventional approaches have been established for the treatment of severe mitral regurgitation (MR) in patients at elevated risk for surgery. Direct annuloplasty is a relatively novel option in transcatheter mitral valve repair dedicated to reverse pathology in specific subsets of MR. With regard to echocardiographic guidance, this procedure presents with higher efforts in comparison with edge-to-edge therapy to enable safe and exact positioning of the device's anchors; evidence on optimal peri-interventional imaging is sparse. We tested a specific 3D-echo-guidance protocol implementing single-beat multiplanar reconstruction (MPR) and evaluated its feasibility. Methods …
Simulation of left ventricular outflow tract (LVOT) obstruction in transcatheter mitral valve-in-ring replacement.
2020
Left ventricular outflow tract (LVOT) obstruction is a feared complication of transcatheter mitral valve replacement (TMVR). This procedure leads to an elongation of LVOT in the left ventricle (namely, the neoLVOT), ultimately portending hemodynamic impairment and death. This study sought to understand the biomechanical implications of LVOT obstruction in two patients who underwent TMVR as an "off-label" application of the Edwards SAPIEN 3 (S3) Ultra transcatheter heart valve (THV). A computational framework of TMVR was developed to assess the neoLVOT area and quantify the sub-aortic flow structure. We observed that the annuloplasty ring serves as the key anchor zone of S3 Ultra THV. A good…