Search results for "Modulus"
showing 10 items of 491 documents
Evaluation of viscoelastic constants of metallic materials by laser-ultrasonics at elevating temperature
2002
The main objective of this study is the determination of elastic moduli and viscosity coefficients of metals at elevating temperature up to melting point. More specifically, it involves the analysis of the propagation of acoustic waves generated and detected simultaneously by laser-ultrasonic for the measurement of longitudinal and shear velocities. This preliminary work primarily concerns Tin (Sn) metal known for its low melting point and attenuation coefficient.
The cage elasticity and under-field structure of concentrated magnetic colloids probed by small angle X-ray scattering
2013
International audience; In the present study we probe the bulk modulus and the structure of concentrated magnetic fluids by small angle X-ray scattering. The electrostatically stabilized nanoparticles experience a repulsive interparticle potential modulated by dipolar magnetic interactions. On the interparticle distance length scale, we show that nanoparticles are trapped under-field in oblate cages formed by their first neighbours. We propose a theoretical model of magnetostriction for the field-induced deformation of the cage. This model captures the anisotropic features of the experimentally observed scattering pattern on the local scale in these strongly interacting colloidal dispersions
Layer-dependent mechanical properties and enhanced plasticity in the van der Waals chromium trihalide magnets
2020
The mechanical properties of magnetic materials are instrumental for the development of the magnetoelastic theory and the optimization of strain-modulated magnetic devices. In particular, two-dimensional (2D) magnets hold promise to enlarge these concepts into the realm of low-dimensional physics and ultrathin devices. However, no experimental study on the intrinsic mechanical properties of the archetypal 2D magnet family of the chromium trihalides has thus far been performed. Here, we report the room temperature layer-dependent mechanical properties of atomically thin CrI3 and CrCl3, finding that bilayers of CrI3 and CrCl3 have Young's moduli of 62.1 GPa and 43.4 GPa, with the highest sust…
Electrically induced deformation of giant liposomes monitored by thickness shear mode resonators.
2006
Thickness shear mode resonators are capable of registering small changes in the thickness and viscoelastic properties of ultrathin films attached to their surface. It was found that it is possible to monitor the deformation of surface-bound giant liposomes by applying an electric field with small amplitudes. Changes in the apparent height of attached vesicles in the nanometer range were easily detected as a function of lipid composition. Increasing the bending modulus by adding cholesterol results in a significantly reduced deformation from 16.8 nm (5% cholesterol) down to 3.2 nm (20% cholesterol), rendering this new method a robust and sensitive tool to detect the bending elasticity of lip…
A New Sampling Method for Spleen Stiffness Measurement Based on Quantitative Acoustic Radiation Force Impulse Elastography for Noninvasive Assessment…
2014
In our study, we evaluated the feasibility of a new sampling method for splenic stiffness (SS) measurement by Quantitative Acoustic Radiation Force Impulse Elastography (Virtual Touch Tissue Quantification (VTTQ)).We measured SS in 54 patients with HCV-related cirrhosis of whom 28 with esophageal varices (EV), 27 with Chronic Hepatitis C (CHC) F1–F3, and 63 healthy controls. VTTQ-SS was significantly higher among cirrhotic patients with EV (3.37 m/s) in comparison with controls (2.19 m/s,P<0.001), CHC patients (2.37 m/s,P<0.001), and cirrhotic patients without EV (2.7 m/s,P<0.001). Moreover, VTTQ-SS was significantly higher among cirrhotic patients without EV in comparison with bot…
A preliminary study of hardness and modulus of elasticity in sheep mandibles submitted to distraction osteogenesis and low-level laser therapy
2011
Objectives: To investigate the quality of newly formed bone in sheep mandibles submitted to distraction osteogenesis and low-level laser therapy (LLLT), based on hardness and modulus of elasticity values. The ideal moment for laser application (during the latency/activation period vs. during the bone consolidation period) was also evaluated. Computed tomography imaging was used to assess relapse as a result of early device removal. Study design: Extraoral distraction devices were placed in five sheep so as to achieve 1.5 cm of lengthened bone in 60 days. Distraction devices were removed 50, 40, and 33 days after surgery. Four animals were treated with LLLT, at different times, and one was u…
Associations of physical activity intensities, impact intensities and osteogenic index with proximal femur bone traits among sedentary older adults
2021
Background Dynamic high-intensity physical activity is thought to be beneficial for older adults’ bone health. Traditional volume-based processing of accelerometer-measured physical activity data, quantified on a minute-per-minute basis, may average out sporadic high impact activity, whereas accelerometer data processing approaches based on identifying impacts can capture also these potentially beneficial short activity bursts. We investigated the associations between habitual physical activity and proximal femur bone traits among sedentary older adults utilizing three different numerical treatments of accelerometer-data to examine, if impact-based processing approaches are more suitable to…
In Vivo Strain Analysis of Dilated Ascending Thoracic Aorta by ECG-Gated CT Angiographic Imaging
2017
Accurate assessment of aortic extensibility is a requisite first step for elucidating the pathophysiology of an ascending thoracic aortic aneurysm (ATAA). This study aimed to develop a framework for the in vivo evaluation of the full-field distribution of the aortic wall strain by imaging analysis of electrocardiographic- (ECG) gated thoracic data of 34 patients with ATAA. Seven healthy controls (i.e., non-aneurysmal aorta) from patients who underwent ECG-gated CT angiography for coronary artery diseases were included for comparison. To evaluate the systolic function, ECG-gated computed tomography (CT) angiography was used to generate patient-specific geometric meshes of the ascending aorta…
Collagen-low molecular weight hyaluronic acid semi-interpenetrating network loaded with gelatin microspheres for cell and growth factor delivery for …
2015
Intervertebral disc (IVD) degeneration is one of the main causes of low back pain. Current surgical treatments are complex and generally do not fully restore spine mobility. Development of injectable extracellular matrix-based hydrogels offers an opportunity for minimally invasive treatment of IVD degeneration. Here we analyze a specific formulation of collagen-low molecular weight hyaluronic acid (LMW HA) semi-interpenetrating network (semi-IPN) loaded with gelatin microspheres as a potential material for tissue engineering of the inner part of the IVD, the nucleus pulposus (NP). The material displayed a gel-like behavior, it was easily injectable as demonstrated by suitable tests and did …
Prediction of bone mechanical properties using QUS and pQCT: study of the human distal radius.
2007
Abstract The objective was to compare the prediction of bone mechanical properties provided by axial transmission to that provided by peripheral quantitative computed tomography (pQCT) at the distal radius. The distal radius is the location for Colles’ fractures, a common osteoporosis related trauma situation. Measurements of the radial speed of sound were performed using three axial transmission devices: a commercial device (Sunlight Omnisense, 1.25 MHz), a bi-directional axial transmission prototype (1 MHz), both measuring the velocity of the first arriving signal (FAS), and a low frequency (200 kHz) device, measuring the velocity of a slower wave. Co-localized pQCT measurements of bone m…